New Currents in Electrical Stimulation of Excitable Tissues
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
▪ Abstract Electric fields can stimulate excitable tissue by a number of mechanisms. A uniform long, straight peripheral axon is activated by the gradient of the electric field that is oriented parallel to the fiber axis. Cortical neurons in the brain are excited when the electric field, which is applied along the axon-dendrite axis, reaches a particular threshold value. Cardiac tissue is thought to be depolarized in a uniform electric field by the curved trajectories of its fiber tracts. The bidomain model provides a coherent conceptual framework for analyzing and understanding these apparently disparate phenomena. Concepts such as the activating function and virtual anode and cathode, as well as anode and cathode break and make stimulation, are presented to help explain these excitation events in a unified manner. This modeling approach can also be used to describe the response of excitable tissues to electric fields that arise from charge redistribution (electrical stimulation) and from time-varying magnetic fields (magnetic stimulation) in a self-consistent manner. It has also proved useful to predict the behavior of excitable tissues, to test hypotheses about possible excitation mechanisms, to design novel electrophysiological experiments, and to interpret their findings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Which elements are excited in electrical stimulation of mammalian central nervous system: A review
Ranck, J. B. (1975) · Brain Research · doi:10.1016/0006-8993(75)90364-9 · Cited by 2,024
Analysis of a Model for Excitation of Myelinated Nerve
McNeal, D. R. (1976) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1976.324593 · Cited by 833
Analysis of Models for External Stimulation of Axons
Rattay, F. (1986) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1986.325670 · Cited by 681 · cited 1×
“a Ve/ax , where Ve is the extracellular potential (8, 34).”
BackgroundSelective activation of small motor axons by quasitrapezoidal current pulses
Fang, Z.-P., & Mortimer, J. T. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76383 · Cited by 222 · cited 2×
“Therefore, action potentials propagate far from the electrode only in the small fibers (13, 18-20).”
BackgroundRattay, F. (1990) · doi:10.1007/978-3-7091-3271-5 · Cited by 190
A method to effect physiological recruitment order in electrically activated muscle
Fang, Z.-P., & Mortimer, J. T. (1991) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.76384 · Cited by 125 · cited 2×
“The develop ment of such undirectional block techniques has been useful in functional electrical stimulation (15-19).”
BackgroundMethodInversion of the current-distance relationship by transient depolarization
Grill, W. M., & Mortimer, J. T. (1997) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.553708 · Cited by 109
Cited by
Neural Stimulation and Recording Electrodes
Cogan, S. F. (2008) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.10.061807.160518 · Cited by 2,243
Cellular effects of acute direct current stimulation: somatic and synaptic terminal effects
Rahman, A., Reato, D., Arlotti, M., Gasca, F., Datta, A., Parra, L. C., & Bikson, M. (2013) · The Journal of Physiology · doi:10.1113/jphysiol.2012.247171 · Cited by 560
McIntyre, C. C., Mori, S., Sherman, D. L., Thakor, N. V., & Vitek, J. L. (2004) · Clinical Neurophysiology · doi:10.1016/j.clinph.2003.10.033 · Cited by 492
Peterchev, A. V., Wagner, T. A., Miranda, P. C., Nitsche, M. A., Paulus, W., Lisanby, S. H., Pascual-Leone, A., & Bikson, M. (2012) · Brain Stimulation · doi:10.1016/j.brs.2011.10.001 · Cited by 429
Pell, G. S., Roth, Y., & Zangen, A. (2011) · Progress in Neurobiology · doi:10.1016/j.pneurobio.2010.10.003 · Cited by 406
McIntyre, C. C., & Grill, W. M. (2002) · Journal of Neurophysiology · doi:10.1152/jn.2002.88.4.1592 · Cited by 384
Gross, R. E., Krack, P., Rodriguez-Oroz, M. C., Rezai, A. R., & Benabid, A.-L. (2006) · Movement Disorders · doi:10.1002/mds.20960 · Cited by 324
Bédard, C., Kröger, H., & Destexhe, A. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74250-2 · Cited by 264
Rauti, R., Musto, M., Bosi, S., Prato, M., & Ballerini, L. (2019) · Carbon · doi:10.1016/j.carbon.2018.11.026 · Cited by 216
“A reverse process takes place during stimulation where charges are delivered from the electrode to affect membrane potential [37 e 39].”
Electroactive Smart Polymers for Biomedical Applications
Palza, H., Zapata, P. A., & Angulo-Pineda, C. (2019) · Materials · doi:10.3390/ma12020277 · Cited by 196
“The effect of an electrical field is not only valid for cells but also for tissues [71].”
BackgroundPrinciples of electrical stimulation of neural tissue
(2013) · Handbook of Clinical Neurology · doi:10.1016/b978-0-444-53497-2.00001-2 · Cited by 151
Tahayori, B., Meffin, H., Sergeev, E. N., Mareels, I. M. Y., Burkitt, A. N., & Grayden, D. B. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/6/065005 · Cited by 24
High-frequency electrical stimulation of cardiac cells and application to artifact reduction.
Dura, B., Chen, M. Q., Inan, O. T., Kovacs, G. T. A., & Giovangrandi, L. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2188136 · Cited by 15
Metadata
- Authors
- Basser, P. J., & Roth, B. J.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2000-08
- Volume
- 2
- Issue
- 1
- Pages
- 377-397
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2148197712
- Cited by
- 148
- References
- 7
- FWCI
- 0.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.