Continuous stress detection using a wrist device: in laboratory and real life
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Continuous exposure to stress is harmful for mental and physical health, but to combat stress, one should first detect it. In this paper we propose a method for continuous detection of stressful events using data provided from a commercial wrist device. The method consists of three machine-learning components: a laboratory stress detector that detects short-term stress every 2 minutes; an activity recognizer that continuously recognizes user's activity and thus provides context information; and a context-based stress detector that exploits the output of the laboratory stress detector and the user's context in order to provide the final decision on 20 minutes interval. The method was evaluated in a laboratory and a real-life setting. The accuracy on 55 days of real-life data, for a 2-class problem, was 92%. The method is currently being integrated in a smartphone application for managing mental health and well-being.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Psychological stress and the human immune system: a meta-analytic study of 30 Years of inquiry
Segerstrom, S. C., & Miller, G. E. (2004) · Psychological Bulletin · doi:10.1037/0033-2909.130.4.601 · Cited by 3,334
Spielberger, C. D. (2010) · The Corsini Encyclopedia of Psychology · doi:10.1002/9780470479216.corpsy0943 · Cited by 2,535 · cited 1×
“Four Short STAI-Y anxiety questionnaires [26] were filled by each participant: before the experiment (1), and after the easy (2), medium (3) and hard session (4).”
MethodDetecting Stress During Real-World Driving Tasks Using Physiological Sensors
Healey, J. A., & Picard, R. W. (2005) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2005.848368 · Cited by 2,207 · cited 4×
“The pioneers in this field are Healey and Picard who showed in 2005 that stress can be detected using physiological sensors [12].”
BackgroundMethodInfluentialStress Recognition Using Wearable Sensors and Mobile Phones
Sano, A., & Picard, R. W. (2013) · 2013 Humaine Association Conference on Affective Computing and Intelligent Interaction · doi:10.1109/acii.2013.117 · Cited by 523
Ecological momentary assessment research in behavioral medicine
Smyth, J. M., & Stone, A. A. (2003) · Journal of Happiness Studies · doi:10.1023/a:1023657221954 · Cited by 439 · cited 1×
“Real-life data For the real-life data we used a combination of stress log and Ecological Momentary Assessment (EMA) prompts [27] implemented on a smartphone.”
MethodCall Center Stress Recognition with Person-Specific Models
Hernandez, J., Morris, R. R., & Picard, R. W. (2011) · Lecture Notes in Computer Science · doi:10.1007/978-3-642-24600-5_16 · Cited by 210 · cited 2×
“As with many scientific problems, first the problem is analyzed in constrained environments, e.g., a laboratory [24], office [28], car (analysis while driving) [12], bed (analysis while sleeping) [17], and call center [13].”
BackgroundMethodThe overtraining syndrome in athletes: A stress-related disorder
Angeli, A., Minetto, M., Dovio, A., & Paccotti, P. (2004) · Journal of Endocrinological Investigation · doi:10.1007/bf03347487 · Cited by 169
COGCAM: Contact-free Measurement of Cognitive Stress During Computer Tasks with a Digital Camera
McDuff, D. J., Hernandez, J., Gontarek, S., & Picard, R. W. (2016) · Proceedings of the 2016 CHI Conference on Human Factors in Computing Systems · doi:10.1145/2858036.2858247 · Cited by 113 · cited 1×
“, analyzing the user’s audio or video [16, 2, 22]).”
BackgroundMonitoring the impact of stress on the sleep patterns of pilgrims using wearable sensors
Muaremi, A., Bexheti, A., Gravenhorst, F., Arnrich, B., & Troster, G. (2014) · IEEE-EMBS International Conference on Biomedical and Health Informatics (BHI) · doi:10.1109/bhi.2014.6864335 · Cited by 60
Cited by
Introducing WESAD, a Multimodal Dataset for Wearable Stress and Affect Detection
Schmidt, P., Reiss, A., Duerichen, R., Marberger, C., & Van Laerhoven, K. (2018) · Proceedings of the 20th ACM International Conference on Multimodal Interaction · doi:10.1145/3242969.3242985 · Cited by 1,277
Machine learning in mental health: a scoping review of methods and applications
Shatte, A. B. R., Hutchinson, D. M., & Teague, S. J. (2019) · Psychological Medicine · doi:10.1017/s0033291719000151 · Cited by 1,047
Outlook on human-centric manufacturing towards Industry 5.0
Lu, Y., Zheng, H., Chand, S., Xia, W., Liu, Z., Xu, X., Wang, L., Qin, Z., & Bao, J. (2022) · Journal of Manufacturing Systems · doi:10.1016/j.jmsy.2022.02.001 · Cited by 671
Stress detection in daily life scenarios using smart phones and wearable sensors: A survey
Can, Y. S., Arnrich, B., & Ersoy, C. (2019) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2019.103139 · Cited by 476
Thieme, A., Belgrave, D., & Doherty, G. (2020) · ACM Transactions on Computer-Human Interaction · doi:10.1145/3398069 · Cited by 406
“09010 [67] Martin Gjoreski, Hristijan Gjoreski, Mitja Luštrek, and Matjaž Gams.”
BackgroundMonitoring stress with a wrist device using context
Gjoreski, M., Luštrek, M., Gams, M., & Gjoreski, H. (2017) · Journal of Biomedical Informatics · doi:10.1016/j.jbi.2017.08.006 · Cited by 352
Self-citationCan, Y. S., Chalabianloo, N., Ekiz, D., & Ersoy, C. (2019) · Sensors · doi:10.3390/s19081849 · Cited by 349
Stress Detection with Machine Learning and Deep Learning using Multimodal Physiological Data
Bobade, P., & Vani, M. (2020) · 2020 Second International Conference on Inventive Research in Computing Applications (ICIRCA) · doi:10.1109/icirca48905.2020.9183244 · Cited by 301
Detecting Moments of Stress from Measurements of Wearable Physiological Sensors
Kyriakou, K., Resch, B., Sagl, G., Petutschnig, A., Werner, C., Niederseer, D., Liedlgruber, M., Wilhelm, F., Osborne, T., & Pykett, J. (2019) · Sensors · doi:10.3390/s19173805 · Cited by 239
Stress Detection in Working People
Sriramprakash, S., Prasanna, V. D., & Murthy, O. V. R. (2017) · Procedia Computer Science · doi:10.1016/j.procs.2017.09.090 · Cited by 172
Anxiety level recognition for virtual reality therapy system using physiological signals
Šalkevicius, J., Damaševičius, R., Maskeliunas, R., & Laukienė, I. (2019) · Electronics · doi:10.3390/electronics8091039 · Cited by 135
“[27] describes a continuous stress detection system, which used an Empatica wristband to physiological signals.”
BackgroundHuman stress classification during public speaking using physiological signals
Arsalan, A., & Majid, M. (2021) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2021.104377 · Cited by 77
Metadata
- Authors
- Gjoreski, M., Gjoreski, H., Luštrek, M., & Gams, M.
- Venue
- Proceedings of the 2016 ACM International Joint Conference on Pervasive and Ubiquitous Computing: Adjunct
- Publisher
- ACM
- Published
- 2016-09-12
- Pages
- 1185-1193
- OpenAlex
- W2520289546
- Cited by
- 230
- References
- 9
- FWCI
- 13.55
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.