Effect of order of draw of blood samples during phlebotomy on routine biochemistry results: Table 1
The DOI matches its Crossref record, with a small difference in title or year; 10 of the 11 references it cites were found in a registry or an index.
Abstract
Aim: To investigate whether incorrect order of draw of blood samples during phlebotomy causes in vitro potassium ethylenediaminetetraacetic acid EDTA (kEDTA) contamination of blood samples. Methods: Serum kEDTA, potassium, calcium, magnesium, alkaline phosphatase, zinc and iron concentrations were measured in blood samples drawn before and after collecting blood into kEDTA containing sample tubes by an experienced phlebotomist using the Sarstedt Safety Monovette system. Results: EDTA was undetectable in all samples. The concentrations of other analytes were similar in blood samples drawn before and after collection of the EDTA blood sample. Conclusion: Order of draw of blood samples using the Sarstedt Safety Monovette system has no effect on serum biochemistry results, when samples are taken by an experienced phlebotomist.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Spurious hyperkalaemia due to EDTA contamination: common and not always easy to identify
Cornes, M. P., Ford, C., & Gama, R. (2008) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2008.007241 · Cited by 69
Self-citationSharratt, C. L., Gilbert, C. J., Cornes, M. C., Ford, C., & Gama, R. (2009) · International Journal of Clinical Practice · doi:10.1111/j.1742-1241.2008.01981.x · Cited by 66
Self-citationRecommended "order of draw" for collecting blood specimens into additive-containing tubes.
Calam, R. R., & Cooper, M. H. (1982) · Clinical Chemistry · doi:10.1093/clinchem/28.6.1399 · Cited by 47
Multi-centre observational study of spurious hyperkalaemia due to EDTA contamination.
Cornes, M. P., Davidson, F., Darwin, L., Gay, C., Redpath, M., Waldron, J. L., Ford, C., & Gama, R. M. (2010) · PubMed · Cited by 29
Self-citationEDTA analysis on the Roche MODULAR® analyser
Davidson, D. F. (2007) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/000456307780480846 · Cited by 24
Combined False Hyperkalemia and Hypocalcemia Due to Specimen Contamination During Routine Phlebotomy
NAGUIB, T. M., & EVANS, N. (2002) · Southern Medical Journal · doi:10.1097/00007611-200295100-00025 · Cited by 22
Majid, A., Heaney, D. C., Padmanabhan, N. V. D. M. N., & Spooner, R. (1996) · Journal of Clinical Pathology · doi:10.1136/jcp.49.12.1019 · Cited by 16
Mitigation and detection of spurious potassium and sodium results
Sulaiman, R. A., Twomey, P. J., & Gama, R. M. (2010) · Clinica Chimica Acta · doi:10.1016/j.cca.2010.08.028 · Cited by 14
Self-citationAvoiding spurious hyperkalaemia
Gama, R. M., Cornes, M. P., & Ford, C. (2009) · BMJ · doi:10.1136/bmj.b4823 · Cited by 8
Self-citationA case of hyperkalaemia associated with hypocalcaemia
Stevens, R. J. G., Laina, V., Wong, C., & Coulson, C. E. (2008) · Emergency Medicine Journal · doi:10.1136/emj.2007.056903 · Cited by 7
Research works printed but not linked: 1
- 10.1097/00007611-200210000-00024 · doi:10.1097/00007611-200210000-00024
Cited by
Joint EFLM-COLABIOCLI Recommendation for venous blood sampling
Simundic, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimaraes, J. T., et al. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0602 · Cited by 240
Self-citationPreanalytical Variables Affecting the Integrity of Human Biospecimens in Biobanking
Ellervik, C., & Vaught, J. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2014.228783 · Cited by 167
Lippi, G., Banfi, G., Church, S., Cornes, M., De Carli, G., Grankvist, K., Kristensen, G. B., Ibarz, M., Panteghini, M., Plebani, M., et al. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-1051 · Cited by 151
Self-citationBlood venous sample collection: Recommendations overview and a checklist to improve quality
Giavarina, D., & Lippi, G. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.02.021 · Cited by 136
Phlebotomy, a bridge between laboratory and patient
Ialongo, C., & Bernardini, S. (2016) · Biochemia Medica · doi:10.11613/bm.2016.002 · Cited by 97
“tube order does not affect the blood testing (109,110).”
Cornes, M., van Dongen-Lases, E., Grankvist, K., Ibarz, M., Kristensen, G., Lippi, G., Nybo, M., & Simundic, A.-M. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0426 · Cited by 92
Self-citationPseudohyperkalemia: A new twist on an old phenomenon
Meng, Q. H., & Wagar, E. A. (2014) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408363.2014.966898 · Cited by 83
Cornes, M. P., Church, S., van Dongen-Lases, E., Grankvist, K., Guimarães, J. T., Ibarz, M., Kovalevskaya, S., Kristensen, G. B., Lippi, G., Nybo, M., et al. (2016) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1177/0004563216643969 · Cited by 43
Self-citationHumann‐Ziehank, E., & Ganter, M. (2012) · animal · doi:10.1017/s1751731111002679 · Cited by 41
Incorrect order of draw could be mitigate the patient safety: a phlebotomy management case report
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2013) · Biochemia Medica · doi:10.11613/bm.2013.026 · Cited by 33
“potassium, magnesium, alkaline phosphatase, and iron), when closed system for blood collection from Sarstedt or BD were used (17,18).”
MethodThe Order of Draw during Blood Collection: A Systematic Literature Review
Bazzano, G., Galazzi, A., Giusti, G. D., Panigada, M., & Laquintana, D. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18041568 · Cited by 24
Relevance of EDTA carryover during blood collection
Cadamuro, J., Felder, T. K., Oberkofler, H., Mrazek, C., Wiedemann, H., & Haschke‐Becher, E. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0944 · Cited by 26
Lima-Oliveira, G., Brennan-Bourdon, L. M., Varela, B., Arredondo, M. E., Aranda, E., Flores, S., & Zamora, S. P. O. (2020) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2020.1849008 · Cited by 29
Erroneous potassium results: preanalytical causes, detection, and corrective actions
Schlüter, K., & Cadamuro, J. (2023) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2023.2195936 · Cited by 26
Lima-Oliveira, G., Salvagno, G. L., Danese, E., Brocco, G., Guidi, G. C., & Lippi, G. (2014) · Biochemia Medica · doi:10.11613/bm.2014.038 · Cited by 21
McKeeman, G. C., Hall, S. L., & Freedman, D. B. (2019) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563219888541 · Cited by 22
Incorrect order of draw of blood samples does not cause potassium EDTA sample contamination
Cornes, M. P., Sulaiman, R. A., Whitehead, S. J., Othonos, N., Ford, C., & Gama, R. M. (2012) · British Journal of Biomedical Science · doi:10.1080/09674845.2012.12069141 · Cited by 22
Self-citationkEDTA Sample Contamination: A Reappraisal
Chadwick, K., Whitehead, S. J., Ford, C., & Gama, R. M. (2019) · The Journal of Applied Laboratory Medicine · doi:10.1373/jalm.2018.027920 · Cited by 20
Self-citationCai, Q., Zhou, Y., & Yang, D. (2017) · Biochemia Medica · doi:10.11613/bm.2018.010703 · Cited by 14
The order of draw: much ado about nothing?
Indevuyst, C., Schuermans, W., Bailleul, E., & Meeus, M. (2014) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12230 · Cited by 13
Pseudohyperkalemia in Serum and Plasma: The Phenomena and Its Clinical Implications
Mahto, M., Kumar, M., Kumar, S., & Banerjee, A. (2020) · Indian Journal of Clinical Biochemistry · doi:10.1007/s12291-020-00889-3 · Cited by 12
Ercan, Ş., Ramadan, B., & Gerenli, O. (2021) · Biochemia Medica · doi:10.11613/bm.2021.020704 · Cited by 13
Standard-Arbeitsanleitung zur peripher venösen Blutentnahme für die labormedizinische Diagnostik
Meyer, A., Cadamuro, J., Streichert, T., Gurr, E., Fiedler, M., Leichtle, A. B., Petersmann, A., Pick, K.-H., Orth, M., Risch, L., et al. (2017) · Journal of Laboratory Medicine · doi:10.1515/labmed-2017-0127 · Cited by 21
Heparin and citrate additive carryover during blood collection
Keppel, M. H., Auer, S., Lippi, G., Meyer, A., Cornes, M. P., Felder, T. K., Oberkofler, H., Mrazek, C., Haschke‐Becher, E., & Cadamuro, J. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-0433 · Cited by 10
Self-citationKalaria, T., Ford, C., & Gama, R. M. (2022) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/00045632221140989 · Cited by 9
Self-citationPreanalytical investigations of phlebotomy: methodological aspects, pitfalls and recommendations
Ialongo, C., & Bernardini, S. (2017) · Biochemia Medica · doi:10.11613/bm.2017.020 · Cited by 12
The order of draw, myth or science
Cornes, M. P., Ford, C., & Gama, R. M. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0650 · Cited by 8
Self-citationCase report of unexplained hypocalcaemia in a slightly haemolysed sample
Cornes, M. (2017) · Biochemia Medica · doi:10.11613/bm.2017.046 · Cited by 7
Self-citationWinter, W. E., Pittman, D. L., & Harris, N. (2022) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2022.11.012 · Cited by 10
Sample processing and specimen misidentification issues
Woodworth, A. L., & Pyle‐Eilola, A. L. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-813776-5.00003-0 · Cited by 6
Preanalytical potassium EDTA sample contamination: open versus closed phlebotomy systems
Asif, U., Whitehead, S. J., Ford, C., & Gama, R. M. (2019) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563219878463 · Cited by 9
Self-citationStonys, R., & Vitkus, D. (2024) · Biochemia Medica · doi:10.11613/bm.2024.020702 · Cited by 6
Sample Processing and Specimen Misidentification Issues
Woodworth, A. L., & Pyle, A. L. (2013) · Elsevier eBooks · doi:10.1016/b978-0-12-415783-5.00004-9 · Cited by 7
Baskin, L. B., Dias, V., Chin, A., Abdullah, A., & Naugler, C. T. (2013) · Elsevier eBooks · doi:10.1016/b978-0-12-415783-5.00003-7 · Cited by 4
Wspólne zalecenia EFLM-COLABIOCLI dotyczące pobierania krwi żylnej
Šimundić, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimarães, J. T., et al. (2019) · Diagnostyka Laboratoryjna · doi:10.5604/01.3001.0013.7785 · Cited by 2
Self-citationErrors in patient preparation, specimen collection, anticoagulant and preservative use
Baskin, L. B., Chin, A., Abdullah, A., & Naugler, C. T. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-813776-5.00002-9 · Cited by 3
Unexpected abnormal coagulation test results in a 2-year-old child: A case report
Radovanović, P. B., Mikulčić, T. Ž., & Medica, J. S. (2019) · Biochemia Medica · doi:10.11613/bm.2020.011002 · Cited by 1
A survey of order of draw on inpatient wards and adherence to EFLM-COLABIOCLI recommendations
Hepburn, S. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2020-0202 · Cited by 1
Kalaria, T., Ford, C., & Gama, R. M. (2022) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/00045632221134190 · Cited by 2
Self-citationYeates, R. L. (2016) · ResearchOnline at James Cook University (James Cook University) · doi:10.25903/s7je-hm44 · Cited by 1
Joint EFLM-COLABIOCLI recommendation for venous blood sampling - v 1.1, June 2018
Šimundić, A.-M., Bölenius, K., Cadamuro, J., Church, S., Cornes, M. P., van Dongen-Lases, E. C., Eker, P., Erdeljanovic, T., Grankvist, K., Guimarães, J. T., et al. (2024) · Revista română de medicină de laborator · doi:10.2478/rrlm-2024-0004 · Cited by 2
Self-citation
Metadata
- Authors
- Sulaiman, R. A., Cornes, M. P., Whitehead, S. J., Othonos, N., Ford, C., & Gama, R.
- Affiliations
- University Hospitals Birmingham NHS Foundation Trust (GB)
- New Cross Hospital (GB)
- University of Wolverhampton (GB)
- Corresponding author
- Sulaiman, Raashda A
- Venue
- Journal of Clinical Pathology
- Publisher
- BMJ
- Published
- 2011-07-21
- Volume
- 64
- Issue
- 11
- Pages
- 1019-1020
- ISSN
- 0021-9746 (ISSN-L)
- 1472-4146
- OpenAlex
- W1999512448
- Semantic Scholar
- d5d0700b47b3b3329a38db321a460909ab0a4dd1
- Cited by
- 40
- References
- 11
- Citations by year
- 2024: 2 · 2023: 1 · 2022: 3 · 2021: 2 · 2020: 3 · 2019: 8 · 2018: 1 · 2017: 5 · 2016: 3 · 2015: 2 · 2014: 4 · 2013: 4 · 2012: 2
- FWCI
- 2.18
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Clinical Pathology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Health Sciences › Medicine › Microbiology (medical) › Bacterial Identification and Susceptibility Testing
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical chemistry methods development
- Keywords
- phlebotomy, serum biochemistry, potassium, calcium, magnesium, alkaline phosphatase, zinc, iron
- MeSH terms
- Adolescent, Adult, Alkaline Phosphatase, Calcium, Edetic Acid, Humans, Iron, Magnesium, Middle Aged, Posture, Potassium, Zinc, Phlebotomy, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.