Inertial and magnetic posture tracking for inserting humans into networked virtual environments
The DOI matches its Crossref record.
Abstract
Rigid body orientation can be determined without the aid of a generated source using nine-axis MARG (Magnetic field, Angular Rate, and Gravity) sensor unit containing three orthogonally mounted angular rate sensors, three orthogonal linear accelerometers and three orthogonal magnetometers. This paper describes a quaternion-based complementary filter algorithm for processing the output data from such a sensor. The filter forms the basis for a system designed to determine the posture of an articulated body in real-time. In the system the orientation relative to an Earth-fixed reference frame of each limb segment is individually determined through the use of an attached MARG sensor. The orientations are used to set the posture of an articulated body model. Details of the fabrication of a prototype MARG sensor are presented. Calibration algorithms for the sensors and the human body model are also presented. Experimental results demonstrate the effectiveness of the tracking system and verify the correctness of the underlying theory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Estimation of IMU and MARG orientation using a gradient descent algorithm
Madgwick, S. O. H., Harrison, A. J. L., & Vaidyanathan, R. (2011) · 2011 IEEE International Conference on Rehabilitation Robotics · doi:10.1109/icorr.2011.5975346 · Cited by 2,068
Yun, X., & Bachmann, E. R. (2006) · IEEE Transactions on Robotics · doi:10.1109/tro.2006.886270 · Cited by 569
Self-citationKeeping a Good Attitude: A Quaternion-Based Orientation Filter for IMUs and MARGs
Valenti, R., Dryanovski, I., & Xiao, J. (2015) · Sensors · doi:10.3390/s150819302 · Cited by 357
Teleoperation of a robot manipulator using a vision-based human-robot interface
Kofman, J., Wu, X., Luu, T. J., & Verma, S. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.855696 · Cited by 349
Xiaoping, Y., Bachmann, E. R., & McGhee, R. B. (2008) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2007.911646 · Cited by 320
Self-citationAmbulatory measurement of shoulder and elbow kinematics through inertial and magnetic sensors
Cutti, A. G., Giovanardi, A., Rocchi, L., Davalli, A., & Sacchetti, R. (2008) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-007-0296-5 · Cited by 311
“The data supplied by the accelerometer, gyroscope, and magnetometer are combined through sensor-fusion algorithms [2, 21, 22] to measure the 3D orientation of the SU’s system of reference (SoR)—defined based on the sensing axes of the inertial and magnetic sensors—with respect to a global, earthbased SoR.”
BackgroundMethodShoulder and Elbow Joint Angle Tracking With Inertial Sensors
El-Gohary, M., & McNames, J. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2208750 · Cited by 264
Use of multiple wearable inertial sensors in upper limb motion tracking
Zhou, H., Stone, T., Hu, H., & Harris, N. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.11.010 · Cited by 231
“To relate the movements of the sensor to those of the segments, a sensor calibration needs to be conducted [17].”
BackgroundTransPose: real-time 3D human translation and pose estimation with six inertial sensors
Yi, X., Zhou, Y., & Xu, F. (2021) · ACM Transactions on Graphics · doi:10.1145/3450626.3459786 · Cited by 202
Human Joint Angle Estimation with Inertial Sensors and Validation with A Robot Arm
El-Gohary, M., & McNames, J. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2403368 · Cited by 167
“In other studies, systems with accelerometers, gyroscopes, and magnetometers were used to measure the orientation of different body segments [20]–[24].”
MethodPosition-sensing technologies for movement analysis in stroke rehabilitation
Zheng, H., Black, N. D., & Harris, N. D. (2005) · Medical & Biological Engineering & Computing · doi:10.1007/bf02344720 · Cited by 165
Bouvier, B., Duprey, S., Claudon, L., Dumas, R., & Savescu, A. (2015) · Sensors · doi:10.3390/s150818813 · Cited by 133
“The concept underlying the functioning of the MIMU is the combination of these three types of information (accelerometers, gyroscopes, magnetometers) through sensor-fusion algorithms [20,22] to estimate a drift-free 3D orientation of the MIMU sensor.”
BackgroundInertial measurements of upper limb motion
Zhou, H., Hu, H., & Tao, Y. (2006) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-006-0063-z · Cited by 106
“[1]) may lead to over- or under-estimate of the arm position.”
Background
Metadata
- Authors
- Bachmann, E. R., McGhee, R. B., Yun, X., & Zyda, M. J.
- Venue
- Proceedings of the ACM symposium on Virtual reality software and technology
- Publisher
- ACM
- Published
- 2001-11-15
- Pages
- 9-16
- OpenAlex
- W2064313486
- Cited by
- 128
- References
- 0
- FWCI
- 7.52
- Type
- conference paper
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.