Bioengineering Challenges for Heart Valve Tissue Engineering
The DOI matches its Crossref record; 94 of the 94 references it cites were found in a registry or an index.
Abstract
Surgical replacement of diseased heart valves by mechanical and tissue valve substitutes is now commonplace and enhances survival and quality of life for many patients. However, repairs of congenital deformities require very small valve sizes not commercially available. Further, a fundamental problem inherent to the use of existing mechanical and biological prostheses in the pediatric population is their failure to grow, repair, and remodel. It is believed that a tissue engineered heart valve can accommodate many of these requirements, especially those pertaining to somatic growth. This review provides an overview of the field of heart valve tissue engineering, including recent trends, with a focus on the bioengineering challenges unique to heart valves. We believe that, currently, the key bioengineering challenge is to determine how biological, structural, and mechanical factors affect extracellular matrix (ECM) formation and in vivo functionality. These factors are fundamental to any approach toward developing a clinically viable tissue engineered heart valve (TEHV), regardless of the particular approach. Critical to the current approaches to TEHVs is scaffold design, which must simultaneously provide function (valves must function from the time of implant) as well as stress transfer to the new ECM. From a bioengineering point of view, a hierarchy of approaches will be necessary to connect the organ-tissue relationships with underpinning cell and sub-cellular events. Overall, such approaches need to be structured to address these fundamental issues to lay the basis for TEHVs that can be developed and designed according to truly sound scientific and engineering principles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new constitutive framework for arterial wall mechanics and a comparative study of material models
Holzapfel, G. A., Gasser, T. C., & Ogden, R. W. (2000) · Journal of Elasticity · doi:10.1023/a:1010835316564 · Cited by 3,071
Electrospinning of Polymeric Nanofibers for Tissue Engineering Applications: A Review
Pham, Q. P., Sharma, U., & Mikos, A. G. (2006) · Tissue Engineering · doi:10.1089/ten.2006.12.1197 · Cited by 2,256
A biodegradable nanofiber scaffold by electrospinning and its potential for bone tissue engineering
Yoshimoto, H., Shin, Y. M., Terai, H., & Vacanti, J. P. (2003) · Biomaterials · doi:10.1016/s0142-9612(02)00635-x · Cited by 1,977
Functional Arteries Grown in Vitro
Niklason, L. E., Gao, J., Abbott, W. M., Hirschi, K. K., Houser, S., Marini, R., & Langer, R. (1999) · Science · doi:10.1126/science.284.5413.489 · Cited by 1,766
Biodegradable Polymer Scaffolds for Tissue Engineering
Freed, L. E., Vunjak-Novakovic, G., Biron, R. J., Eagles, D. B., Lesnoy, D. C., Barlow, S. K., & Langer, R. (1994) · Nature Biotechnology · doi:10.1038/nbt0794-689 · Cited by 1,235
Thromboembolic and bleeding complications in patients with mechanical heart valve prostheses.
Cannegieter, S. C., Rosendaal, F. R., & Briët, E. (1994) · Circulation · doi:10.1161/01.cir.89.2.635 · Cited by 1,068
Constitutive equations for fibrous connective tissues
Lanir, Y. (1983) · Journal of Biomechanics · doi:10.1016/0021-9290(83)90041-6 · Cited by 741
Guan, J., Fujimoto, K. L., Sacks, M. S., & Wagner, W. R. (2005) · Biomaterials · doi:10.1016/j.biomaterials.2004.10.018 · Cited by 703
Self-citationPseudoelasticity of arteries and the choice of its mathematical expression
Fung, Y. C., Fronek, K., & Patitucci, P. (1979) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1979.237.5.h620 · Cited by 688
Functional Tissue Engineering: The Role of Biomechanics
Butler, D. L., Goldstein, S. A., & Guilak, F. (2000) · Journal of Biomechanical Engineering · doi:10.1115/1.1318906 · Cited by 624
Cited by
3D Bioprinting of heterogeneous aortic valve conduits with alginate/gelatin hydrogels
Duan, B., Hockaday, L. A., Kang, K. H., & Butcher, J. T. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34420 · Cited by 1,002
Tissue Engineering and Regenerative Medicine: History, Progress, and Challenges
Berthiaume, F., Maguire, T. J., & Yarmush, M. L. (2011) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-061010-114257 · Cited by 734
Hockaday, L. A., Kang, K. H., Colangelo, N. W., Cheung, P. Y. C., Duan, B., Malone, E., Wu, J., Girardi, L. N., Bonassar, L. J., Lipson, H., et al. (2012) · Biofabrication · doi:10.1088/1758-5082/4/3/035005 · Cited by 683
Synthesis, properties and biomedical applications of poly(glycerol sebacate) (PGS): A review
Rai, R., Tallawi, M., Grigore, A., & Boccaccini, A. R. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.02.001 · Cited by 477
Duan, B., Kapetanovic, E., Hockaday, L. A., & Butcher, J. T. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2013.12.005 · Cited by 436
Chen, F.-M., Wu, L.-A., Zhang, M., Zhang, R., & Sun, H.-H. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2010.12.032 · Cited by 381
On the biomechanics of heart valve function
Sacks, M. S., David Merryman, W., & Schmidt, D. E. (2009) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.05.015 · Cited by 372
Self-citationSubstrates for cardiovascular tissue engineering
Bouten, C. V. C., Dankers, P. Y. W., Driessen-Mol, A., Pedron, S., Brizard, A. M. A., & Baaijens, F. P. T. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.01.007 · Cited by 261
Aortic valve disease and treatment: The need for naturally engineered solutions
Butcher, J. T., Mahler, G. J., & Hockaday, L. A. (2011) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2011.01.008 · Cited by 210
“The cusps need to be sufficiently compliant so as to not impede blood ejection (risking stenosis) while the root wall needs to be sufficiently stiff to not pathologically dilate (risking aneurysm) [400].”
BackgroundInfluentialBiomaterial applications in cardiovascular tissue repair and regeneration
Lam, M. T., & Wu, J. C. (2012) · Expert Review of Cardiovascular Therapy · doi:10.1586/erc.12.99 · Cited by 203
Collagen and Elastin Biomaterials for the Fabrication of Engineered Living Tissues
Miranda-Nieves, D., & Chaikof, E. L. (2017) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.6b00250 · Cited by 175
Scaffolds for tissue engineering of cardiac valves
Jana, S., Tefft, B. J., Spoon, D. B., & Simari, R. D. (2014) · Acta Biomaterialia · doi:10.1016/j.actbio.2014.03.014 · Cited by 169
“proliferate and differentiate into specific cell types [206-208].”
BackgroundHybrid PGS-PCL microfibrous scaffolds with improved mechanical and biological properties
Sant, S., Hwang, C. M., Lee, S.-H., & Khademhosseini, A. (2011) · Journal of Tissue Engineering and Regenerative Medicine · doi:10.1002/term.313 · Cited by 162
“Such fibrous structures are favourable for handling tensile loads while maintaining relatively low bending rigidities (Mauck et al., 2009; Sacks et al., 2009).”
Current progress in tissue engineering of heart valves: multiscale problems, multiscale solutions
Cheung, D. Y., Duan, B., & Butcher, J. T. (2015) · Expert Opinion on Biological Therapy · doi:10.1517/14712598.2015.1051527 · Cited by 160
“The engineered valves must be non-thrombogenic, non-obstructive, and able to open and close promptly and completely [40].”
BackgroundJetValve: Rapid manufacturing of biohybrid scaffolds for biomimetic heart valve replacement
Capulli, A. K., Emmert, M. Y., Pasqualini, F. S., Kehl, D., Caliskan, E., Lind, J. U., Sheehy, S. P., Park, S. J., Ahn, S., Weber, B., et al. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.04.033 · Cited by 112
Metadata
- Authors
- Sacks, M. S., Schoen, F. J., & Mayer, J. E.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2009-08-01
- Volume
- 11
- Issue
- 1
- Pages
- 289-313
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2105624703
- Cited by
- 256
- References
- 94
- FWCI
- 4.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.