CoChat

Maternal sleep-disordered breathing and the risk of delivering small for gestational age infants: a prospective cohort study

Open access
Pamidi, Sushmita, Marc, Isabelle, Simoneau, Gabrielle, Lavigne, Lorraine, Olha, Allen, Benedetti, Andrea, Sériès, Frédéric, Fraser, William, Audibert, François, Bujold, Emmanuel, Gagnon, Robert, Schwartzman, Kevin, Kimoff, R John · 2016 · Thorax
Cited by 82

The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.

Abstract

OBJECTIVE: It is unclear whether objectively measured maternal sleep-disordered breathing (SDB) leads to poor fetal outcomes. In this study, we prospectively assessed whether polysomnography-based diagnosis of SDB in the third trimester is associated with the delivery of small for gestational age (SGA) infants. STUDY DESIGN: Participants were recruited from a multicentre pregnancy cohort study. Eligible participants were evaluated for SDB based on symptoms (snoring and/or witnessed apnoeas assessed using the Pittsburgh Sleep Quality Index questionnaire) and in-home complete polysomnography in the third trimester. SGA was defined as <10th centile using customised birthweight centiles adjusted for maternal parity, prepregnancy body mass index (BMI), ethnicity, gestational age and infant sex. RESULTS: Of the 234 pregnant participants who completed a sleep study, 82% were Caucasian, with mean (SD) age of 31 (4.3) years and a prepregnancy BMI of 23 (4) kg/m(2). The delivery of SGA infants occurred in 27 (12%) of the study participants. The symptoms of SDB had poor overall sensitivity and specificity for diagnosing SDB identified by polysomnography. Symptoms of SDB in the third trimester demonstrated a potential association with delivering an SGA infant, however this did not reach statistical significance (OR 2.36 (95% CI 0.85 to 6.54, p=0.10)). However, the odds of delivering an SGA infant were significantly increased with polysomnography-based diagnosis of maternal SDB (using apnoea-hypopnoea index cut-off of 10, OR 2.65 (95% CI 1.15 to 6.10, p=0.02)). CONCLUSIONS: Objectively measured SDB in the third trimester is significantly associated with the delivery of SGA infants.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1136/thoraxjnl-2015-208038

Cites

13 of 13 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 13 references

Cited by

See all 82

Metadata

Authors
Pamidi, S., Marc, I., Simoneau, G., Lavigne, L., Olha, A., Benedetti, A., Sériès, F., Fraser, W., Audibert, F., Bujold, E., Gagnon, R., Schwartzman, K., & Kimoff, R. J.
Venue
Thorax
Publisher
BMJ
Published
2016-04-15
Volume
71
Issue
8
Pages
719-725
ISSN
  • 0040-6376 (ISSN-L)
  • 1468-3296
OpenAlex
W2339336643
Cited by
82
References
13
FWCI
6.84
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Maternal sleep-disordered breathing and the risk of delivering small for gestational age infants: a prospective cohort study. https://app.cochat.ai/papers/10.1136/thoraxjnl-2015-208038
The paper
Pamidi, S., Marc, I., Simoneau, G., Lavigne, L., Olha, A., Benedetti, A., Sériès, F., Fraser, W., Audibert, F., Bujold, E., Gagnon, R., Schwartzman, K., & Kimoff, R. J. (2016). Maternal sleep-disordered breathing and the risk of delivering small for gestational age infants: a prospective cohort study. Thorax. https://doi.org/10.1136/thoraxjnl-2015-208038

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.