MULTIMODALITY IN VIVO IMAGING SYSTEMS: Twice the Power or Double the Trouble?
The DOI matches its Crossref record; 76 of the 76 references it cites were found in a registry or an index.
Abstract
Many different types of radiation have been exploited to provide images of the structure and function of tissues inside a living subject. Each imaging modality is characterized by differing resolutions on the spatial and temporal scales, and by a different sensitivity for measuring properties related to morphology or function. Combinations of imaging modalities that integrate the strengths of two modalities, and at the same time eliminate one or more weaknesses of an individual modality, thus offer the prospect of improved diagnostics, therapeutic monitoring, and preclinical research using imaging approaches. This review discusses the advantages and challenges in developing multimodality imaging systems for in vivo use, highlights some successful combinations that are now routinely used in the clinic and in research, and discusses recent advances in multimodality instrumentation that may offer new opportunities for imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical tomography in medical imaging
Arridge, S. R. (1999) · Inverse Problems · doi:10.1088/0266-5611/15/2/022 · Cited by 2,524 · cited 1×
“raphy, is also being pursued for clinical applications, especially for breast imaging and neonatal brain imaging (94).”
Molecular imaging in living subjects: seeing fundamental biological processes in a new light
Massoud, T. F., & Gambhir, S. S. (2003) · Genes & Development · doi:10.1101/gad.1047403 · Cited by 2,216
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
The Essential Physics of Medical Imaging
Bushberg, J. T., Seibert, J. A., Leidholdt, E. M., Boone, J. M., & Goldschmidt, E. J. (2003) · Medical Physics · doi:10.1118/1.1585033 · Cited by 1,987
Wang, X., Pang, Y., Ku, G., Xie, X., Stoica, G., & Wang, L. V. (2003) · Nature Biotechnology · doi:10.1038/nbt839 · Cited by 1,700 · cited 1×
“Both structural and functional in vivo imaging have been accomplished with this technique (100).”
A combined PET/CT scanner for clinical oncology.
Beyer, T., Townsend, D. W., Brun, T., Kinahan, P. E., Charron, M., Roddy, R., Jerin, J., Young, J., Byars, L. G., & Nutt, R. (2000) · PubMed · Cited by 1,659
Quantitation in Positron Emission Computed Tomography: 1. Effect of Object Size
Hoffman, E. J., Huang, S.-C., & Phelps, M. E. (1979) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197906000-00001 · Cited by 1,143
Ntziachristos, V., Bremer, C., & Weissleder, R. (2003) · European Radiology · doi:10.1007/s00330-002-1524-x · Cited by 982 · cited 1×
“Several groups have been making excellent progress toward quantitative 3-D optical (89) fluorescence (90, 91) and bioluminescence tomography (92, 93).”
Attenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946 · cited 1×
“Approaches to map from CT-derived energy-averaged μ values to values appropriate for attenuation correction of PET or SPECT data arising from monoenergetic photons have therefore been developed (30, 31).”
Advances in In Vivo Bioluminescence Imaging of Gene Expression
Contag, C. H., & Bachmann, M. H. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.111901.093336 · Cited by 870 · cited 1×
“Optical imaging is the most widely utilized modality for preclinical molecular imaging, due in large part to easy accessibility of fluorescent probes and bioluminescent and fluorescent reporter proteins (87, 88).”
Cited by
Nanoprobes with near-infrared persistent luminescence for in vivo imaging
le Masne de Chermont, Q., Chanéac, C., Seguin, J., Pellé, F., Maîtrejean, S., Jolivet, J.-P., Gourier, D., Bessodes, M., & Scherman, D. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0702427104 · Cited by 834
Molecular Imaging by Means of Multispectral Optoacoustic Tomography (MSOT)
Ntziachristos, V., & Razansky, D. (2010) · Chemical Reviews · doi:10.1021/cr9002566 · Cited by 776
Nanogels: An overview of properties, biomedical applications and obstacles to clinical translation
Soni, K. S., Desale, S. S., & Bronich, T. K. (2016) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.11.009 · Cited by 683
Nanoparticles in magnetic resonance imaging: from simple to dual contrast agents
Busquets, M. A., Estelrich, J., & Sánchez-Martín, M. J. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s76501 · Cited by 622
Hydrogels as intelligent materials: A brief review of synthesis, properties and applications
Mahinroosta, M., Jomeh Farsangi, Z., Allahverdi, A., & Shakoori, Z. (2018) · Materials Today Chemistry · doi:10.1016/j.mtchem.2018.02.004 · Cited by 551
PET/NIRF/MRI triple functional iron oxide nanoparticles
Xie, J., Chen, K., Huang, J., Lee, S., Wang, J., Gao, J., Li, X., & Chen, X. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2010.01.010 · Cited by 493
Advanced optoacoustic methods for multiscale imaging of in vivo dynamics
Deán-Ben, X. L., Gottschalk, S., Mc Larney, B., Shoham, S., & Razansky, D. (2017) · Chemical Society Reviews · doi:10.1039/c6cs00765a · Cited by 337
Chimeric Ferritin Nanocages for Multiple Function Loading and Multimodal Imaging
Lin, X., Xie, J., Niu, G., Zhang, F., Gao, H., Yang, M., Quan, Q., Aronova, M. A., Zhang, G., Lee, S., et al. (2011) · Nano Letters · doi:10.1021/nl104141g · Cited by 264
PET/MR Imaging: Technical Aspects and Potential Clinical Applications
Torigian, D. A., Zaidi, H., Kwee, T. C., Saboury, B., Udupa, J. K., Cho, Z.-H., & Alavi, A. (2013) · Radiology · doi:10.1148/radiol.13121038 · Cited by 247
Multimodality Imaging: Beyond PET/CT and SPECT/CT
Cherry, S. R. (2009) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2009.03.001 · Cited by 238
“To frame the discussion on multimodality imaging, past, present and future, it is useful to consider the different levels of integration that can be involved [16].”
BackgroundSelf-citationRadiolabeled Nanoparticles for Multimodality Tumor Imaging
Xing, Y., Zhao, J., Conti, P. S., & Chen, K. (2014) · Theranostics · doi:10.7150/thno.7341 · Cited by 234
“The idea of applying multiple modalities in a single imaging session comes from the fact that modalities with high sensitivity have relatively poor resolution, while those with high resolution have relatively poor sensitivity [83, 84].”
BackgroundAn outlook on future design of hybrid PET/MRI systems: Design of hybrid PET/MRI scanners
Zaidi, H., & Del Guerra, A. (2011) · Medical Physics · doi:10.1118/1.3633909 · Cited by 193
Pablico-Lansigan, M. H., Situ, S. F., & Samia, A. C. S. (2013) · Nanoscale · doi:10.1039/c3nr00544e · Cited by 172
The use of SPECT and PET in routine clinical practice in epilepsy
Van Paesschen, W., Dupont, P., Sunaert, S., Goffin, K., & Van Laere, K. (2007) · Current Opinion in Neurology · doi:10.1097/wco.0b013e328042baf6 · Cited by 158
The Orthanc Ecosystem for Medical Imaging
Jodogne, S. (2018) · Journal of Digital Imaging · doi:10.1007/s10278-018-0082-y · Cited by 93
“By combining information arising from different imaging modalities (CT, PET, MRI, US. . . ), patients benefit from extremely personalized, high-quality treatments [1].”
Background
Metadata
- Authors
- Cherry, S. R.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2006-08-01
- Volume
- 8
- Issue
- 1
- Pages
- 35-62
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2150941474
- Cited by
- 188
- References
- 76
- FWCI
- 1.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.