MRI-guided focused ultrasound (MRgFUS) surgery is a noninvasive thermal ablation method that uses magnetic resonance imaging (MRI) for target definition, treatment planning, and closed-loop control of energy deposition. Integrating FUS and MRI as a therapy delivery system allows us to localize, target, and monitor in real time, and thus to ablate targeted tissue without damaging normal structures. This precision makes MRgFUS an attractive alternative to surgical resection or radiation therapy of benign and malignant tumors. Already approved for the treatment of uterine fibroids, MRgFUS is in ongoing clinical trials for the treatment of breast, liver, prostate, and brain cancer and for the palliation of pain in bone metastasis. In addition to thermal ablation, FUS, with or without the use of microbubbles, can temporarily change vascular or cell membrane permeability and release or activate various compounds for targeted drug delivery or gene therapy. A disruptive technology, MRgFUS provides new therapeutic approaches and may cause major changes in patient management and several medical disciplines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal dose determination in cancer therapy
Sapareto, S. A., & Dewey, W. C. (1984) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/0360-3016(84)90379-1 · Cited by 2,498
Noninvasive MR Imaging–guided Focal Opening of the Blood-Brain Barrier in Rabbits
Hynynen, K., McDannold, N., Vykhodtseva, N., & Jolesz, F. A. (2001) · Radiology · doi:10.1148/radiol.2202001804 · Cited by 1,456
Self-citationMoritz, A. R., & Henriques, F. C. (1947) · PubMed · Cited by 1,289
Comprehensive compilation of empirical ultrasonic properties of mammalian tissues
Goss, S. A., Johnston, R. L., & Dunn, F. (1978) · The Journal of the Acoustical Society of America · doi:10.1121/1.382016 · Cited by 1,115
Ultrasound-Enhanced Systemic Thrombolysis for Acute Ischemic Stroke
Alexandrov, A. V., Molina, C. A., Grotta, J. C., Garami, Z., Ford, S. R., Alvarez-Sabin, J., Montaner, J., Saqqur, M., Demchuk, A. M., Moyé, L. A., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa041175 · Cited by 1,046
Healing sound: the use of ultrasound in drug delivery and other therapeutic applications
Mitragotri, S. (2005) · Nature Reviews Drug Discovery · doi:10.1038/nrd1662 · Cited by 980
A NEW METHOD FOR THE GENERATION AND USE OF FOCUSED ULTRASOUND IN EXPERIMENTAL BIOLOGY
Lynn, J. G., Zwemer, R. L., Chick, A. J., & Miller, A. E. (1942) · Journal of General Physiology · doi:10.1085/jgp.26.2.179 · Cited by 690
Hynynen, K., McDannold, N., Sheikov, N. A., Jolesz, F. A., & Vykhodtseva, N. (2005) · NeuroImage · doi:10.1016/j.neuroimage.2004.06.046 · Cited by 679 · cited 3×
“In this method, the tissue is deformed, typically by either a low-frequency shear wave (73) or a quasistatic compression (74), and the resulting tissue displacement is mapped using motion-sensitive MRI sequences.”
BackgroundMethodSelf-citationKinoshita, M., McDannold, N., Jolesz, F. A., & Hynynen, K. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604318103 · Cited by 645
Self-citationMR Imaging-guided Focused Ultrasound Surgery of Fibroadenomas in the Breast: A Feasibility Study
Hynynen, K., Pomeroy, O., Smith, D. N., Huber, P. E., McDannold, N. J., Kettenbach, J., Baum, J., Singer, S., & Jolesz, F. A. (2001) · Radiology · doi:10.1148/radiology.219.1.r01ap02176 · Cited by 634
Self-citation
Cited by
Overview of Therapeutic Ultrasound Applications and Safety Considerations
Miller, D. L., Smith, N. B., Bailey, M. R., Czarnota, G. J., Hynynen, K., Makin, I. R. S., & Bioeffects Committee of the American Institute of Ultrasound in Medicine (2012) · Journal of Ultrasound in Medicine · doi:10.7863/jum.2012.31.4.623 · Cited by 752
High intensity focused ultrasound in clinical tumor ablation
Zhou, Y.-F. (2011) · World Journal of Clinical Oncology · doi:10.5306/wjco.v2.i1.8 · Cited by 625
Izadifar, Z., Izadifar, Z., Chapman, D., & Babyn, P. (2020) · Journal of Clinical Medicine · doi:10.3390/jcm9020460 · Cited by 457
“HIFU treatment is usually guided, assessed, and monitored by either magnetic resonance imaging (MRI) or ultrasound imaging [5].”
BackgroundA review of low-intensity focused ultrasound pulsation
Bystritsky, A., Korb, A. S., Douglas, P. K., Cohen, M. S., Melega, W. P., Mulgaonkar, A. P., DeSalles, A., Min, B.-K., & Yoo, S.-S. (2011) · Brain Stimulation · doi:10.1016/j.brs.2011.03.007 · Cited by 409
Advances in transdermal insulin delivery
Zhang, Y., Yu, J., Kahkoska, A. R., Wang, J., Buse, J. B., & Gu, Z. (2019) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2018.12.006 · Cited by 325
van den Bijgaart, R. J. E., Eikelenboom, D. C., Hoogenboom, M., Fütterer, J. J., den Brok, M. H., & Adema, G. J. (2017) · Cancer Immunology, Immunotherapy · doi:10.1007/s00262-016-1891-9 · Cited by 276
Naor, O., Krupa, S., & Shoham, S. (2016) · Journal of Neural Engineering · doi:10.1088/1741-2560/13/3/031003 · Cited by 228
Opening doors with ultrasound and microbubbles: Beating biological barriers to promote drug delivery
Deprez, J., Lajoinie, G., Engelen, Y., De Smedt, S. C., & Lentacker, I. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.02.015 · Cited by 207
Multiplexed imaging for diagnosis and therapy
Heinzmann, K., Carter, L. M., Lewis, J. S., & Aboagye, E. O. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0131-8 · Cited by 168
Lipid monolayer collapse and microbubble stability
Kwan, J. J., & Borden, M. A. (2012) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2012.08.005 · Cited by 162
High-intensity focused ultrasound: Principles, therapy guidance, simulations and applications
Jenne, J. W., Preusser, T., & Günther, M. (2012) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2012.07.001 · Cited by 159
Liu, Z., Lammers, T., Ehling, J., Fokong, S., Bornemann, J., Kiessling, F., & Gätjens, J. (2011) · Biomaterials · doi:10.1016/j.biomaterials.2011.05.019 · Cited by 158
de Maar, J. S., Sofias, A. M., Porta Siegel, T., Vreeken, R. J., Moonen, C., Bos, C., & Deckers, R. (2020) · Theranostics · doi:10.7150/thno.38625 · Cited by 71
Revolutionizing Neurology: The Role of Artificial Intelligence in Advancing Diagnosis and Treatment
Kalani, M., & Anjankar, A. (2024) · Cureus · doi:10.7759/cureus.61706 · Cited by 48
Metadata
- Authors
- Jolesz, F. A.
- Venue
- Annual Review of Medicine
- Publisher
- Annual Reviews
- Published
- 2009-02-01
- Volume
- 60
- Issue
- 1
- Pages
- 417-430
- ISSN
- 0066-4219 (ISSN-L)
- 1545-326X
- OpenAlex
- W2147130865
- Cited by
- 377
- References
- 71
- FWCI
- 1.85
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.