Laboratory assessment of vitamin B12 status
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The detection and correction of vitamin B 12 (B 12) deficiency prevents megaloblastic anaemia and potentially irreversible neuropathy and neuropsychiatric changes. B 12 status is commonly estimated using the abundance of the vitamin in serum, with ∼148 pmol/L (200 ng/L) typically set as the threshold for diagnosing deficiency. Serum B 12 assays measure the sum of haptocorrin-bound and transcobalamin-bound (known as holotranscobalamin) B 12. It is only holotranscobalamin that is taken up by cells to meet metabolic demand. Although receiver operator characteristic curves show holotranscobalamin measurement to be a moderately more reliable marker of B 12 status than serum B 12, both assays have an indeterminate range. Biochemical evidence of metabolic abnormalities consistent with B 12 insufficiency is frequently detected despite an apparently sufficient abundance of the vitamin. Laboratory B 12 status markers that reflect cellular utilisation rather than abundance are available. Two forms of B 12 act as coenzymes for two different reactions. Methionine synthase requires methylcobalamin for the remethylation of methionine from homocysteine. A homocysteine concentration >20 µmol/L may suggest B 12 deficiency in folate-replete patients. In the second B 12-dependent reaction, methylmalonyl-CoA mutase uses adenosylcobalamin to convert methylmalonyl-CoA to succinyl-CoA. In B 12 deficiency excess methylmalonyl-CoA is hydrolysed to methylmalonic acid. A serum concentration >280 nmol/L may suggest suboptimal status in young patients with normal renal function. No single laboratory marker is suitable for the assessment of B 12 status in all patients. Sequential assay selection algorithms or the combination of multiple markers into a single diagnostic indicator are both approaches that can be used to mitigate inherent limitations of each marker when used independently.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stabler, S. P. (2013) · New England Journal of Medicine · doi:10.1056/nejmcp1113996 · Cited by 1,224
Facts and recommendations about total homocysteine determinations: an expert opinion
Refsum, H., Smith, A. D., Ueland, P. M., Nexo, E., Clarke, R., McPartlin, J., Johnston, C., Engbaek, F., Schneede, J., McPartlin, C., et al. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2003.021634 · Cited by 1,056
Hunt, A., Harrington, D., & Robinson, S. (2014) · BMJ · doi:10.1136/bmj.g5226 · Cited by 406
Self-citationJapanese 2011 guidelines for prevention and treatment of osteoporosis—executive summary
Orimo, H., Nakamura, T., Hosoi, T., Iki, M., Uenishi, K., Endo, N., Ohta, H., Shiraki, M., Sugimoto, T., Suzuki, T., et al. (2012) · Archives of Osteoporosis · doi:10.1007/s11657-012-0109-9 · Cited by 358
Vitamin K Nutrition and Osteoporosis
Binkley, N. C., & Suttie, J. W. (1995) · The Journal of Nutrition · doi:10.1093/jn/125.7.1812 · Cited by 185
Fedosov, S. N., Brito, A., Miller, J. W., Green, R., & Allen, L. H. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0818 · Cited by 184
Torgerson, D. J. (2018) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2018.1127 · Cited by 20
Cited by
Berger, M. M., Shenkin, A., Schweinlin, A., Amrein, K., Augsburger, M., Biesalski, H.-K., Bischoff, S. C., Casaer, M. P., Gundogan, K., Lepp, H.-L., et al. (2022) · Clinical Nutrition · doi:10.1016/j.clnu.2022.02.015 · Cited by 615
Nutritional Recommendations for Adult Bariatric Surgery Patients: Clinical Practice
Sherf Dagan, S., Goldenshluger, A., Globus, I., Schweiger, C., Kessler, Y., Kowen Sandbank, G., Ben-Porat, T., & Sinai, T. (2017) · Advances in Nutrition · doi:10.3945/an.116.014258 · Cited by 348
O'Kane, M., Parretti, H. M., Pinkney, J., Welbourn, R., Hughes, C. A., Mok, J., Walker, N., Thomas, D., Devin, J., Coulman, K. D., et al. (2020) · Obesity Reviews · doi:10.1111/obr.13087 · Cited by 338
Mladěnka, P., Macáková, K., Kujovská Krčmová, L., Javorská, L., Mrštná, K., Carazo, A., Protti, M., Remião, F., Nováková, L., & collaborators, T. O. R. A. (2022) · Nutrition Reviews · doi:10.1093/nutrit/nuab061 · Cited by 262
Homocysteine: Its Possible Emerging Role in At-Risk Population Groups
Azzini, E., Ruggeri, S., & Polito, A. (2020) · International Journal of Molecular Sciences · doi:10.3390/ijms21041421 · Cited by 161
“Harrington [170] pointed out that “no single laboratory marker is suitable for the assessment of B12 status”, and holotranscobalamin can be a more reliable marker of B12 status than total vitamin B12 alone.”
Background
Metadata
- Authors
- Harrington, D. J.
- Venue
- Journal of Clinical Pathology
- Publisher
- BMJ
- Published
- 2016-05-11
- Volume
- 70
- Issue
- 2
- Pages
- 168-173
- ISSN
- 0021-9746 (ISSN-L)
- 1472-4146
- OpenAlex
- W2351559594
- Cited by
- 130
- References
- 7
- FWCI
- 7.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Laboratory assessment of vitamin B12 status. https://app.cochat.ai/papers/10.1136/jclinpath-2015-203502
- The paper
- Harrington, D. J. (2017). Laboratory assessment of vitamin B12 status. Journal of Clinical Pathology. https://doi.org/10.1136/jclinpath-2015-203502
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.