Microfluidic Large-Scale Integration: The Evolution of Design Rules for Biological Automation
The DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Microfluidic large-scale integration (mLSI) refers to the development of microfluidic chips with thousands of integrated micromechanical valves and control components. This technology is utilized in many areas of biology and chemistry and is a candidate to replace today's conventional automation paradigm, which consists of fluid-handling robots. We review the basic development of mLSI and then discuss design principles of mLSI to assess the capabilities and limitations of the current state of the art and to facilitate the application of mLSI to areas of biology. Many design and practical issues, including economies of scale, parallelization strategies, multiplexing, and multistep biochemical processing, are discussed. Several microfluidic components used as building blocks to create effective, complex, and highly integrated microfluidic networks are also highlighted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687 · cited 1×
“Numerous applications of microfluidics have been developed in chemistry, biology, and other fields (6, 7, 37, 49).”
BackgroundMicrofluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Self-citationMonolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Self-citationChaotic Mixer for Microchannels
Stroock, A. D., Dertinger, S. K. W., Ajdari, A., Mezić, I., Stone, H. A., & Whitesides, G. M. (2002) · Science · doi:10.1126/science.1066238 · Cited by 3,435
Solvent Compatibility of Poly(dimethylsiloxane)-Based Microfluidic Devices
Lee, J. N., Park, C., & Whitesides, G. M. (2003) · Analytical Chemistry · doi:10.1021/ac0346712 · Cited by 2,643
Microfluidic Large-Scale Integration
Thorsen, T., Maerkl, S. J., & Quake, S. R. (2002) · Science · doi:10.1126/science.1076996 · Cited by 2,222
Self-citationLab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Micromachined Transducers Sourcebook
Kovacs, G. T. A. (1998) · Cited by 1,200
From Micro- to Nanofabrication with Soft Materials
Quake, S. R., & Scherer, A. (2000) · Science · doi:10.1126/science.290.5496.1536 · Cited by 1,131
Self-citationMicro Total Analysis Systems. Latest Advancements and Trends
Dittrich, P. S., Tachikawa, K., & Manz, A. (2006) · Analytical Chemistry · doi:10.1021/ac0605602 · Cited by 950
Cited by
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Advantages and challenges of microfluidic cell culture in polydimethylsiloxane devices
Halldorsson, S., Lucumi, E., Gómez-Sjöberg, R., & Fleming, R. M. T. (2015) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2014.07.029 · Cited by 1,027
“…(Plessy et al., 2013), lab-on-chip platforms (Mark et al., 2010; Ni et al., 2009), large-scale integration and biological automation (Melin and Quake, 2007), micro total analysis systems (Kovarik et al., 2012), drug research (Wu et al., 2010), cellular separations (Bhagat et…”
BackgroundMaking it stick: convection, reaction and diffusion in surface-based biosensors
Squires, T. M., Messinger, R. J., & Manalis, S. R. (2008) · Nature Biotechnology · doi:10.1038/nbt1388 · Cited by 986
Prebiotic Systems Chemistry: New Perspectives for the Origins of Life
Ruiz-Mirazo, K., Briones, C., & de la Escosura, A. (2014) · Chemical Reviews · doi:10.1021/cr2004844 · Cited by 930
Au, A. K., Huynh, W., Horowitz, L. F., & Folch, A. (2016) · Angewandte Chemie International Edition · doi:10.1002/anie.201504382 · Cited by 788
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Microfluidic Chips for Point‐of‐Care Immunodiagnostics
Gervais, L., de Rooij, N., & Delamarche, E. (2011) · Advanced Materials · doi:10.1002/adma.201100464 · Cited by 491
Mehling, M., & Tay, S. (2014) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2013.10.005 · Cited by 390
High Throughput Gene Expression Measurement with Real Time PCR in a Microfluidic Dynamic Array
Spurgeon, S. L., Jones, R. C., & Ramakrishnan, R. (2008) · PLoS ONE · doi:10.1371/journal.pone.0001662 · Cited by 386
Bavli, D., Prill, S., Ezra, E., Levy, G., Cohen, M., Vinken, M., Vanfleteren, J., Jaeger, M., & Nahmias, Y. (2016) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1522556113 · Cited by 362
Droplet microfluidics: recent developments and future applications
Casadevall i Solvas, X., & deMello, A. (2011) · Chem. Commun. · doi:10.1039/c0cc02474k · Cited by 353
Biomedical microfluidic devices by using low-cost fabrication techniques: A review
Faustino, V., Catarino, S. O., Lima, R., & Minas, G. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.11.031 · Cited by 338
Industrial lab-on-a-chip: Design, applications and scale-up for drug discovery and delivery
Vladisavljević, G. T., Khalid, N., Neves, M. A., Kuroiwa, T., Nakajima, M., Uemura, K., Ichikawa, S., & Kobayashi, I. (2013) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.017 · Cited by 313
Advances in microfluidic PCR for point-of-care infectious disease diagnostics
Park, S., Zhang, Y., Lin, S., Wang, T.-H., & Yang, S. (2011) · Biotechnology Advances · doi:10.1016/j.biotechadv.2011.06.017 · Cited by 299
Rohde, C. B., Zeng, F., Gonzalez-Rubio, R., Angel, M., & Yanik, M. F. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0706513104 · Cited by 295
Microfluidics for cell-based high throughput screening platforms—A review
Du, G., Fang, Q., & den Toonder, J. M. J. (2016) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.11.023 · Cited by 276
Microfluidic-based biosensors toward point-of-care detection of nucleic acids and proteins
Choi, S., Goryll, M., Sin, L. Y. M., Wong, P. K., & Chae, J. (2011) · Microfluidics and Nanofluidics · doi:10.1007/s10404-010-0638-8 · Cited by 270
Ferrofluids for Fabrication of Remotely Controllable Micro‐Nanomachines by Two‐Photon Polymerization
Xia, H., Wang, J., Tian, Y., Chen, Q., Du, X., Zhang, Y., He, Y., & Sun, H. (2010) · Advanced Materials · doi:10.1002/adma.201000542 · Cited by 265
3D printing of versatile reactionware for chemical synthesis
Kitson, P. J., Glatzel, S., Chen, W., Lin, C.-G., Song, Y.-F., & Cronin, L. (2016) · Nature Protocols · doi:10.1038/nprot.2016.041 · Cited by 217
Satellite remote sensing of aerosol optical depth: advances, challenges, and perspectives
Wei, X., Chang, N.-B., Bai, K., & Gao, W. (2020) · Critical Reviews in Environmental Science and Technology · doi:10.1080/10643389.2019.1665944 · Cited by 215
“…et al., 2003; Xue et al., 2014), the empirical orthogonal functions (Liu, Pinker, & Holben, 2005), the linear or second-order polynomial functions (Melin & Quake, 2007), the arithmetic and weighted average method (Gupta & Christopher, 2008), the least squares estimation (Guo et al., 2013), the…”
MethodLagus, T. P., & Edd, J. F. (2013) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/46/11/114005 · Cited by 213
“and valves [2] in depth, we focus this section on droplet”
BackgroundMicrofluidics separation reveals the stem-cell–like deformability of tumor-initiating cells
Zhang, W., Kai, K., Choi, D. S., Iwamoto, T., Nguyen, Y. H., Wong, H., Landis, M. D., Ueno, N. T., Chang, J., & Qin, L. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1209893109 · Cited by 208
Micro- and nanofluidic systems for high-throughput biological screening
Hong, J., Edel, J. B., & deMello, A. J. (2009) · Drug Discovery Today · doi:10.1016/j.drudis.2008.10.001 · Cited by 205
Miniaturization and Parallelization of Biological and Chemical Assays in Microfluidic Devices
Vyawahare, S., Griffiths, A. D., & Merten, C. A. (2010) · Chemistry & Biology · doi:10.1016/j.chembiol.2010.09.007 · Cited by 167
Kim, S. B., Zhang, Y., Won, S. M., Bandodkar, A. J., Sekine, Y., Xue, Y., Koo, J., Harshman, S. W., Martin, J. A., Park, J. M., et al. (2018) · Small · doi:10.1002/smll.201703334 · Cited by 167
Gao, D., Liu, H., Lin, J.-M., Wang, Y., & Jiang, Y. (2013) · Lab on a Chip · doi:10.1039/c2lc41215b · Cited by 135
Nanotechnology: emerging tools for biology and medicine
Wong, I. Y., Bhatia, S. N., & Toner, M. (2013) · Genes & Development · doi:10.1101/gad.226837.113 · Cited by 132
Gomez-Sjoberg, R., Leyrat, A. A., Houseman, B. T., Shokat, K., & Quake, S. R. (2010) · Analytical Chemistry · doi:10.1021/ac101870s · Cited by 104
Self-citationEngineering of synthetic cellular microenvironments: Implications for immunity
Adutler-Lieber, S., Zaretsky, I., Platzman, I., Deeg, J., Friedman, N., Spatz, J. P., & Geiger, B. (2014) · Journal of Autoimmunity · doi:10.1016/j.jaut.2014.05.003 · Cited by 39
“medium exchange during an experiment [111], or generation of precise chemical and thermal gradients [112]; thus, microfabricated”
Background
Metadata
- Authors
- Melin, J., & Quake, S. R.
- Venue
- Annual Review of Biophysics and Biomolecular Structure
- Publisher
- Annual Reviews
- Published
- 2007-06-01
- Volume
- 36
- Issue
- 1
- Pages
- 213-231
- ISSN
- 1056-8700 (ISSN-L)
- 1545-4266
- OpenAlex
- W2110460556
- Cited by
- 738
- References
- 38
- FWCI
- 28.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.