Staging Hepatic Fibrosis: Comparison of Gadoxetate Disodium–enhanced and Diffusion-weighted MR Imaging—Preliminary Observations
The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate the utility of hepatocyte-phase gadoxetate disodium-enhanced magnetic resonance (MR) imaging in staging hepatic fibrosis and to compare it with diffusion-weighted imaging. MATERIALS AND METHODS: This retrospective study had institutional review board approval, and the requirement for informed consent was waived. Gadoxetate disodium-enhanced and diffusion-weighted MR images obtained in 114 consecutive patients (70 men, 44 women; age range, 37-91 years) were evaluated. Liver-to-muscle signal intensity (SI) ratio on hepatocyte-phase images (SI(post)), contrast enhancement index calculated as SI(post) /SI(pre), where SI(pre) is liver-to-muscle SI ratio on nonenhanced images, and apparent diffusion coefficient (ADC) of the liver were measured. Necroinflammatory activity grades and hepatic fibrosis stages were histopathologically determined in 99 patients. Multiple regressions of SI(post), contrast enhancement index, ADC, serum albumin concentration, serum total bilirubin level, prothrombin time, and Child-Pugh score were examined to determine correlation with hepatic necroinflammatory activity grades and fibrosis stages. RESULTS: Among the MR, hematologic, and clinical parameters, contrast enhancement index was most strongly correlated with fibrosis stage (r = -0.79, P < .001). Multiple regression analysis showed that the contrast enhancement index, ADC, and prothrombin time were significantly correlated (r(2) = 0.66, P < .05) with fibrosis stage and that the contrast enhancement index and serum total bilirubin level were weakly correlated (r(2) = 0.24, P < .05) with the necroinflammatory activity grade. CONCLUSION: Gadoxetate disodium-enhanced MR imaging is more reliable for staging hepatic fibrosis than are diffusion-weighted MR imaging, hematologic, and clinical parameters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Transection of the oesophagus for bleeding oesophageal varices
Pugh, R. N. H., Murray-Lyon, I. M., Dawson, J. L., Pietroni, M. C., & Williams, R. (1973) · Journal of British Surgery · doi:10.1002/bjs.1800600817 · Cited by 7,941
Sampling error and intraobserver variation in liver biopsy in patients with chronic HCV infection
Regev, A., Berho, M. E., Jeffers, L. J., Milikowski, C., Molina, E. G., Pyrsopoulos, N., Feng, Z.-Z., Reddy, K. R., & Schiff, E. R. (2002) · The American Journal of Gastroenterology · doi:10.1016/s0002-9270(02)04396-4 · Cited by 2,093
Bravo, A. A., Sheth, S. G., & Chopra, S. (2001) · New England Journal of Medicine · doi:10.1056/nejm200102153440706 · Cited by 2,041
Diffusion-Weighted Magnetic Resonance Imaging as a Cancer Biomarker: Consensus and Recommendations
Padhani, A. R., Liu, G., Mu-Koh, D., Chenevert, T. L., Thoeny, H. C., Takahara, T., Dzik-Jurasz, A., Ross, B. D., Van Cauteren, M., Collins, D., et al. (2009) · Neoplasia · doi:10.1593/neo.81328 · Cited by 1,989
Complications following percutaneous liver biopsy
Piccinino, F., Sagnelli, E., Pasquale, G., Giusti, G., Battocchia, A., Bernardi, M., Bertolazzi, R., Bianchi, F. B., Brunelli, E., Budillon, G., et al. (1986) · Journal of Hepatology · doi:10.1016/s0168-8278(86)80075-7 · Cited by 1,202
Diffusion-weighted MR Imaging of the Liver
Taouli, B., & Koh, D.-M. (2010) · Radiology · doi:10.1148/radiol.09090021 · Cited by 810
Evaluation of Liver Fibrosis: A Concise Review
Afdhal, N. H., & Nunes, D. (2004) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2004.30110.x · Cited by 622
Liver Cirrhosis: Intravoxel Incoherent Motion MR Imaging—Pilot Study
Luciani, A., Vignaud, A., Cavet, M., Tran Van Nhieu, J., Mallat, A., Ruel, L., Laurent, A., Deux, J.-F., Brugieres, P., & Rahmouni, A. (2008) · Radiology · doi:10.1148/radiol.2493080080 · Cited by 612
Hamm, B., Staks, T., Mühler, A., Bollow, M., Taupitz, M., Frenzel, T., Wolf, K. J., Weinmann, H. J., & Lange, L. (1995) · Radiology · doi:10.1148/radiology.195.3.7754011 · Cited by 575
Yamada, I., Aung, W., Himeno, Y., Nakagawa, T., & Shibuya, H. (1999) · Radiology · doi:10.1148/radiology.210.3.r99fe17617 · Cited by 519
Liver tumors: comparison of MR imaging with Gd-EOB-DTPA and Gd-DTPA.
Vogl, T. J., Kümmel, S., Hammerstingl, R., Schellenbeck, M., Schumacher, G., Balzer, T., Schwarz, W., Müller, P. K., Bechstein, W. O., Mack, M. G., et al. (1996) · Radiology · doi:10.1148/radiology.200.1.8657946 · Cited by 453
MR Elastography of the Liver: Preliminary Results
Rouvière, O., Yin, M., Dresner, M. A., Rossman, P. J., Burgart, L. J., Fidler, J. L., & Ehman, R. L. (2006) · Radiology · doi:10.1148/radiol.2402050606 · Cited by 447
Huppertz, A., Balzer, T., Blakeborough, A., Breuer, J., Giovagnoni, A., Heinz-Peer, G., Laniado, M., Manfredi, R. M., Mathieu, D. G., Mueller, D., et al. (2004) · Radiology · doi:10.1148/radiol.2301020269 · Cited by 396
Preclinical evaluation of Gd-EOB-DTPA as a contrast agent in MR imaging of the hepatobiliary system.
Schuhmann-Giampieri, G., Schmitt-Willich, H., Press, W. R., Negishi, C., Weinmann, H. J., & Speck, U. (1992) · Radiology · doi:10.1148/radiology.183.1.1549695 · Cited by 380
Huppertz, A., Haraida, S., Kraus, A., Zech, C. J., Scheidler, J., Breuer, J., Helmberger, T. K., & Reiser, M. F. (2005) · Radiology · doi:10.1148/radiol.2342040278 · Cited by 370
Huwart, L., Sempoux, C., Salameh, N., Jamart, J., Annet, L., Sinkus, R., Peeters, F., ter Beek, L. C., Horsmans, Y., & Van Beers, B. E. (2007) · Radiology · doi:10.1148/radiol.2452061673 · Cited by 365
Phase II clinical evaluation of Gd-EOB-DTPA: dose, safety aspects, and pulse sequence.
Reimer, P., Rummeny, E. J., Shamsi, K., Balzer, T., Daldrup, H. E., Tombach, B., Hesse, T., Berns, T., & Peters, P. E. (1996) · Radiology · doi:10.1148/radiology.199.1.8633143 · Cited by 309
Reimer, P., Schneider, G., & Schima, W. (2004) · European Radiology · doi:10.1007/s00330-004-2236-1 · Cited by 287
Diffusion-weighted magnetic resonance imaging for the assessment of fibrosis in chronic hepatitis C
Lewin, M., Poujol-Robert, A., Boëlle, P.-Y., Wendum, D., Lasnier, E., Viallon, M., Guéchot, J., Hoeffel, C., Arrivé, L., Tubiana, J.-M., et al. (2007) · Hepatology · doi:10.1002/hep.21747 · Cited by 265
A new lipophilic gadolinium chelate as a tissue‐specific contrast medium for MRI
Weinmann, H. ‐., Schuhmann‐Giampieri, G., Schmitt‐Willich, H., Vogler, H., Frenzel, T., & Gries, H. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910220214 · Cited by 237
Zech, C. J., Grazioli, L., Breuer, J., Reiser, M. F., & Schoenberg, S. O. (2008) · Investigative Radiology · doi:10.1097/rli.0b013e3181705cd1 · Cited by 227
Advanced Liver Fibrosis: Diagnosis with 3D Whole-Liver Perfusion MR Imaging—Initial Experience
Hagiwara, M., Rusinek, H., Lee, V. S., Losada, M., Bannan, M. A., Krinsky, G. A., & Taouli, B. (2008) · Radiology · doi:10.1148/radiol.2463070077 · Cited by 227
Bluemke, D. A., Sahani, D., Amendola, M., Balzer, T., Breuer, J., Brown, J. J., Casalino, D. D., Davis, P. L., Francis, I. R., Krinsky, G., et al. (2005) · Radiology · doi:10.1148/radiol.2371031842 · Cited by 223
Koinuma, M., Ohashi, I., Hanafusa, K., & Shibuya, H. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20344 · Cited by 218
Role of liver biopsy in management of chronic hepatitis C: A systematic review
Gebo, K. A., Herlong, F. H., Torbenson, M. S., Jenckes, M. W., Chander, G., Ghanem, K. G., El-Kamary, S. S., Sulkowski, M., & Bass, E. B. (2002) · Hepatology · doi:10.1053/jhep.2002.36989 · Cited by 218
Kim, H., Taksali, S. E., Dufour, S., Befroy, D., Goodman, T. R., Petersen, K. F., Shulman, G. I., Caprio, S., & Constable, R. T. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21561 · Cited by 206
Value of Diffusion-Weighted MRI for Assessing Liver Fibrosis and Cirrhosis
Sandrasegaran, K., Akisik, F. M., Lin, C., Tahir, B., Rajan, J., Saxena, R., & Aisen, A. M. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.2436 · Cited by 192
Assessment of diffusion‐weighted MR imaging in liver fibrosis
Annet, L., Peeters, F., Abarca‐Quinones, J., Leclercq, I. A., Moulin, P., & BEERS, B. E. V. (2006) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20771 · Cited by 153
Saito, K., Kotake, F., Ito, N., Ozuki, T., Mikami, R., Abe, K., & SHIMAZAKI, Y. (2005) · Magnetic Resonance in Medical Sciences · doi:10.2463/mrms.4.1 · Cited by 150
Quantitative Evaluation of Liver Function with MRI Using Gd-EOB-DTPA
Ryeom, H. K., Kim, S., Kim, J.-Y., Kim, H.-J., Lee, J. M., Chang, Y., Kim, Y., & Kang, D.-S. (2004) · Korean Journal of Radiology · doi:10.3348/kjr.2004.5.4.231 · Cited by 146
Frericks, B. B., Loddenkemper, C., Huppertz, A., Valdeig, S., Stroux, A., Seja, M., Wolf, K.-J., & Albrecht, T. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.1946 · Cited by 140
Buti, M., Miguel, R. S., Brosa, M., Hita, J. M. C., Medina, M., Casado, M. Á., Fosbrook, L., & Esteban, R. (2005) · Journal of Hepatology · doi:10.1016/j.jhep.2004.12.031 · Cited by 108
Motosugi, U., Ichikawa, T., Tominaga, L., Sou, H., Sano, K., Ichikawa, S., & Araki, T. (2009) · European Radiology · doi:10.1007/s00330-009-1467-6 · Cited by 94
Tsuda, N., Okada, M., & Murakami, T. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2008.09.036 · Cited by 64
Ni, Y., Marchal, G., Lukito, G., Yu, J., Mühler, A., & Baert, A. L. (1994) · Radiology · doi:10.1148/radiology.190.3.8115623 · Cited by 48
Metadata
- Authors
- Watanabe, H., Kanematsu, M., Goshima, S., Kondo, H., Onozuka, M., Moriyama, N., & Bae, K. T.
- Venue
- Radiology
- Published
- 2011-04
- Volume
- 259
- Issue
- 1
- Pages
- 142-150
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2056932673
- Cited by
- 189
- References
- 35
- FWCI
- 14.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.