Fluorescence Proteins, Live-Cell Imaging, and Mechanobiology: Seeing Is Believing
The DOI matches its Crossref record; 230 of the 230 references it cites were found in a registry or an index.
Abstract
Fluorescence proteins (FPs) have been widely used for live-cell imaging in the past decade. This review summarizes the recent advances in FP development and imaging technologies using FPs to monitor molecular localization and activities and gene expressions in live cells. We also discuss the utilization of FPs to develop molecular biosensors and the principles and application of advanced technologies such as fluorescence resonance energy transfer (FRET), fluorescence recovery after photobleaching (FRAP), fluorescence lifetime imaging microscopy (FLIM), and chromophore-assisted light inactivation (CALI). We present examples of the application of FPs and biosensors to visualize mechanotransduction events with high spatiotemporal resolutions in live cells. These live-cell imaging technologies, which represent a frontier area in biomedical engineering, can shed new light on the mechanisms regulating mechanobiology at cellular and molecular levels in normal and pathophysiological conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Green fluorescent protein as a marker for gene expression
Chalfie, M., Tu, Y., Euskirchen, G., Ward, W. W., & Prasher, D. C. (1994) · Science · doi:10.1126/science.8303295 · Cited by 6,802
Tsien, R. Y. (1998) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.67.1.509 · Cited by 6,143
Resting microglial cells are highly dynamic surveillants of brain parenchyma in vivo
Nimmerjahn, A., Kirchhoff, F., & Helmchen, F. (2005) · Science · doi:10.1126/science.1110647 · Cited by 5,827
Shaner, N. C., Campbell, R. E., Steinbach, P. A., Giepmans, B. N. G., Palmer, A. E., & Tsien, R. Y. (2004) · Nature Biotechnology · doi:10.1038/nbt1037 · Cited by 4,619
Fluorescent indicators for Ca2+based on green fluorescent proteins and calmodulin
Miyawaki, A., Llopis, J., Heim, R., McCaffery, J. M., Adams, J. A., Ikura, M., & Tsien, R. Y. (1997) · Nature · doi:10.1038/42264 · Cited by 3,248
Taking Cell-Matrix Adhesions to the Third Dimension
Cukierman, E., Pankov, R., Stevens, D. R., & Yamada, K. M. (2001) · Science · doi:10.1126/science.1064829 · Cited by 3,027
A guide to choosing fluorescent proteins
Shaner, N. C., Steinbach, P. A., & Tsien, R. Y. (2005) · Nature Methods · doi:10.1038/nmeth819 · Cited by 2,840
The Fluorescent Toolbox for Assessing Protein Location and Function
Giepmans, B. N. G., Adams, S. R., Ellisman, M. H., & Tsien, R. Y. (2006) · Science · doi:10.1126/science.1124618 · Cited by 2,770
Nagai, T., Ibata, K., Park, E. S., Kubota, M., Mikoshiba, K., & Miyawaki, A. (2002) · Nature Biotechnology · doi:10.1038/nbt0102-87 · Cited by 2,753
Cited by
Aggregation‐Induced Emission: The Whole Is More Brilliant than the Parts
Mei, J., Hong, Y., Lam, J. W. Y., Qin, A., Tang, Y., & Tang, B. Z. (2014) · Advanced Materials · doi:10.1002/adma.201401356 · Cited by 3,381
Fluorescence Lifetime Measurements and Biological Imaging
Berezin, M. Y., & Achilefu, S. (2010) · Chemical Reviews · doi:10.1021/cr900343z · Cited by 2,403
Imaging and Photodynamic Therapy: Mechanisms, Monitoring, and Optimization
Celli, J. P., Spring, B. Q., Rizvi, I., Evans, C. L., Samkoe, K. S., Verma, S., Pogue, B. W., & Hasan, T. (2010) · Chemical Reviews · doi:10.1021/cr900300p · Cited by 2,324
Relative and absolute determination of fluorescence quantum yields of transparent samples
Würth, C., Grabolle, M., Pauli, J., Spieles, M., & Resch-Genger, U. (2013) · Nature Protocols · doi:10.1038/nprot.2013.087 · Cited by 1,216
Long-Lived Emissive Probes for Time-Resolved Photoluminescence Bioimaging and Biosensing
Zhang, K. Y., Yu, Q., Wei, H., Liu, S., Zhao, Q., & Huang, W. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00425 · Cited by 923
Molecular Imaging by Means of Multispectral Optoacoustic Tomography (MSOT)
Ntziachristos, V., & Razansky, D. (2010) · Chemical Reviews · doi:10.1021/cr9002566 · Cited by 776
Fluorescent probes for sensing and imaging
Ueno, T., & Nagano, T. (2011) · Nature Methods · doi:10.1038/nmeth.1663 · Cited by 633
A review of progress in single particle tracking: from methods to biophysical insights
Manzo, C., & Garcia-Parajo, M. F. (2015) · Reports on Progress in Physics · doi:10.1088/0034-4885/78/12/124601 · Cited by 597
Probing Liquid/Solid Interfaces at the Molecular Level
Zaera, F. (2012) · Chemical Reviews · doi:10.1021/cr2002068 · Cited by 458
Microengineered Platforms for Cell Mechanobiology
Kim, D.-H., Wong, P. K., Park, J., Levchenko, A., & Sun, Y. (2009) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-061008-124915 · Cited by 411
Förster resonance energy transfer – A spectroscopic nanoruler: Principle and applications
Sahoo, H. (2011) · Journal of Photochemistry and Photobiology C: Photochemistry Reviews · doi:10.1016/j.jphotochemrev.2011.05.001 · Cited by 405
Recent Advances in Magnetic Tweezers
De Vlaminck, I., & Dekker, C. (2012) · Annual Review of Biophysics · doi:10.1146/annurev-biophys-122311-100544 · Cited by 374
Fluorescent proteins for live-cell imaging with super-resolution
Nienhaus, K., & Ulrich Nienhaus, G. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60171d · Cited by 337
Live-cell microscopy – tips and tools
Frigault, M. M., Lacoste, J., Swift, J. L., & Brown, C. M. (2009) · Journal of Cell Science · doi:10.1242/jcs.033837 · Cited by 304
Polymer-Coated NaYF4:Yb3+, Er3+ Upconversion Nanoparticles for Charge-Dependent Cellular Imaging
Jin, J., Gu, Y.-J., Man, C. W.-Y., Cheng, J., Xu, Z., Zhang, Y., Wang, H., Lee, V. H.-Y., Cheng, S. H., & Wong, W.-T. (2011) · ACS Nano · doi:10.1021/nn201896m · Cited by 290
Chowdhury, D. (2013) · Physics Reports · doi:10.1016/j.physrep.2013.03.005 · Cited by 212
Ouyang, M., Sun, J., Chien, S., & Wang, Y. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0807537105 · Cited by 189
“Hence, these biosensors have been widely developed and applied for the detection of various molecular activities in live cells with high spatiotemporal resolution (2).”
BackgroundSelf-citationThe nano-architecture of the axonal cytoskeleton
Leterrier, C., Dubey, P., & Roy, S. (2017) · Nature Reviews Neuroscience · doi:10.1038/nrn.2017.129 · Cited by 166
Quantitative Time-Lapse Fluorescence Microscopy in Single Cells
Muzzey, D., & van Oudenaarden, A. (2009) · Annual Review of Cell and Developmental Biology · doi:10.1146/annurev.cellbio.042308.113408 · Cited by 160
“The refinement and development of new fluorophore technologies have been rampant in recent years (Wang et al. 2008), and we expect progress to persist.”
BackgroundProtein Homeostasis and Aging: Taking Care of Proteins From the Cradle to the Grave
Morimoto, R. I., & Cuervo, A. M. (2009) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/gln071 · Cited by 151
Advances in cell‐based biosensors using three‐dimensional cell‐encapsulating hydrogels
Zhou, L., Huang, G., Wang, S., Wu, J., Lee, W. G., Chen, Y., Xu, F., & Lu, T. (2011) · Biotechnology Journal · doi:10.1002/biot.201100098 · Cited by 17
Metadata
- Authors
- Wang, Y., Shyy, J. Y.-J., & Chien, S.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2008-08-01
- Volume
- 10
- Issue
- 1
- Pages
- 1-38
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2126629698
- Cited by
- 310
- References
- 230
- FWCI
- 1.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.