The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Superresolution Multidimensional Imaging with Structured Illumination Microscopy
Abstract
The resolution of an optical microscope is fundamentally limited by diffraction. In a conventional wide-field fluorescence microscope, the resolution limit is at best 200 nm. However, modern superresolution methods can bypass this limit. Pointillistic imaging techniques like PALM (photoactivated localization microscopy) and STORM (stochastic optical reconstruction microscopy) do so by precisely localizing each individual molecule in a sample. In contrast, STED uses the stimulated emission process driven to saturation to dramatically reduce the size of the region in the sample that is capable of spontaneously emitting fluorescence. Structured illumination microscopy (SIM) illuminates the sample with a pattern, typically the image of a grating. This computationally removes the out-of-focus blur, a method known as optical sectioning SIM. Furthermore, frequency mixing of the illumination pattern with the sample caused by the moiré effect results in a downmodulation of fine sample detail into the frequency-support region of the detection optical transfer function. High-resolution SIM achieves typically a twofold lateral resolution enhancement. This is further improved by exploiting a nonlinear sample response to the illumination light in SIM. Recent developments of the method allow fast, multicolor, and three-dimensional high-resolution live-cell imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Green fluorescent protein as a marker for gene expression
Chalfie, M., Tu, Y., Euskirchen, G., Ward, W. W., & Prasher, D. C. (1994) · Science · doi:10.1126/science.8303295 · Cited by 6,802
Hell, S. W., & Wichmann, J. (1994) · Optics Letters · doi:10.1364/ol.19.000780 · Cited by 6,065
Gustafsson, M. G. L. (2000) · Journal of Microscopy · doi:10.1046/j.1365-2818.2000.00710.x · Cited by 3,786
Gustafsson, M. G. L., Shao, L., Carlton, P. M., Wang, C. J. R., Golubovskaya, I. N., Cande, W. Z., Agard, D. A., & Sedat, J. W. (2008) · Biophysical Journal · doi:10.1529/biophysj.107.120345 · Cited by 1,557
A guide to super-resolution fluorescence microscopy
Schermelleh, L., Heintzmann, R., & Leonhardt, H. (2010) · Journal of Cell Biology · doi:10.1083/jcb.201002018 · Cited by 1,255
Self-citationMethod of obtaining optical sectioning by using structured light in a conventional microscope
Neil, M. A. A., Juškaitis, R., & Wilson, T. (1997) · Optics Letters · doi:10.1364/ol.22.001905 · Cited by 1,143
Schermelleh, L., Carlton, P. M., Haase, S., Shao, L., Winoto, L., Kner, P., Burke, B., Cardoso, M. C., Agard, D. A., Gustafsson, M. G. L., et al. (2008) · Science · doi:10.1126/science.1156947 · Cited by 1,123
Cited by
Pandey, R., Vats, G., Yun, J., Bowen, C. R., Ho‐Baillie, A. W. Y., Seidel, J., Butler, K. T., & Seok, S. I. (2019) · Advanced Materials · doi:10.1002/adma.201807376 · Cited by 1,069
Rare-earth nickelates R NiO 3 : thin films and heterostructures
Catalano, S., Gibert, M., Fowlie, J., Íñiguez, J., Triscone, J.-M., & Kreisel, J. (2018) · Reports on Progress in Physics · doi:10.1088/1361-6633/aaa37a · Cited by 453
Tesler, A. B., Kim, P., Kolle, S., Howell, C., Ahanotu, O., & Aizenberg, J. (2015) · Nature Communications · doi:10.1038/ncomms9649 · Cited by 418
Crystallization in Confinement
Meldrum, F. C., & O'Shaughnessy, C. (2020) · Advanced Materials · doi:10.1002/adma.202001068 · Cited by 338
Nonequilibrium Thermodynamics of Porous Electrodes
Ferguson, T. R., & Bazant, M. Z. (2012) · Journal of The Electrochemical Society · doi:10.1149/2.048212jes · Cited by 333
Metadata
- Authors
- Jost, A., & Heintzmann, R.
- Venue
- Annual Review of Materials Research
- Publisher
- Annual Reviews
- Published
- 2013-07-01
- Volume
- 43
- Issue
- 1
- Pages
- 261-282
- ISSN
- 1531-7331 (ISSN-L)
- 1545-4118
- OpenAlex
- W2141564450
- Cited by
- 318
- References
- 30
- FWCI
- 3.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Superresolution Multidimensional Imaging with Structured Illumination Microscopy. https://app.cochat.ai/papers/10.1146/annurev-matsci-071312-121648
- The paper
- Jost, A., & Heintzmann, R. (2013). Superresolution Multidimensional Imaging with Structured Illumination Microscopy. Annual Review of Materials Research. https://doi.org/10.1146/annurev-matsci-071312-121648
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.