Patch Clamp Techniques for Studying Ionic Channels in Excitable Membranes
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
Macrophage polarization refers to how macrophages have been activated at a given point in space and time. Polarization is not fixed, as macrophages are sufficiently plastic to integrate multiple signals, such as those from microbes, damaged tissues, and ...Read More
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hamill, O. P., Marty, A., Neher, E., Sakmann, B., & Sigworth, F. J. (1981) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/bf00656997 · Cited by 18,436
Self-citationSingle-channel currents recorded from membrane of denervated frog muscle fibres
NEHER, E., & SAKMANN, B. (1976) · Nature · doi:10.1038/260799a0 · Cited by 2,570
Self-citationSodium and calcium channels in bovine chromaffin cells
Fenwick, E. M., Marty, A., & Neher, E. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014394 · Cited by 961
Self-citationProperties of single calcium‐activated potassium channels in cultured rat muscle
Barrett, J. N., Magleby, K. L., & Pallotta, B. S. (1982) · The Journal of Physiology · doi:10.1113/jphysiol.1982.sp014370 · Cited by 709
Inward current channels activated by intracellular Ca in cultured cardiac cells
Colquhoun, D., Neher, E., Reuter, H., & Stevens, C. F. (1981) · Nature · doi:10.1038/294752a0 · Cited by 678
Self-citationCa-dependent K channels with large unitary conductance in chromaffin cell membranes
Marty, A. (1981) · Nature · doi:10.1038/291497a0 · Cited by 652
Serotonin and cyclic AMP close single K+ channels in Aplysia sensory neurones
Siegelbaum, S. A., Camardo, J. S., & Kandel, E. R. (1982) · Nature · doi:10.1038/299413a0 · Cited by 651
Relaxation and fluctuations of membrane currents that flow through drug-operated channels
Colquhoun, D., & Hawkes, A. G. (1977) · Proceedings of the Royal Society of London. Series B. Biological Sciences · doi:10.1098/rspb.1977.0137 · Cited by 622
Sakmann, B., Patlak, J., & Neher, E. (1980) · Nature · doi:10.1038/286071a0 · Cited by 600
Self-citationTight-Seal Whole-Cell Recording
Marty, A., & Neher, E. (1983) · Single-Channel Recording · doi:10.1007/978-1-4615-7858-1_7 · Cited by 580
Self-citation
Cited by
Reversible Photocontrol of Biological Systems by the Incorporation of Molecular Photoswitches
Szymański, W., Beierle, J. M., Kistemaker, H. A. V., Velema, W. A., & Feringa, B. L. (2013) · Chemical Reviews · doi:10.1021/cr300179f · Cited by 1,239
Multi-electrode array technologies for neuroscience and cardiology
Spira, M. E., & Hai, A. (2013) · Nature Nanotechnology · doi:10.1038/nnano.2012.265 · Cited by 991
Three-Dimensional, Flexible Nanoscale Field-Effect Transistors as Localized Bioprobes
Tian, B., Cohen-Karni, T., Qing, Q., Duan, X., Xie, P., & Lieber, C. M. (2010) · Science · doi:10.1126/science.1192033 · Cited by 798
Pethig, R., & Kell, D. B. (1987) · Physics in Medicine and Biology · doi:10.1088/0031-9155/32/8/001 · Cited by 796
Neural recording and modulation technologies
Chen, R., Canales, A., & Anikeeva, P. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.93 · Cited by 655
Electrolyte transport in the mammalian colon: mechanisms and implications for disease
Kunzelmann, K., & Mall, M. (2002) · Physiological Reviews · doi:10.1152/physrev.00026.2001 · Cited by 655
Trube, G., Rorsman, P., & Ohno-Shosaku, T. (1986) · Pfl�gers Archiv European Journal of Physiology · doi:10.1007/bf00657506 · Cited by 572
A Review on Macroscale and Microscale Cell Lysis Methods
Shehadul Islam, M., Aryasomayajula, A., & Selvaganapathy, P. (2017) · Micromachines · doi:10.3390/mi8030083 · Cited by 541
Okamura, H., Aramburu, J., García-Rodríguez, C., Viola, J. P. B., Raghavan, A., Tahiliani, M., Zhang, X., Qin, J., Hogan, P. G., & Rao, A. (2000) · Molecular Cell · doi:10.1016/s1097-2765(00)00053-8 · Cited by 481
Single-cell analysis tools for drug discovery and development
Heath, J. R., Ribas, A., & Mischel, P. S. (2016) · Nature Reviews Drug Discovery · doi:10.1038/nrd.2015.16 · Cited by 473
Biosensor technology: recent advances in threat agent detection and medicine
Kirsch, J., Siltanen, C., Zhou, Q., Revzin, A., & Simonian, A. (2013) · Chemical Society Reviews · doi:10.1039/c3cs60141b · Cited by 462
Intracellular recordings of action potentials by an extracellular nanoscale field-effect transistor
Duan, X., Gao, R., Xie, P., Cohen-Karni, T., Qing, Q., Choe, H. S., Tian, B., Jiang, X., & Lieber, C. M. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2011.223 · Cited by 456
Calcium channels: Molecular pharmacology, structure and regulation
Hosey, M. M., & Lazdunski, M. (1988) · The Journal of Membrane Biology · doi:10.1007/bf01870922 · Cited by 380
Fabrication and Use of Nanometer-Sized Electrodes in Electrochemistry
Penner, R. M., Heben, M. J., Longin, T. L., & Lewis, N. S. (1990) · Science · doi:10.1126/science.250.4984.1118 · Cited by 356
Applications of biological pores in nanomedicine, sensing, and nanoelectronics
Majd, S., Yusko, E. C., Billeh, Y. N., Macrae, M. X., Yang, J., & Mayer, M. (2010) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2010.05.002 · Cited by 327
Location of a δ-subunit region determining ion transport through the acetylcholine receptor channel
Imoto, K., Methfessel, C., Sakmann, B., Mishina, M., Mori, Y., Konno, T., Fukuda, K., Kurasaki, M., Bujo, H., Fujita, Y., et al. (1986) · Nature · doi:10.1038/324670a0 · Cited by 315
Self-citationIn-cell recordings by extracellular microelectrodes
Hai, A., Shappir, J., & Spira, M. E. (2010) · Nature Methods · doi:10.1038/nmeth.1420 · Cited by 270
Role of acetylcholine receptor subunits in gating of the channel
Sakmann, B., Methfessel, C., Mishina, M., Takahashi, T., Takai, T., Kurasaki, M., Fukuda, K., & Numa, S. (1985) · Nature · doi:10.1038/318538a0 · Cited by 270
Self-citationStructural Elements Involved in Specific K+ Channel Functions
Jan, L. Y., & Jan, Y. N. (1992) · Annual Review of Physiology · doi:10.1146/annurev.ph.54.030192.002541 · Cited by 270
Voltage-sensitive ion channels
Jan, L. Y., & Jan, Y. N. (1989) · Cell · doi:10.1016/0092-8674(89)90979-3 · Cited by 263
Electrical stimulation to accelerate wound healing
Thakral, G., LaFontaine, J., Najafi, B., Talal, T. K., Kim, P., & Lavery, L. A. (2013) · Diabetic Foot & Ankle · doi:10.3402/dfa.v4i0.22081 · Cited by 258
Kalmykov, A., Huang, C., Bliley, J., Shiwarski, D., Tashman, J., Abdullah, A., Rastogi, S. K., Shukla, S., Mataev, E., Feinberg, A. W., et al. (2019) · Science Advances · doi:10.1126/sciadv.aax0729 · Cited by 233
“Currently, electrophysiological studies of cells and tissues are carried out using a variety of techniques, including glass micropipette patch-clamp electrodes (11), voltageand Ca2+-sensitive dyes (12), multielectrode arrays (MEAs) (13), and planar field-effect transistors (FETs) (14).”
BackgroundIon channels and signaling in the pituitary gland
Stojilkovic, S. S., Tabak, J., & Bertram, R. (2010) · Endocrine Reviews · doi:10.1210/er.2010-0005 · Cited by 229
United in Diversity: Mechanosensitive Ion Channels in Plants
Hamilton, E. S., Schlegel, A. M., & Haswell, E. S. (2015) · Annual Review of Plant Biology · doi:10.1146/annurev-arplant-043014-114700 · Cited by 221
Chloride channels in epithelia
Gögelein, H. (1988) · Biochimica et Biophysica Acta (BBA) - Reviews on Biomembranes · doi:10.1016/0304-4157(88)90006-8 · Cited by 211
Track‐Etched Nanopore/Membrane: From Fundamental to Applications
Ma, T., Janot, J., & Balme, S. (2020) · Small Methods · doi:10.1002/smtd.202000366 · Cited by 210
WIMMERS, S., KARL, M., & STRAUSS, O. (2007) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2006.12.002 · Cited by 207
Antibodies and venom peptides: new modalities for ion channels
Wulff, H., Christophersen, P., Colussi, P., Chandy, K. G., & Yarov-Yarovoy, V. (2019) · Nature Reviews Drug Discovery · doi:10.1038/s41573-019-0013-8 · Cited by 182
Sivaramakrishnan, S., & Oliver, D. L. (2001) · The Journal of Neuroscience · doi:10.1523/jneurosci.21-08-02861.2001 · Cited by 179
Mammalian electrophysiology on a microfluidic platform
Ionescu-Zanetti, C., Shaw, R. M., Seo, J., Jan, Y.-N., Jan, L. Y., & Lee, L. P. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503418102 · Cited by 178
Implantable neurotechnologies: a review of micro- and nanoelectrodes for neural recording
Patil, A. C., & Thakor, N. V. (2016) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-015-1430-4 · Cited by 175
“In the late 1970s, Neher and Sakmann introduced the patch clamp recording technique to measure the single ion channel currents [64, 142, 163].”
BackgroundSturgess, N. C., Kozlowski, R. Z., Carrington, C. A., Hales, C. N., & Ashford, M. L. J. (1988) · British Journal of Pharmacology · doi:10.1111/j.1476-5381.1988.tb16551.x · Cited by 169
Calcium and Sodium Channels in Spontaneously Contracting Vascular Muscle Cells
Sturek, M., & Hermsmeyer, K. (1986) · Science · doi:10.1126/science.2425434 · Cited by 166
Properties and regulation of calcium channels in muscle cells
Pelzer, D., Pelzer, S., & McDonald, T. F. (1990) · Reviews of Physiology, Biochemistry and Pharmacology · doi:10.1007/bfb0031019 · Cited by 165
Cardiac cell modelling: Observations from the heart of the cardiac physiome project
Fink, M., Niederer, S. A., Cherry, E. M., Fenton, F. H., Koivumäki, J. T., Seemann, G., Thul, R., Zhang, H., Sachse, F. B., Beard, D., et al. (2011) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2010.03.002 · Cited by 164
“Some examples of applying these techniques to sub-cellular architecture of myocytes are given in Savio-Galimberti et al. (2008), Hayashi et al.”
MethodChen, J., Xue, C., Zhao, Y., Chen, D., Wu, M.-H., & Wang, J. (2015) · International Journal of Molecular Sciences · doi:10.3390/ijms16059804 · Cited by 160
“Patch-clamp devices characterize the activities of cellular ion channels by sucking a portion of cell membrane into a micropipette tip to form a high electrical resistance seal, enabling the quantification of specific membrane capacitance of single cells (an intrinsic size-independent electrical parameter of cells) [1…”
BackgroundSingle odor-sensitive channels in olfactory receptor neurons are also gated by cyclic nucleotides
Firestein, S., Zufall, F., & Shepherd, G. (1991) · The Journal of Neuroscience · doi:10.1523/jneurosci.11-11-03565.1991 · Cited by 159
“Recordings were made using the cell-attached configuration of the patch clamp (Sakmann and Neher, 1984 ) and odor-induced (Firestein and Werblin, 1989; Firestein et al., 1990) macroscopic ionic currents have been recorded in similarappearing cells.”
MethodBoinagrov, D., Pangratz-Fuehrer, S., Goetz, G., & Palanker, D. (2014) · Journal of Neural Engineering · doi:10.1088/1741-2560/11/2/026008 · Cited by 146
“The patch-clamp technique (Sakmann and Neher 1984) was used to record the cell potential of individual RGCs with soma diameters larger than average (>15 μm).”
MethodThree-dimensional cardiac computational modelling: methods, features and applications.
Lopez-Perez, A., Sebastian, R., & Ferrero, J. M. (2015) · BioMedical Engineering OnLine · doi:10.1186/s12938-015-0033-5 · Cited by 151
“Over the past decades, extensive patch-clamp experiments that reveal the dynamic properties of ionic channels [105] have provided data to formulate”
BackgroundDynamics of cortical dendritic membrane potential and spikes in freely behaving rats.
Moore, J. J., Ravassard, P. M., Ho, D., Acharya, L., Kees, A. L., Vuong, C., & Mehta, M. R. (2017) · Science · doi:10.1126/science.aaj1497 · Cited by 110
“Two-photon calcium imaging (21, 26, 39, 40), sharp electrode (2), or patch-clamp techniques (41) can be used to study dendrites in vivo.”
Statistical Kinetics of Macromolecular Dynamics
Shaevitz, J. W., Block, S. M., & Schnitzer, M. J. (2005) · Biophysical Journal · doi:10.1529/biophysj.105.064295 · Cited by 86
“For example, single-channel recordings enable measurements of ionic conductance states with impressive precision ((1) and references therein).”
Nag, O. K., Stewart, M. H., Deschamps, J. R., Susumu, K., Oh, E., Tsytsarev, V., Tang, Q., Efros, A. L., Vaxenburg, R., Black, B. J., et al. (2017) · ACS Nano · doi:10.1021/acsnano.7b00954 · Cited by 80
“single cells.(14) Microelectrode-based techniques are similarly invasive and record membrane potential extracellularly which prohibits single-cell resolution.”
Molecular genetics and imaging technologies for circuit-based neuroanatomy
Arenkiel, B. R., & Ehlers, M. D. (2009) · Nature · doi:10.1038/nature08536 · Cited by 78
Linking hippocampal multiplexed tuning, Hebbian plasticity and navigation
Moore, J. J., Cushman, J. D., Acharya, L., Popeney, B., & Mehta, M. R. (2021) · Nature · doi:10.1038/s41586-021-03989-z · Cited by 69
Methods in Statistical Kinetics
Moffitt, J. R., Chemla, Y. R., & Bustamante, C. (2010) · Methods in Enzymology · doi:10.1016/s0076-6879(10)75010-2 · Cited by 66
Massobrio, G., Massobrio, P., & Martinoia, S. (2008) · Nano Letters · doi:10.1021/nl802341r · Cited by 32
Metadata
- Authors
- Sakmann, B., & Neher, E.
- Venue
- Annual Review of Physiology
- Publisher
- Annual Reviews
- Published
- 1984-10
- Volume
- 46
- Issue
- 1
- Pages
- 455-472
- ISSN
- 0066-4278 (ISSN-L)
- 1545-1585
- OpenAlex
- W2162016003
- Cited by
- 755
- References
- 37
- FWCI
- 4.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.