The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry
Abstract
Background: Significant aortic regurgitation (AR) is rare following surgical aortic valve replacement and has been associated with worse outcome. Following transcatheter aortic valve implantation (TAVI), AR is common, but little is known about its determinants and its effect on clinical outcome. Objective: To evaluate early outcome and risk factors possibly associated with AR after TAVI. Methods: Data were analysed from 690 patients with severe aortic stenosis treated with TAVI enrolled in the prospective multicentre German transcatheter aortic valve interventions registry. The occurrence of AR was evaluated angiographically after device deployment and removal of the catheter and guidewire. Significant AR was defined as AR≥2/4. Results: The study population's mean age was 81.4±6.3 years and men represented 44%. The mean logistic Euroscore was 20.4±13.1%. Overall, 84% of patients received the Medtronic CoreValve system and 16% received the Edwards Sapien valve. Significant AR occurred in 119 patients (17.2%). Factors independently associated with significant AR were aortic valve area (adjusted OR=0.10), annulus measurement by transoesophageal echocardiography (adjusted OR=1.94), male gender (adjusted OR=1.80), cardiogenic shock (adjusted OR=1.94) and renal failure (adjusted OR=0.53). In-hospital death rates were significantly higher in patients with significant AR than in those with no/mild AR (15.1% vs 6.7%, OR=2.50, 95% CI 1.37 to 4.55), as were rates of low cardiac output (20% vs 4.4%) and respiratory failure (16.5% vs 7.1%). Using multivariate analysis, the presence of post-procedural AR≥2/4 remained a strong independent predictor of in-hospital death (adjusted OR=2.43, 95% CI 1.22 to 4.85). Conclusion: Significant AR after TAVI is common and is associated with increased in-hospital mortality. Long-term follow-up is critical to further define the impact of residual AR on clinical outcome. Until these data become available, every effort should be made to prevent and treat this complication.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transcatheter Aortic-Valve Implantation for Aortic Stenosis in Patients Who Cannot Undergo Surgery
Leon, M. B., Smith, C. R., Mack, M., Miller, D. C., Moses, J. W., Svensson, L. G., Tuzcu, E. M., Webb, J. G., Fontana, G. P., Makkar, R. R., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa1008232 · Cited by 7,205
Cribier, A., Eltchaninoff, H., Bash, A., Borenstein, N., Tron, C., Bauer, F., Derumeaux, G., Anselme, F., Laborde, F., & Leon, M. B. (2002) · Circulation · doi:10.1161/01.cir.0000047200.36165.b8 · Cited by 3,172
Webb, J. G., Pasupati, S., Humphries, K., Thompson, C., Altwegg, L., Moss, R., Sinhal, A., Carere, R. G., Munt, B., Ricci, D., et al. (2007) · Circulation · doi:10.1161/circulationaha.107.698258 · Cited by 1,016
Guidelines for reporting morbidity and mortality after cardiac valvular operations
Edmunds, L. H., Clark, R. E., Cohn, L. H., Grunkemeier, G. L., Miller, D. C., & Weisel, R. D. (1996) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(96)70055-7 · Cited by 1,000
Rodés-Cabau, J., Webb, J. G., Cheung, A., Ye, J., Dumont, E., Feindel, C. M., Osten, M., Natarajan, M. K., Velianou, J. L., Martucci, G., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.12.014 · Cited by 974
Grube, E., Schuler, G., Buellesfeld, L., Gerckens, U., Linke, A., Wenaweser, P., Sauren, B., Mohr, F.-W., Walther, T., Zickmann, B., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.04.047 · Cited by 959
Self-citationThomas, M., Schymik, G., Walther, T., Himbert, D., Lefèvre, T., Treede, H., Eggebrecht, H., Rubino, P., Michev, I., Lange, R., et al. (2010) · Circulation · doi:10.1161/circulationaha.109.907402 · Cited by 875
Self-citationLeft retrograde cardioangiography in acquired cardiac disease
Sellers, R. D., Levy, M. J., Amplatz, K., & Lillehei, C. W. (1964) · The American Journal of Cardiology · doi:10.1016/0002-9149(64)90027-x · Cited by 800
Grube, E., Laborde, J. C., Gerckens, U., Felderhoff, T., Sauren, B., Buellesfeld, L., Mueller, R., Menichelli, M., Schmidt, T., Zickmann, B., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.639450 · Cited by 655
Self-citationTransapical Minimally Invasive Aortic Valve Implantation: Multicenter Experience
Walther, T., Simon, P., Dewey, T., Wimmer-Greinecker, G., Falk, V., Kasimir, M. T., Doss, M., Borger, M. A., Schuler, G., Glogar, D., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.677237 · Cited by 618
Self-citationProsthesis-patient mismatch: definition, clinical impact, and prevention
Pibarot, P., & Dumesnil, J. G. (2006) · Heart · doi:10.1136/hrt.2005.067363 · Cited by 606
Transcatheter aortic valve implantation: first results from a multi-centre real-world registry
Zahn, R., Gerckens, U., Grube, E., Linke, A., Sievert, H., Eggebrecht, H., Hambrecht, R., Sack, S., Hauptmann, K. E., Richardt, G., et al. (2011) · European Heart Journal · doi:10.1093/eurheartj/ehq339 · Cited by 596
Self-citationTranscatheter Aortic Valve Implantation: Impact on Clinical and Valve-Related Outcomes
Webb, J. G., Altwegg, L., Boone, R. H., Cheung, A., Ye, J., Lichtenstein, S., Lee, M., Masson, J. B., Thompson, C., Moss, R., et al. (2009) · Circulation · doi:10.1161/circulationaha.108.837807 · Cited by 589
Noninvasive Evaluation of the Aortic Root With Multislice Computed Tomography
Tops, L. F., Wood, D. A., Delgado, V., Schuijf, J. D., Mayo, J. R., Pasupati, S., Lamers, F. P. L., van der Wall, E. E., Schalij, M. J., Webb, J. G., et al. (2008) · JACC: Cardiovascular Imaging · doi:10.1016/j.jcmg.2007.12.006 · Cited by 518
Multimodal Assessment of the Aortic Annulus Diameter
Messika-Zeitoun, D., Serfaty, J.-M., Brochet, E., Ducrocq, G., Lepage, L., Detaint, D., Hyafil, F., Himbert, D., Pasi, N., Laissy, J.-P., et al. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.06.063 · Cited by 422
Clavel, M.-A., Webb, J. G., Pibarot, P., Altwegg, L., Dumont, E., Thompson, C., De Larochellière, R., Doyle, D., Masson, J.-B., Bergeron, S., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.01.060 · Cited by 389
Determinants of Significant Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation
Détaint, D., Lepage, L., Himbert, D., Brochet, E., Messika-Zeitoun, D., Iung, B., & Vahanian, A. (2009) · JACC: Cardiovascular Interventions · doi:10.1016/j.jcin.2009.07.003 · Cited by 386
Ng, A. C. T., Delgado, V., van der Kley, F., Shanks, M., van de Veire, N. R. L., Bertini, M., Nucifora, G., van Bommel, R. J., Tops, L. F., de Weger, A., et al. (2010) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.109.885152 · Cited by 373
Grube, E., Buellesfeld, L., Mueller, R., Sauren, B., Zickmann, B., Nair, D., Beucher, H., Felderhoff, T., Iversen, S., & Gerckens, U. (2008) · Circulation: Cardiovascular Interventions · doi:10.1161/circinterventions.108.819839 · Cited by 352
Self-citationVahanian, A., Alfieri, O. R., Al-Attar, N., Antunes, M. J., Bax, J., Cormier, B., Cribier, A., De Jaegere, P., Fournial, G., Kappetein, A. P., et al. (2008) · European Journal of Cardio-Thoracic Surgery · doi:10.1016/j.ejcts.2008.04.039 · Cited by 305
Svensson, L. G., Dewey, T., Kapadia, S., Roselli, E. E., Stewart, A., Williams, M., Anderson, W. N., Brown, D., Leon, M., Lytle, B., et al. (2008) · The Annals of Thoracic Surgery · doi:10.1016/j.athoracsur.2008.04.049 · Cited by 278
Sherif, M. A., Abdel-Wahab, M., Stöcker, B., Geist, V., Richardt, D., Tölg, R., & Richardt, G. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.035 · Cited by 258
Self-citationIs It Reasonable to Treat All Calcified Stenotic Aortic Valves With a Valved Stent?
Zegdi, R., Ciobotaru, V., Noghin, M., Sleilaty, G., Lafont, A., Latrémouille, C., Deloche, A., & Fabiani, J.-N. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.10.023 · Cited by 245
Percutaneous transarterial aortic valve implantation: what do we know?
Webb, J., & Cribier, A. G. (2010) · European Heart Journal · doi:10.1093/eurheartj/ehq453 · Cited by 154
Roques, F., Nashef, S. A. M., & Michel, P. (2001) · PubMed · Cited by 138
Sherif, M., Abdel‐Wahab, M., Beurich, H.-W., Stöcker, B., Zachow, D., Geist, V., Tölg, R., & Richardt, G. (2011) · EuroIntervention · doi:10.4244/eijv7i8a12 · Cited by 98
Self-citationParavalvular regurgitation one year after transcatheter aortic valve implantation
Rajani, R., Kakad, M., Khawaja, M. Z., Lee, L. S., James, R., Saha, M., & Hildick‐Smith, D. (2009) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.22399 · Cited by 81
de Jaegere, P. P. T. H., Piazza, N., Galema, T. W., Otten, A. M., Soliman, O. I. I., van Dalen, B. M., Geleijnse, M. L., Kappetein, A. P., García, H. G., van Es, G., et al. (2008) · EuroIntervention · doi:10.4244/eijv4i3a63 · Cited by 55
Leaks and the “Great ship” TAVI
Block, P. C. (2010) · Catheterization and Cardiovascular Interventions · doi:10.1002/ccd.22581 · Cited by 24
Correlates of Valvular Ossification in Patients with Aortic Valve Stenosis
Ing, S. W., Mohler, E. R., Putt, M. E., Torigian, D. A., & Leonard, M. B. (2009) · Clinical and Translational Science · doi:10.1111/j.1752-8062.2009.00168.x · Cited by 11
Cited by
Two-Year Outcomes after Transcatheter or Surgical Aortic-Valve Replacement
Kodali, S. K., Williams, M. R., Smith, C. R., Svensson, L. G., Webb, J. G., Makkar, R. R., Fontana, G. P., Dewey, T. M., Thourani, V. H., Pichard, A. D., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1200384 · Cited by 2,282
Mack, M. J., Leon, M. B., Smith, C. R., Miller, D. C., Moses, J. W., Tuzcu, E. M., Webb, J. G., Douglas, P. S., Anderson, W. N., Blackstone, E. H., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(15)60308-7 · Cited by 1,739
Transcatheter Aortic-Valve Replacement for Inoperable Severe Aortic Stenosis
Makkar, R. R., Fontana, G. P., Jilaihawi, H., Kapadia, S., Pichard, A. D., Douglas, P. S., Thourani, V. H., Babaliaros, V. C., Webb, J. G., Herrmann, H. C., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1202277 · Cited by 1,342
2012 ACCF/AATS/SCAI/STS Expert Consensus Document on Transcatheter Aortic Valve Replacement
Holmes, D. R., Mack, M. J., Kaul, S., Agnihotri, A., Alexander, K. P., Bailey, S. R., Calhoon, J. H., Carabello, B. A., Desai, M. Y., Edwards, F. H., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.01.001 · Cited by 749
Abdel-Wahab, M., Mehilli, J., Frerker, C., Neumann, F.-J., Kurz, T., Tölg, R., Zachow, D., Guerra, E., Massberg, S., Schäfer, U., et al. (2014) · JAMA · doi:10.1001/jama.2014.3316 · Cited by 686
Self-citation
Metadata
- Authors
- Abdel-Wahab, M., Zahn, R., Horack, M., Gerckens, U., Schuler, G., Sievert, H., Eggebrecht, H., Senges, J., Richardt, G., & for the German transcatheter aortic valve interventions registry investigators
- Venue
- Heart
- Publisher
- BMJ
- Published
- 2011-03-12
- Volume
- 97
- Issue
- 11
- Pages
- 899-906
- ISSN
- 1355-6037 (ISSN-L)
- 1468-201X
- OpenAlex
- W2102352001
- Cited by
- 474
- References
- 30
- FWCI
- 50.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.