Low-Temperature Degradation of Zirconia and Implications for Biomedical Implants
The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Abstract
This review describes the mechanisms responsible for low-temperature degradation (LTD) of zirconia ceramics and its detrimental consequences for biomedical devices. Special emphasis is given to the critical issue of zirconia degradation actually observed for hip prostheses. Experimental methods to accurately measure and predict LTD in a given zirconia ceramic are presented. Different solutions to inhibit LTD or at least reduce its kinetics are reviewed, with the objective of highlighting alternative options for the generation of new zirconia-based biomedical ceramic devices.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Theory of Transformations in Metals and Alloys
Christian, J. W., & Otte, H. M. (1966) · Physics Today · doi:10.1063/1.3048417 · Cited by 3,232
GARVIE, R. C., HANNINK, R. H., & PASCOE, R. T. (1975) · Nature · doi:10.1038/258703a0 · Cited by 2,291
Phase Analysis in Zirconia Systems
Garvie, R. C., & Nicholson, P. S. (1972) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1972.tb11290.x · Cited by 1,614
Phase relationships in the zirconia-yttria system
Scott, H. G. (1975) · Journal of Materials Science · doi:10.1007/bf01031853 · Cited by 1,282
What future for zirconia as a biomaterial?
Chevalier, J. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.07.034 · Cited by 1,228
Self-citationLow‐Temperature Aging of Y‐TZP Ceramics
Chevalier, J., Cales, B., & Drouin, J. M. (1999) · Journal of the American Ceramic Society · doi:10.1111/j.1151-2916.1999.tb02055.x · Cited by 713
Self-citationDe Aza, A. H., Chevalier, J., Fantozzi, G., Schehl, M., & Torrecillas, R. (2002) · Biomaterials · doi:10.1016/s0142-9612(01)00206-x · Cited by 625
Self-citationTransformation Toughening of Ceramics
Green, D. J., Hannink, R. H. J., & Swain, M. V. (2018) · CRC Press eBooks · doi:10.1201/9781351077408 · Cited by 585
Chevalier, J., Deville, S., Münch, E., Jullian, R., & Lair, F. (2004) · Biomaterials · doi:10.1016/j.biomaterials.2004.01.002 · Cited by 385
Self-citationDeville, S., Chevalier, J., & Gremillard, L. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.11.021 · Cited by 295
Self-citation
Cited by
The Tetragonal‐Monoclinic Transformation in Zirconia: Lessons Learned and Future Trends
Chevalier, J., Gremillard, L., Virkar, A. V., & Clarke, D. R. (2009) · Journal of the American Ceramic Society · doi:10.1111/j.1551-2916.2009.03278.x · Cited by 1,609
Self-citationCeramics for medical applications: A picture for the next 20 years
Chevalier, J., & Gremillard, L. (2009) · Journal of the European Ceramic Society · doi:10.1016/j.jeurceramsoc.2008.08.025 · Cited by 754
Self-citationLughi, V., & Sergo, V. (2010) · Dental Materials · doi:10.1016/j.dental.2010.04.006 · Cited by 692
Strength, toughness and aging stability of highly-translucent Y-TZP ceramics for dental restorations
Zhang, F., Inokoshi, M., Batuk, M., Hadermann, J., Naert, I., Van Meerbeek, B., & Vleugels, J. (2016) · Dental Materials · doi:10.1016/j.dental.2016.09.025 · Cited by 418
An overview of recent advances in designing orthopedic and craniofacial implants
Mantripragada, V. P., Lecka‐Czernik, B., Ebraheim, N. A., & Jayasuriya, A. C. (2013) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.34605 · Cited by 273
Ultrafast laser welding of ceramics
Penilla, E. H., Devia-Cruz, L. F., Wieg, A. T., Martinez-Torres, P., Cuando-Espitia, N., Sellappan, P., Kodera, Y., Aguilar, G., & Garay, J. E. (2019) · Science · doi:10.1126/science.aaw6699 · Cited by 224
Zirconia in Fixed Implant Prosthodontics
Guess, P. C., Att, W., & Strub, J. R. (2012) · Clinical Implant Dentistry and Related Research · doi:10.1111/j.1708-8208.2010.00317.x · Cited by 192
“In addition, concerns regarding the long-term stability of zirconia have led to controversial discussions regarding the utilization of zirconia as a substitute for alloys in implant dentistry.(10,11) Compendious information about the properties and outcome of zirconia-based implantsupported restorations would provide…”
BackgroundInfluence of sintering conditions on low-temperature degradation of dental zirconia
Inokoshi, M., Zhang, F., De Munck, J., Minakuchi, S., Naert, I., Vleugels, J., Van Meerbeek, B., & Vanmeensel, K. (2014) · Dental Materials · doi:10.1016/j.dental.2014.03.005 · Cited by 185
“transformation of the metastable tetragonal to the monoclinic phase (at 20–250 ◦C), initiated and accelerated by water penetration [4–6].”
BackgroundMakhija, S. K., Lawson, N. C., Gilbert, G. H., Litaker, M. S., McClelland, J. A., Louis, D. R., Gordan, V. V., Pihlstrom, D. J., Meyerowitz, C., Mungia, R., et al. (2016) · Journal of Dentistry · doi:10.1016/j.jdent.2016.09.010 · Cited by 175
“opaqueness and fear of long-term strength degradation from low temperature degradation [5].”
BackgroundRevolution of Current Dental Zirconia: A Comprehensive Review
Alqutaibi, A. Y., Ghulam, O., Krsoum, M., Binmahmoud, S., Taher, H., Elmalky, W., & Zafar, M. S. (2022) · Molecules · doi:10.3390/molecules27051699 · Cited by 142
“The occurrence of multiple oxygen vacancies in the Zir lattice is facilitated by the triatomic property of yttrium, which leads to water molecules in its structure [45].”
BackgroundDimitriadis, K., Sfikas, A. K., Kamnis, S., Tsolka, P., & Agathopoulos, S. (2022) · The Journal of Advanced Prosthodontics · doi:10.4047/jap.2022.14.2.96 · Cited by 25
Metadata
- Authors
- Chevalier, J., Gremillard, L., & Deville, S.
- Venue
- Annual Review of Materials Research
- Publisher
- Annual Reviews
- Published
- 2007-08-01
- Volume
- 37
- Issue
- 1
- Pages
- 1-32
- ISSN
- 1531-7331 (ISSN-L)
- 1545-4118
- OpenAlex
- W2140625128
- Cited by
- 741
- References
- 14
- FWCI
- 2.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.