FOURIER TRANSFORM INFRARED VIBRATIONAL SPECTROSCOPIC IMAGING: Integrating Microscopy and Molecular Recognition
The DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
▪ Abstract The recent development of Fourier transform infrared (FTIR) spectroscopic imaging has enhanced our capability to examine, on a microscopic scale, the spatial distribution of vibrational spectroscopic signatures of materials spanning the physical and biomedical disciplines. Recent activity in this emerging area has concentrated on instrumentation development, theoretical analyses to provide guidelines for imaging practice, novel data processing algorithms, and the introduction of the technique to new fields. To illustrate the impact and promise of this spectroscopic imaging methodology, we present fundamental principles of the technique in the context of FTIR spectroscopy and review new applications in various venues ranging from the physical chemistry of macromolecular systems to the detection of human disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring the Accuracy of Diagnostic Systems
Swets, J. A. (1988) · Science · doi:10.1126/science.3287615 · Cited by 10,058
Mathematical Methods for Physicists
Arfken, G., & Mathews, J. (1972) · American Journal of Physics · doi:10.1119/1.1988084 · Cited by 4,038
Fourier Transform Infrared Spectrometry
Griffiths, P. R., & de Haseth, J. A. (2007) · doi:10.1002/047010631x · Cited by 3,052 · cited 1×
“For a conventional wide-beam single-element detector in an FTIR spectrometer incorporating a Michelson interferometer, the SNR achieved in time, t, is represented by (29)”
MethodHandbook of Vibrational Spectroscopy
(2001) · Wiley eBooks · doi:10.1002/0470027320 · Cited by 2,986
Statistical Pattern Recognition
(2001) · Computational Statistics Handbook with MATLAB · doi:10.1201/9781420035636-10 · Cited by 1,740
Statistical Pattern Recognition
Webb, A. R. (2002) · Wiley eBooks · doi:10.1002/0470854774 · Cited by 1,459
Massart, D. L. (1988) · Cited by 1,347
Near-field probing of vibrational absorption for chemical microscopy
Knoll, B., & Keilmann, F. (1999) · Nature · doi:10.1038/20154 · Cited by 926
Controlled Delivery Systems for Proteins Based on Poly(Lactic/Glycolic Acid) Microspheres
Cohen, S., Yoshioka, T., Lucarelli, M., Hwang, L. H., & Langer, R. (1991) · Pharmaceutical Research · doi:10.1023/a:1015841715384 · Cited by 843
Fourier transform infrared spectrometry
Honigs, D. E. (1986) · TrAC Trends in Analytical Chemistry · doi:10.1016/0165-9936(86)85067-1 · Cited by 799
Cited by
Li, J., Liu, H., & Paul Chen, J. (2018) · Water Research · doi:10.1016/j.watres.2017.12.056 · Cited by 2,314
Microplastic in Aquatic Ecosystems
Ivleva, N. P., Wiesheu, A. C., & Niessner, R. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201606957 · Cited by 943
Methodology Used for the Detection and Identification of Microplastics—A Critical Appraisal
Löder, M. G. J., & Gerdts, G. (2015) · Marine Anthropogenic Litter · doi:10.1007/978-3-319-16510-3_8 · Cited by 796
Fourier transform infrared (FTIR) spectroscopy
Berthomieu, C., & Hienerwadel, R. (2009) · Photosynthesis Research · doi:10.1007/s11120-009-9439-x · Cited by 788
Infrared spectroscopic imaging for histopathologic recognition
Fernandez, D. C., Bhargava, R., Hewitt, S. M., & Levin, I. W. (2005) · Nature Biotechnology · doi:10.1038/nbt1080 · Cited by 592
Self-citationLöder, M. G. J., Kuczera, M., Mintenig, S., Lorenz, C., & Gerdts, G. (2015) · Environmental Chemistry · doi:10.1071/en14205 · Cited by 578
FT-IR imaging of native and tissue-engineered bone and cartilage
Boskey, A., & Pleshko Camacho, N. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.11.043 · Cited by 531
Probing Liquid/Solid Interfaces at the Molecular Level
Zaera, F. (2012) · Chemical Reviews · doi:10.1021/cr2002068 · Cited by 458
Harrison, J. P., Ojeda, J. J., & Romero-González, M. E. (2012) · Science of The Total Environment · doi:10.1016/j.scitotenv.2011.11.078 · Cited by 393
Applications of ATR-FTIR spectroscopic imaging to biomedical samples
Kazarian, S. G., & Chan, K. L. A. (2006) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/j.bbamem.2006.02.011 · Cited by 379
Infrared Imaging and Spectroscopy Beyond the Diffraction Limit
Centrone, A. (2015) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071114-040435 · Cited by 295
Infrared Spectroscopic Imaging: The Next Generation
Bhargava, R. (2012) · Applied Spectroscopy · doi:10.1366/12-06801 · Cited by 280
Self-citationTissue refractive index as marker of disease
Wang, Z., Popescu, G., Tangella, K. V., & Balla, A. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3656732 · Cited by 271
Microplastic particles in the aquatic environment: A systematic review
Ahmed, M. B., Rahman, M. S., Alom, J., Hasan, M. S., Johir, M. A. H., Mondal, M. I. H., Lee, D.-Y., Park, J., Zhou, J. L., & Yoon, M.-H. (2021) · Science of The Total Environment · doi:10.1016/j.scitotenv.2021.145793 · Cited by 263
Environmental fate and impacts of microplastics in aquatic ecosystems: A review
Du, S., Zhu, R., Cai, Y., Xu, N., Yap, P.-S., Zhang, Y., He, Y., & Zhang, Y. (2021) · RSC Advances · doi:10.1039/d1ra00880c · Cited by 261
High throughput methods applied in biomaterial development and discovery
Hook, A. L., Anderson, D. G., Langer, R., Williams, P., Davies, M. C., & Alexander, M. R. (2010) · Biomaterials · doi:10.1016/j.biomaterials.2009.09.037 · Cited by 231
Law, S., Podolskiy, V., & Wasserman, D. (2013) · Nanophotonics · doi:10.1515/nanoph-2012-0027 · Cited by 220
Practical issues of hyperspectral imaging analysis of solid dosage forms
Amigo, J. M. (2010) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-010-3828-z · Cited by 207
Biomedical applications of Raman and infrared spectroscopy to diagnose tissues
Krafft, C., & Sergo, V. (2006) · Journal of Spectroscopy · doi:10.1155/2006/738186 · Cited by 206
“FTIR imaging of microarrays was coupled with statistical pattern recognition techniques in order to demonstrate histopathologic characterization of prostatic tissue and to differentiate benign from malignant prostatic epithelium [3,149,150].”
BackgroundMethodFood chain microplastics contamination and impact on human health: a review
Eze, C. G., Nwankwo, C. E., Dey, S., Sundaramurthy, S., & Okeke, E. S. (2024) · Environmental Chemistry Letters · doi:10.1007/s10311-024-01734-2 · Cited by 186
“To create a chemical image of the sample, thousands of spectra are captured inside the measuring area (Levin and Bhargava 2004).”
Biomarkers for wound healing and their evaluation
Patel, S., Maheshwari, A., & Chandra, A. (2016) · Journal of Wound Care · doi:10.12968/jowc.2016.25.1.46 · Cited by 185
Towards a practical Fourier transform infrared chemical imaging protocol for cancer histopathology
Bhargava, R. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1511-9 · Cited by 184
Self-citationAmenabar, I., Poly, S., Goikoetxea, M., Nuansing, W., Lasch, P., & Hillenbrand, R. (2017) · Nature Communications · doi:10.1038/ncomms14402 · Cited by 180
Extraction and detection methods of microplastics in food and marine systems: A critical review
Sridhar, A., Kannan, D., Kapoor, A., & Prabhakar, S. (2022) · Chemosphere · doi:10.1016/j.chemosphere.2021.131653 · Cited by 178
Rokstad, A. M. A., Lacík, I., de Vos, P., & Strand, B. L. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.07.010 · Cited by 160
“The surface analysis by ATR-FTIR spectroscopy is on a micrometer scale and provides the information on bulk chemistry of materials in a spatially resolved manner [25].”
BackgroundTheory of Midinfrared Absorption Microspectroscopy: I. Homogeneous Samples
Davis, B. J., Carney, P. S., & Bhargava, R. (2010) · Analytical Chemistry · doi:10.1021/ac902067p · Cited by 115
Self-citationShedding new light on lipid functions with CARS and SRS microscopy
Yu, Y., Ramachandran, P. V., & Wang, M. C. (2014) · Biochimica et Biophysica Acta (BBA) - Molecular and Cell Biology of Lipids · doi:10.1016/j.bbalip.2014.02.003 · Cited by 89
“Infrared microscopy has grown rapidly in recent years, but it is limited by low spatial resolution due to long infrared wavelengths, and reduced sensitivity due to non-background-free detection (a detailed account of infrared microscopy is available in reference [14]).”
van Dijk, T., Mayerich, D., Carney, P. S., & Bhargava, R. (2013) · Applied Spectroscopy · doi:10.1366/12-06847 · Cited by 55
Self-citationVibrational spectroscopic mapping and imaging of tissues and cells
Carter, E. A., Tam, K. K., Armstrong, R. S., & Lay, P. A. (2009) · Biophysical Reviews · doi:10.1007/s12551-009-0012-9 · Cited by 41
“The mapping of biological samples with a benchtop globar source is slow because of the relatively weak IR intensity resulting from the use of apertures in the microscope to physically restrict the IR absorption to the sample area of interest (Levin and Bhargava 2005).”
Background
Metadata
- Authors
- Levin, I. W., & Bhargava, R.
- Venue
- Annual Review of Physical Chemistry
- Publisher
- Annual Reviews
- Published
- 2005-05-05
- Volume
- 56
- Issue
- 1
- Pages
- 429-474
- ISSN
- 0066-426X (ISSN-L)
- 1545-1593
- OpenAlex
- W2090511991
- Cited by
- 300
- References
- 53
- FWCI
- 1.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.