CoChat

Validation of a portable bioelectrical impedance analyzer for the assessment of body composition

Karelis, Antony D., Chamberland, Gabriel, Aubertin-Leheudre, Mylène, Duval, Christian, Ecological mobility in Aging and Parkinson (EMAP) group · 2013 · Applied Physiology, Nutrition, and Metabolism
Cited by 124

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

One of the major challenges in field research has been the difficulty to adequately measure body composition, such as % body fat and fat-free mass (FFM). Therefore, the purpose of the present study was to investigate the convergent validity of the portable bioelectrical impedance body composition analyzer, the Inbody 230, with dual X-ray absorptiometry (DXA) (General Electric Lunar Prodigy). The study population consisted of 145 men and women (age, 44.6 ± 20 years; BMI, 24.5 ± 3.8 kg·m–2). We measured body composition (fat mass, % body fat, total FFM, trunk FFM, and appendicular FFM) using DXA and the Inbody 230. Results show strong significant correlations between both methods for fat mass, % body fat, total FFM, and trunk FFM (r = 0.94–0.99). Furthermore, we showed a modest significant correlation between both methods for appendicular FFM (r = 0.63). Finally, as shown by Bland–Altman analysis, no significant biases were observed between Inbody 230 and DXA for fat mass, % body fat, and total FFM. However, trunk and appendicular FFM were shown to have significant biases between the Inbody 230 and DXA. In conclusion, the present study indicated that the portable Inbody 230 may be an acceptable device to measure fat mass, % body fat, and total FFM (except for women) in healthy adults. In addition, there appears to be a systematic bias for the estimation of trunk and appendicular FFM with the Inbody 230 in men and women.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1139/apnm-2012-0129

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 124

Metadata

Authors
Karelis, A. D., Chamberland, G., Aubertin-Leheudre, M., Duval, C., & Ecological mobility in Aging and Parkinson (EMAP) group
Venue
Applied Physiology, Nutrition, and Metabolism
Published
2013-01-01
Volume
38
Issue
1
Pages
27-32
ISSN
  • 1715-5312 (ISSN-L)
  • 1715-5320
OpenAlex
W2263961817
Cited by
124
References
5
FWCI
5.30
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validation of a portable bioelectrical impedance analyzer for the assessment of body composition. https://app.cochat.ai/papers/10.1139/apnm-2012-0129
The paper
Karelis, A. D., Chamberland, G., Aubertin-Leheudre, M., Duval, C., & Ecological mobility in Aging and Parkinson (EMAP) group. (2013). Validation of a portable bioelectrical impedance analyzer for the assessment of body composition. Applied Physiology, Nutrition, and Metabolism. https://doi.org/10.1139/apnm-2012-0129

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.