MULTIMODALITY IN VIVO IMAGING SYSTEMS: Twice the Power or Double the Trouble?
The DOI matches its Crossref record; 76 of the 76 references it cites were found in a registry or an index.
Abstract
Many different types of radiation have been exploited to provide images of the structure and function of tissues inside a living subject. Each imaging modality is characterized by differing resolutions on the spatial and temporal scales, and by a different sensitivity for measuring properties related to morphology or function. Combinations of imaging modalities that integrate the strengths of two modalities, and at the same time eliminate one or more weaknesses of an individual modality, thus offer the prospect of improved diagnostics, therapeutic monitoring, and preclinical research using imaging approaches. This review discusses the advantages and challenges in developing multimodality imaging systems for in vivo use, highlights some successful combinations that are now routinely used in the clinic and in research, and discusses recent advances in multimodality instrumentation that may offer new opportunities for imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical tomography in medical imaging
Arridge, S. R. (1999) · Inverse Problems · doi:10.1088/0266-5611/15/2/022 · Cited by 2,524 · cited 1×
“raphy, is also being pursued for clinical applications, especially for breast imaging and neonatal brain imaging (94).”
Molecular imaging in living subjects: seeing fundamental biological processes in a new light
Massoud, T. F., & Gambhir, S. S. (2003) · Genes & Development · doi:10.1101/gad.1047403 · Cited by 2,216
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
The Essential Physics of Medical Imaging
Bushberg, J. T., Seibert, J. A., Leidholdt, E. M., Boone, J. M., & Goldschmidt, E. J. (2003) · Medical Physics · doi:10.1118/1.1585033 · Cited by 1,987
Wang, X., Pang, Y., Ku, G., Xie, X., Stoica, G., & Wang, L. V. (2003) · Nature Biotechnology · doi:10.1038/nbt839 · Cited by 1,700 · cited 1×
“Both structural and functional in vivo imaging have been accomplished with this technique (100).”
A combined PET/CT scanner for clinical oncology.
Beyer, T., Townsend, D. W., Brun, T., Kinahan, P. E., Charron, M., Roddy, R., Jerin, J., Young, J., Byars, L. G., & Nutt, R. (2000) · PubMed · Cited by 1,659
Quantitation in Positron Emission Computed Tomography: 1. Effect of Object Size
Hoffman, E. J., Huang, S.-C., & Phelps, M. E. (1979) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197906000-00001 · Cited by 1,143
Ntziachristos, V., Bremer, C., & Weissleder, R. (2003) · European Radiology · doi:10.1007/s00330-002-1524-x · Cited by 982 · cited 1×
“Several groups have been making excellent progress toward quantitative 3-D optical (89) fluorescence (90, 91) and bioluminescence tomography (92, 93).”
Attenuation correction for a combined 3D PET/CT scanner
Kinahan, P. E., Townsend, D. W., Beyer, T., & Sashin, D. (1998) · Medical Physics · doi:10.1118/1.598392 · Cited by 946 · cited 1×
“Approaches to map from CT-derived energy-averaged μ values to values appropriate for attenuation correction of PET or SPECT data arising from monoenergetic photons have therefore been developed (30, 31).”
Advances in In Vivo Bioluminescence Imaging of Gene Expression
Contag, C. H., & Bachmann, M. H. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.111901.093336 · Cited by 870 · cited 1×
“Optical imaging is the most widely utilized modality for preclinical molecular imaging, due in large part to easy accessibility of fluorescent probes and bioluminescent and fluorescent reporter proteins (87, 88).”
Molecular imaging in drug discovery and development
Rudin, M., & Weissleder, R. (2003) · Nature Reviews Drug Discovery · doi:10.1038/nrd1007 · Cited by 815
Concurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement
Ntziachristos, V., Yodh, A. G., Schnall, M., & Chance, B. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040570597 · Cited by 793 · cited 1×
“The system was used for contrast-enhanced diffuse optical tomography of the breast (95) and to perform MR-guided optical spectroscopy in breast lesions (96).”
Application of annihilation coincidence detection to transaxial reconstruction tomography.
Phelps, M. E., Hoffman, E. J., Mullani, N. A., & Ter‐Pogossian, M. M. (1975) · PubMed · Cited by 618
Levin, C. S., & Hoffman, E. J. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/3/019 · Cited by 551 · cited 1×
“most impact for very high-resolution small-animal studies using high-energy positron emitters, such as 124I and 15O, where positron range starts to become a dominant factor (80).”
X-ray-based attenuation correction for positron emission tomography/computed tomography scanners
Kinahan, P. E., Hasegawa, B. H., & Beyer, T. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127307 · Cited by 515
Huang, S.-C., Hoffman, E. J., Phelps, M. E., & Kuhl, D. E. (1979) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-197912000-00018 · Cited by 443
A submillimeter resolution fluorescence molecular imaging system for small animal imaging
Graves, E. E., Ripoll, J., Weissleder, R., & Ntziachristos, V. (2003) · Medical Physics · doi:10.1118/1.1568977 · Cited by 390 · cited 1×
“Several groups have been making excellent progress toward quantitative 3-D optical (89) fluorescence (90, 91) and bioluminescence tomography (92, 93).”
Simultaneous PET and MR imaging
Shao, Y., Cherry, S. R., Farahani, K., Meadors, K., Siegel, S., Silverman, R. W., & Marsden, P. K. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/10/010 · Cited by 374
Self-citationImaging Transgene Expression with Radionuclide Imaging Technologies
Gambhir, S. S., Herschman, H. R., Cherry, S. R., Barrio, J. R., Satyamurthy, N., Toyokuni, T., Phelps, M. E., Larson, S. M., Balatoni, J., Finn, R., et al. (2000) · Neoplasia · doi:10.1038/sj.neo.7900083 · Cited by 358 · cited 1×
“Novel targeted PET and SPECT radiopharmaceuticals, radiotracersequestering reporter gene systems (66), and labeling of therapeutic cells (67, 68) have opened up enormous opportunities for studying animal models of human disease and for testing new therapeutic strategies in vivo.”
Self-citationFour‐dimensional (4D) PET/CT imaging of the thorax
Nehmeh, S. A., Erdi, Y. E., Pan, T., Pevsner, A., Rosenzweig, K. E., Yorke, E., Mageras, G. S., Schoder, H., Vernon, P., Squire, O., et al. (2004) · Medical Physics · doi:10.1118/1.1809778 · Cited by 349 · cited 1×
“One possible solution to respiratory motion is to gate the PET or SPECT studies to the respiratory cycle (48); however, this results in a significant fraction of the data being rejected and a significant increase in imaging time for the same signal-to-noise level.”
Spatiotemporal mapping of brain activity by integration of multiple imaging modalities
Dale, A. M., & Halgren, E. (2001) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(00)00197-5 · Cited by 342 · cited 1×
“Monitoring the brain surface with high-density electroencephalography (EEG) or magnetoencephalography provides high temporal resolution (milliseconds); however, the electromagnetic fields mapped at the surface of the brain cannot unambiguously be reconstructed to provide the 3-D location of the sources of these fields…”
Adonai, N., Nguyen, K. N., Walsh, J., Iyer, M., Toyokuni, T., Phelps, M. E., McCarthy, T., McCarthy, D. W., & Gambhir, S. S. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.052709599 · Cited by 336 · cited 1×
“Novel targeted PET and SPECT radiopharmaceuticals, radiotracersequestering reporter gene systems (66), and labeling of therapeutic cells (67, 68) have opened up enormous opportunities for studying animal models of human disease and for testing new therapeutic strategies in vivo.”
In vivo molecular and genomic imaging: new challenges for imaging physics
Cherry, S. R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/3/r01 · Cited by 334
Self-citationPET-CT image co-registration in the thorax: influence of respiration
Goerres, G. W., Kamel, E., Heidelberg, T.-N. H., Schwitter, M. R., Burger, C., & von Schulthess, G. K. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-001-0710-4 · Cited by 332 · cited 1×
“The best match of the CT and PET/SPECT data appears to occur when the CT is acquired using a breath hold at end expiration (46, 47); however, this may not be possible for all patients because it is considerably more difficult than a deep inspiration breath-hold protocol.”
Imaging tri-fusion multimodality reporter gene expression in living subjects
Ray, P., De, A., Min, J.-J., Tsien, R. Y., & Gambhir, S. S. (2004) · Cancer Research · doi:10.1158/0008-5472.can-03-1816 · Cited by 329 · cited 1×
“A development that will likely impact multimodality imaging instrumentation is the rapid development in multimodality contrast agents (107, 108) and reporter genes (109).”
MRI-Guided Diffuse Optical Spectroscopy of Malignant and Benign Breast Lesions
Ntziachristos, V., Yodh, A. G., Schnall, M. D., & Chance, B. (2002) · Neoplasia · doi:10.1038/sj.neo.7900244 · Cited by 321 · cited 1×
“The system was used for contrast-enhanced diffuse optical tomography of the breast (95) and to perform MR-guided optical spectroscopy in breast lesions (96).”
Optical-based molecular imaging: contrast agents and potential medical applications
Bremer, C., Ntziachristos, V., & Weissleder, R. (2003) · European Radiology · doi:10.1007/s00330-002-1610-0 · Cited by 286 · cited 1×
“Optical imaging is the most widely utilized modality for preclinical molecular imaging, due in large part to easy accessibility of fluorescent probes and bioluminescent and fluorescent reporter proteins (87, 88).”
Lemieux, L., Salek-Haddadi, A., Josephs, O., Allen, P., Toms, N., Scott, C., Krakow, K., Turner, R., & Fish, D. R. (2001) · NeuroImage · doi:10.1006/nimg.2001.0853 · Cited by 277 · cited 1×
“There is clearly value, therefore, in combining these techniques, and it is now possible to simultaneously and continuously record EEG information within a magnet during the acquisition of fMRI data (102).”
Hyperspectral and multispectral bioluminescence optical tomography for small animal imaging
Chaudhari, A. J., Darvas, F., Bading, J. R., Moats, R. A., Conti, P. S., Smith, D. J., Cherry, S. R., & Leahy, R. M. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/23/001 · Cited by 273 · cited 1×
“Several groups have been making excellent progress toward quantitative 3-D optical (89) fluorescence (90, 91) and bioluminescence tomography (92, 93).”
Self-citationPET/CT scanners: A hardware approach to image fusion
Townsend, D. W., Beyer, T., & Blodgett, T. M. (2003) · Seminars in Nuclear Medicine · doi:10.1053/snuc.2003.127314 · Cited by 262 · cited 1×
“All commercial systems today are based on the “tandem” approach described above (28), where two separate imaging systems are combined in a single housing, and where the integration occurs at the level of the patient bed, with sophisticated software that integrates data acquisition, image reconstruction, data correctio…”
Ohnesorge, B., Flohr, T., Schwarz, K., Heiken, J. P., & Bae, K. T. (2000) · Medical Physics · doi:10.1118/1.598855 · Cited by 248 · cited 1×
“For CT alone, there are methods for minimizing truncation artifacts in reconstructed images (56, 57).”
Bayesian reconstruction and use of anatomical a priori information for emission tomography
Bowsher, J. E., Johnson, V. E., Turkington, T. G., Jaszczak, R. J., Floyd, C. E., & Coleman, R. E. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538945 · Cited by 237
Osman, M. M., Cohade, C., Nakamoto, Y., & Wahl, R. L. (2003) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-002-1024-x · Cited by 236 · cited 1×
“diaphragm but it also can cause significant artifacts in PET or SPECT images of the heart, lungs, and liver owing to errors in the attenuation correction (32, 44, 45).”
Bayesian reconstruction of functional images using anatomical information as priors
Gindi, G. R., Lee, M., Rangarajan, A., & Zubal, I. G. (1993) · IEEE Transactions on Medical Imaging · doi:10.1109/42.251117 · Cited by 231
Combining anatomy and function: the path to true image fusion
Townsend, D. W., & Cherry, S. R. (2001) · European Radiology · doi:10.1007/s003300101007 · Cited by 221 · cited 2×
“Widely used in PET and SPECT systems morphologic discrimination of MRI and the exquisite sensitivity of nuclear imaging, in both preclinical and clinical imaging (6).”
Self-citationMagneto/Optical Annexin V, a Multimodal Protein
Schellenberger, E. A., Sosnovik, D., Weissleder, R., & Josephson, L. (2004) · Bioconjugate Chemistry · doi:10.1021/bc049905i · Cited by 209
Kiessling, F., Greschus, S., Lichy, M. P., Bock, M., Fink, C., Vosseler, S., Moll, J., Mueller, M. M., Fusenig, N. E., Traupe, H., et al. (2004) · Nature Medicine · doi:10.1038/nm1101 · Cited by 205 · cited 1×
“Such a system has been developed (75), but its cost and size (even without dual-modality capability) may limit its installation to large research institutions and companies.”
Transmission scanning in emission tomography
Bailey, D. L. (1998) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590050282 · Cited by 202 · cited 1×
“Some form of transmission scanning has been incorporated into nuclear medicine imaging for well over 35 years (9).”
Focal tracer uptake: a potential artifact in contrast-enhanced dual-modality PET/CT scans.
Antoch, G., Freudenberg, L. S., Egelhof, T., Stattaus, J., Jentzen, W., Debatin, J. F., & Bockisch, A. (2002) · PubMed · Cited by 201
Respiration-induced Attenuation Artifact at PET/CT: Technical Considerations
Goerres, G. W., Burger, C., Kamel, E., Seifert, B., Kaim, A. H., Buck, A., Buehler, T. C., & von Schulthess, G. K. (2003) · Radiology · doi:10.1148/radiol.2263011732 · Cited by 198 · cited 1×
“diaphragm but it also can cause significant artifacts in PET or SPECT images of the heart, lungs, and liver owing to errors in the attenuation correction (32, 44, 45).”
Artifacts at PET and PET/CT Caused by Metallic Hip Prosthetic Material
Goerres, G. W., Ziegler, S. I., Burger, C., Berthold, T., von Schulthess, G. K., & Buck, A. (2003) · Radiology · doi:10.1148/radiol.2262012141 · Cited by 191
O’Donoghue, J. A., Zanzonico, P., Pugachev, A., Wen, B., Smith-Jones, P., Cai, S., Burnazi, E., Finn, R. D., Burgman, P., Ruan, S., et al. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.12.057 · Cited by 184
Mawlawi, O. R., Podoloff, D. A., Kohlmyer, S. G., Williams, J. J., Stearns, C. W., Culp, R. F., & Macapinlac, H. A. (2004) · PubMed · Cited by 184
Clinically feasible reconstruction of 3D whole-body PET/CT data using blurred anatomical labels
Comtat, C., Kinahan, P. E., Fessler, J. A., Beyer, T., Townsend, D. W., Defrise, M., & Michel, C. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/1/301 · Cited by 178
Description of a prototype emission-transmission computed tomography imaging system.
Lang, T., Hasegawa, B. H., Liew, S. C., Brown, J. K., Blankespoor, S. C., Reilly, S. M., Gingold, E. L., & Cann, C. E. (1992) · PubMed · Cited by 175
Boone, J. M., Shah, N., & Nelson, T. R. (2004) · Medical Physics · doi:10.1118/1.1636571 · Cited by 173 · cited 1×
“We are also involved in a project to develop a dedicated breast PET/CT scanner building on the platform of existing breast CT scanner (64) and breast PET scanner (65) prototypes.”
Blankespoor, S. C., Xu, X., Kaiki, K., Brown, J. K., Tang, H. R., Cann, C. E., & Hasegawa, B. H. (1996) · IEEE Transactions on Nuclear Science · doi:10.1109/23.531891 · Cited by 170
Image Analysis in Patients with Cancer Studied with a Combined PET and CT Scanner
CHARRON, M., BEYER, T., BOHNEN, N. N., KINAHAN, P. E., DACHILLE, M., JERIN, J., NUTT, R., MELTZER, C. C., VILLEMAGNE, V., & TOWNSEND, D. W. (2000) · Clinical Nuclear Medicine · doi:10.1097/00003072-200011000-00010 · Cited by 170 · cited 1×
“(PET/CT) (8), and they quickly demonstrated the combined power of these imaging modalities for clinical cancer imaging (20, 21) and for improved quantification of nuclear medicine research studies (22–24).”
Diffuse optical tomography with a priori anatomical information
Murat Guven, A., Yazıcı, B., Intes, X., & Chance, B. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/12/008 · Cited by 166 · cited 1×
“Anatomic information also is being used as a constraint in algorithms for 3-D optical tomography (97, 98), and these approaches would benefit from dual modality optical/structural imaging systems.”
Follow-up of women with breast cancer: comparison between MRI and FDG PET
Goerres, G. W., Michel, S. C. A., Fehr, M. K., Kaim, A. H., Steinert, H. C., Seifert, B., von Schulthess, G. K., & Huch, R. (2002) · European Radiology · doi:10.1007/s00330-002-1720-8 · Cited by 159
Dizendorf, E., Hany, T. F., Buck, A., von Schulthess, G. K., & Burger, C. (2003) · PubMed · Cited by 158
Meidenbauer, N., Marienhagen, J., Laumer, M., Vogl, S., Heymann, J., Andreesen, R., & Mackensen, A. (2003) · The Journal of Immunology · doi:10.4049/jimmunol.170.4.2161 · Cited by 157 · cited 1×
“Novel targeted PET and SPECT radiopharmaceuticals, radiotracersequestering reporter gene systems (66), and labeling of therapeutic cells (67, 68) have opened up enormous opportunities for studying animal models of human disease and for testing new therapeutic strategies in vivo.”
Head and neck imaging with PET and PET/CT: artefacts from dental metallic implants
Goerres, G. W., Hany, T. F., Kamel, E. M., von Schulthess, G. K., & Buck, A. (2002) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-001-0721-1 · Cited by 156
(2005) · PubMed · Cited by 156
Murthy, K., Aznar, M. C., Thompson, C. J., Loutfi, A., Lisbona, R., & Gagnon, J. H. (2000) · PubMed · Cited by 156
Incorporation of anatomical MR data for improved functional imaging with PET
Leahy, R. M., & Yan, X. (2005) · Springer eBooks · doi:10.1007/bfb0033746 · Cited by 154
Positron emission tomography/computed tomography?imaging protocols, artifacts, and pitfalls
Bockisch, A., Beyer, T., Antoch, G., Freudenberg, L., Kühl, H., Debatin, J. F., & MULLER, S. (2004) · Molecular Imaging and Biology · doi:10.1016/j.mibio.2004.04.006 · Cited by 145
Lipinski, B., Herzog, H. R., Kops, E. R., Oberschelp, W., & Müller-Gärtner, H.-W. (1997) · IEEE Transactions on Medical Imaging · doi:10.1109/42.563658 · Cited by 131
Incorporation of correlated structural images in PET image reconstruction
Ouyang, X., Wong, W. H., Johnson, V. E., Hu, X. P., & Chen, C. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.363105 · Cited by 118
Use of a magnetic field to increase the spatial resolution of positron emission tomography
Hammer, B. E., Christensen, N. L., & Heil, B. (1994) · Medical Physics · doi:10.1118/1.597178 · Cited by 115 · cited 1×
“range effects for several radionuclides of medical interest (76, 79).”
A study of artefacts in simultaneous PET and MR imaging using a prototype MR compatible PET scanner
Slates, R., Farahani, K., Shao, Y., Marsden, P. K., Taylor, J., Summers, P. E., Williams, S., Beech, J. S., & Cherry, S. R. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/8/312 · Cited by 112
Self-citationDo implanted pacemaker leads and ICD leads cause metal-related artifact in cardiac PET/CT?
DiFilippo, F. P., & Brunken, R. C. (2005) · PubMed · Cited by 112
Targeted Molecular Imaging Agents for Cellular-Scale Bimodal Imaging
Manning, H. C., Goebel, T. S., Thompson, R. C., Price, R. R., Lee, H., & Bornhop, D. J. (2004) · Bioconjugate Chemistry · doi:10.1021/bc049904q · Cited by 111 · cited 1×
“A development that will likely impact multimodality imaging instrumentation is the rapid development in multimodality contrast agents (107, 108) and reporter genes (109).”
Simultaneous molecular and anatomical imaging of the mousein vivo
Goertzen, A. L., Meadors, A. K., Silverman, R. W., & Cherry, S. R. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/24/301 · Cited by 104 · cited 1×
“This can be achieved relatively easily in a coplanar imaging system with some minor shielding of the PET detectors to prevent X-rays from entering the PET detectors (72).”
Self-citationPattern recognition approaches in biomedical and clinical magnetic resonance spectroscopy: a review
El‐Deredy, W. (1997) · NMR in Biomedicine · doi:10.1002/(sici)1099-1492(199705)10:3<138::aid-nbm474>3.0.co;2-h · Cited by 97 · cited 1×
“This system was used for simultaneous FDG PET and spin echo MRI studies in vivo (Figure 6), simultaneous FDG PET and NMR spectroscopy in an isolated, perfused rat heart preparation (84), and to assess artifacts in dual modality imaging at field strengths from 1.”
Erdi, Y. E., Nehmeh, S. A., Mulnix, T., Humm, J. L., & Watson, C. C. (2004) · PubMed · Cited by 93
Silva, A. J. D., Tang, H. R., Wong, K. H., Wu, M. C., Dae, M. W., & Hasegawa, B. H. (2001) · PubMed · Cited by 87
Object-specific attenuation correction of SPECT with correlated dual-energy X-ray CT
Hasegawa, B. H., Lang, T., Brown, J. K., Gingold, E. L., Reilly, S. M., Blankespoor, S. C., Liew, S. C., Tsui, B. M. W., & Ramanathan, C. (1993) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.1993.8526573 · Cited by 83 · cited 1×
“Z materials (33); however, this increases the complexity (and possibly the dose) of”
Three-dimensional optical tomographic brain imaging in small animals, part 1: hypercapnia
Bluestone, A. Y., Stewart, M., Lasker, J., Abdoulaev, G. S., & Hielscher, A. H. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1784471 · Cited by 73 · cited 1×
“Several groups have been making excellent progress toward quantitative 3-D optical (89) fluorescence (90, 91) and bioluminescence tomography (92, 93).”
Detector concept for OPET-a combined PET and optical imaging system
Prout, D. L., Silverman, R. W., & Chatziioannou, A. F. (2004) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2004.829736 · Cited by 63 · cited 1×
“have been investigating detector designs that are capable of detecting the faint bioluminescence signals from luciferase reporter genes and can also efficiently convert the 511 keV annihilation photons emitted from PET radiotracers into light utilizing transparent scintillators (99).”
Neuroblastoma imaging using a combined CT scanner-scintillation camera and 131I-MIBG.
Tang, H. R., Silva, A. J. D., Matthay, K. K., Price, D. C., Huberty, J. P., Hawkins, R. A., & Hasegawa, B. H. (2001) · PubMed · Cited by 61
The use of X-ray CT for attenuation correction of PET data
Beyer, T., Kinahan, P. E., Townsend, D. W., & Sashin, D. (2002) · IEEE Nuclear Science Symposium and Medical Imaging Conference (NSS/MIC) · doi:10.1109/nssmic.1994.474762 · Cited by 60 · cited 1×
“Approaches to map from CT-derived energy-averaged μ values to values appropriate for attenuation correction of PET or SPECT data arising from monoenergetic photons have therefore been developed (30, 31).”
Humm, J. L., Ballon, D., Hu, Y., Ruan, S., Chui, C. S., Tulipano, P. K., Erdi, A. K., Koutcher, J. A., Zakian, K. L., Urano, M., et al. (2003) · Medical Physics · doi:10.1118/1.1600738 · Cited by 55
Tang, H. R., Brown, J. K., Silva, A. J. D., Matthay, K. K., Price, D. C., Huberty, J. P., Hawkins, R. A., & Hasegawa, B. H. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.775578 · Cited by 45
The effect of oral contrast on large bowel activity in FDG-PET/CT
Otsuka, H., Graham, M. M., Kubo, A., & Nishitani, H. (2005) · Annals of Nuclear Medicine · doi:10.1007/bf03027388 · Cited by 31
Use of X-ray CT-defined regions of interest for the determination of SPECT recovery coefficients
Tang, H. R., Brown, J. K., & Hasegawa, B. H. (1997) · IEEE Transactions on Nuclear Science · doi:10.1109/23.632738 · Cited by 22
Cited by
Nanoprobes with near-infrared persistent luminescence for in vivo imaging
le Masne de Chermont, Q., Chanéac, C., Seguin, J., Pellé, F., Maîtrejean, S., Jolivet, J.-P., Gourier, D., Bessodes, M., & Scherman, D. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0702427104 · Cited by 834
Molecular Imaging by Means of Multispectral Optoacoustic Tomography (MSOT)
Ntziachristos, V., & Razansky, D. (2010) · Chemical Reviews · doi:10.1021/cr9002566 · Cited by 776
Nanogels: An overview of properties, biomedical applications and obstacles to clinical translation
Soni, K. S., Desale, S. S., & Bronich, T. K. (2016) · Journal of Controlled Release · doi:10.1016/j.jconrel.2015.11.009 · Cited by 683
Nanoparticles in magnetic resonance imaging: from simple to dual contrast agents
Busquets, M. A., Estelrich, J., & Sánchez-Martín, M. J. (2015) · International Journal of Nanomedicine · doi:10.2147/ijn.s76501 · Cited by 622
Hydrogels as intelligent materials: A brief review of synthesis, properties and applications
Mahinroosta, M., Jomeh Farsangi, Z., Allahverdi, A., & Shakoori, Z. (2018) · Materials Today Chemistry · doi:10.1016/j.mtchem.2018.02.004 · Cited by 551
Metadata
- Authors
- Cherry, S. R.
- Venue
- Annual Review of Biomedical Engineering
- Publisher
- Annual Reviews
- Published
- 2006-08-01
- Volume
- 8
- Issue
- 1
- Pages
- 35-62
- ISSN
- 1523-9829 (ISSN-L)
- 1545-4274
- OpenAlex
- W2150941474
- Cited by
- 188
- References
- 76
- FWCI
- 1.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.