Analysis of Exhaled Breath for Disease Detection
The DOI matches its Crossref record; 225 of the 225 references it cites were found in a registry or an index.
Abstract
Breath analysis is a young field of research with great clinical potential. As a result of this interest, researchers have developed new analytical techniques that permit real-time analysis of exhaled breath with breath-to-breath resolution in addition to the conventional central laboratory methods using gas chromatography–mass spectrometry. Breath tests are based on endogenously produced volatiles, metabolites of ingested precursors, metabolites produced by bacteria in the gut or the airways, or volatiles appearing after environmental exposure. The composition of exhaled breath may contain valuable information for patients presenting with asthma, renal and liver diseases, lung cancer, chronic obstructive pulmonary disease, inflammatory lung disease, or metabolic disorders. In addition, oxidative stress status may be monitored via volatile products of lipid peroxidation. Measurement of enzyme activity provides phenotypic information important in personalized medicine, whereas breath measurements provide insight into perturbations of the human exposome and can be interpreted as preclinical signals of adverse outcome pathways.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(1992) · Applied Ergonomics · doi:10.1016/0003-6870(92)90338-v · Cited by 7,112
J Heart Lung Transplant 2021;40(4).
(2021) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2021.04.002 · Cited by 6,665
(2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200406-710st · Cited by 3,203
Puzzlingly High Correlations in fMRI Studies of Emotion, Personality, and Social Cognition
Vul, E., Harris, C., Winkielman, P., & Pashler, H. (2009) · Perspectives on Psychological Science · doi:10.1111/j.1745-6924.2009.01125.x · Cited by 1,475
Diagnosing lung cancer in exhaled breath using gold nanoparticles
Peng, G., Tisch, U., Adams, O., Hakim, M., Shehada, N., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., & Haick, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.235 · Cited by 1,263
Increased amount of nitric oxide in exhaled air of asthmatics
Alving, K., Weitzberg, E., & Lundberg, J. (1993) · European Respiratory Journal · doi:10.1183/09031936.93.06091368 · Cited by 1,232
Diagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
Self-citationA review of the volatiles from the healthy human body
de Lacy Costello, B., Amann, A., Al-Kateb, H., Flynn, C., Filipiak, W., Khalid, T., Osborne, D., & Ratcliffe, N. M. (2014) · Journal of Breath Research · doi:10.1088/1752-7155/8/1/014001 · Cited by 1,042
Self-citationMeasurement of F2-isoprostanes as an index of oxidative stress in vivo
Roberts, L. J., & Morrow, J. D. (2000) · Free Radical Biology and Medicine · doi:10.1016/s0891-5849(99)00264-6 · Cited by 996
Volatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways
Hakim, M., Broza, Y. Y., Barash, O., Peled, N., Phillips, M., Amann, A., & Haick, H. (2012) · Chemical Reviews · doi:10.1021/cr300174a · Cited by 953
Self-citation
Cited by
Sensors for Volatile Organic Compounds
Khatib, M., & Haick, H. (2022) · ACS Nano · doi:10.1021/acsnano.1c10827 · Cited by 533
Potyrailo, R. A. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00187 · Cited by 460
Metabolomics for laboratory diagnostics
Bujak, R., Struck-Lewicka, W., Markuszewski, M. J., & Kaliszan, R. (2015) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2014.12.017 · Cited by 430
Wearable and Miniaturized Sensor Technologies for Personalized and Preventive Medicine
Tricoli, A., Nasiri, N., & De, S. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201605271 · Cited by 346
Breath Analysis as a Potential and Non-Invasive Frontier in Disease Diagnosis: An Overview
Pereira, J., Porto-Figueira, P., Cavaco, C., Taunk, K., Rapole, S., Dhakne, R., Nagarajaram, H., & Câmara, J. (2015) · Metabolites · doi:10.3390/metabo5010003 · Cited by 301
Volatile Organic Compound Emissions from Humans Indoors
Tang, X., Misztal, P. K., Nazaroff, W. W., & Goldstein, A. H. (2016) · Environmental Science & Technology · doi:10.1021/acs.est.6b04415 · Cited by 295
Hybrid Volatolomics and Disease Detection
Broza, Y. Y., Mochalski, P., Ruzsanyi, V., Amann, A., & Haick, H. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201500153 · Cited by 290
Self-citationPeng, B., Zhao, F., Ping, J., & Ying, Y. (2020) · Small · doi:10.1002/smll.202002681 · Cited by 224
Laser spectroscopy for breath analysis: towards clinical implementation
Henderson, B., Khodabakhsh, A., Metsälä, M., Ventrillard, I., Schmidt, F. M., Romanini, D., Ritchie, G. A. D., te Lintel Hekkert, S., Briot, R., Risby, T., et al. (2018) · Applied Physics B · doi:10.1007/s00340-018-7030-x · Cited by 224
Self-citationQuantum cascade lasers (QCLs) in biomedical spectroscopy
Schwaighofer, A., Brandstetter, M., & Lendl, B. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00403f · Cited by 199
Nanoscale Sensor Technologies for Disease Detection via Volatolomics
Vishinkin, R., & Haick, H. (2015) · Small · doi:10.1002/smll.201501904 · Cited by 199
Vincent, T. A., & Gardner, J. W. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2016.04.016 · Cited by 171
Exhaled Molecular Fingerprinting in Diagnosis and Monitoring: Validating Volatile Promises
Boots, A. W., Bos, L. D., van der Schee, M. P., van Schooten, F.-J., & Sterk, P. J. (2015) · Trends in Molecular Medicine · doi:10.1016/j.molmed.2015.08.001 · Cited by 167
“Interestingly, for some of these conditions it has also been shown that altered volatiles are present in other body fluids, including urine and feces and/or their headspaces [55].”
BackgroundDas, S., Pal, S., & Mitra, M. (2016) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-016-0164-6 · Cited by 164
Breath VOC analysis and machine learning approaches for disease screening: a review
P, H., Rangarajan, M., & Pandya, H. J. (2023) · Journal of Breath Research · doi:10.1088/1752-7163/acb283 · Cited by 37
“Thus, exhaled breath analysis is commonly used for detecting particular diseases [7].”
Electrical sensing of volatile organic compounds in exhaled breath for disease diagnosis
Yan, H., & Zhou, Y.-G. (2022) · Current Opinion in Electrochemistry · doi:10.1016/j.coelec.2021.100922 · Cited by 29
Metadata
- Authors
- Amann, A., Miekisch, W., Schubert, J., Buszewski, B., Ligor, T., Jezierski, T., Pleil, J., & Risby, T.
- Venue
- Annual Review of Analytical Chemistry
- Publisher
- Annual Reviews
- Published
- 2014-06-12
- Volume
- 7
- Issue
- 1
- Pages
- 455-482
- ISSN
- 1936-1327 (ISSN-L)
- 1936-1335
- OpenAlex
- W2120695740
- Cited by
- 214
- References
- 225
- FWCI
- 1.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.