The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Comparison of Digital Mammography Alone and Digital Mammography Plus Tomosynthesis in a Population-based Screening Program
Abstract
PURPOSE: To assess cancer detection rates, false-positive rates before arbitration, positive predictive values for women recalled after arbitration, and the type of cancers detected with use of digital mammography alone and combined with tomosynthesis in a large prospective screening trial. MATERIALS AND METHODS: A prospective, reader- and modality-balanced screening study of participants undergoing combined mammography plus tomosynthesis, the results of which were read independently by four different radiologists, is under way. The study was approved by a regional ethics committee, and all participants provided written informed consent. The authors performed a preplanned interim analysis of results from 12,631 examinations interpreted by using mammography alone and mammography plus tomosynthesis from November 22, 2010, to December 31, 2011. Analyses were based on marginal log-linear models for binary data, accounting for correlated interpretations and adjusting for reader-specific performance levels by using a two-sided significance level of .0294. RESULTS: Detection rates, including those for invasive and in situ cancers, were 6.1 per 1000 examinations for mammography alone and 8.0 per 1000 examinations for mammography plus tomosynthesis (27% increase, adjusted for reader; P = .001). False-positive rates before arbitration were 61.1 per 1000 examinations with mammography alone and 53.1 per 1000 examinations with mammography plus tomosynthesis (15% decrease, adjusted for reader; P < .001). After arbitration, positive predictive values for recalled patients with cancers verified later were comparable (29.1% and 28.5%, respectively, with mammography alone and mammography plus tomosynthesis; P = .72). Twenty-five additional invasive cancers were detected with mammography plus tomosynthesis (40% increase, adjusted for reader; P < .001). The mean interpretation time was 45 seconds for mammography alone and 91 seconds for mammography plus tomosynthesis (P < .001). CONCLUSION: The use of mammography plus tomosynthesis in a screening environment resulted in a significantly higher cancer detection rate and enabled the detection of more invasive cancers. Clinical trial registration no. NCT01248546.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Screening for Lung Cancer: U.S. Preventive Services Task Force Recommendation Statement
Moyer, V. A., & on behalf of the U.S. Preventive Services Task Force* (2014) · Annals of Internal Medicine · doi:10.7326/m13-2771 · Cited by 2,632
Group sequential methods in the design and analysis of clinical trials
POCOCK, S. J. (1977) · Biometrika · doi:10.1093/biomet/64.2.191 · Cited by 1,831
Screening for Breast Cancer: U.S. Preventive Services Task Force Recommendation Statement
U.S. Preventive Services Task Force* (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-10-200911170-00008 · Cited by 1,686
European guidelines for quality assurance in breast cancer screening and diagnosis
Amendoeira, I., Perry, N., Broeders, M. J. M., de Wolf, C., Törnberg, S., Holland, R. D., & von Karsa, L. (2013) · Zurich Open Repository and Archive (University of Zurich) · doi:10.2772/13196 · Cited by 1,556
Berg, W. A. (2008) · JAMA · doi:10.1001/jama.299.18.2151 · Cited by 1,526
Perry, N., Broeders, M., de Wolf, C., Törnberg, S., Holland, R., & von Karsa, L. (2008) · Annals of Oncology · doi:10.1093/annonc/mdm481 · Cited by 1,020
Tabár, L., Vitak, B., Chen, T. H.-H., Yen, A. M.-F., Cohen, A., Tot, T., Chiu, S. Y.-H., Chen, S. L.-S., Fann, J. C.-Y., Rosell, J., et al. (2011) · Radiology · doi:10.1148/radiol.11110469 · Cited by 791
Digital tomosynthesis in breast imaging.
Niklason, L. T., Christian, B. T., Niklason, L. E., Kopans, D. B., Castleberry, D. E., Opsahl-Ong, B. H., Landberg, C. E., Slanetz, P. J., Giardino, A. A., Moore, R., et al. (1997) · Radiology · doi:10.1148/radiology.205.2.9356620 · Cited by 763
Self-citationDigital Breast Tomosynthesis: Observer Performance Study
Gur, D., Abrams, G. S., Chough, D. M., Ganott, M. A., Hakim, C. M., Perrin, R. L., Rathfon, G. Y., Sumkin, J. H., Zuley, M. L., & Bandos, A. I. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.08.2031 · Cited by 363
Self-citationAndersson, I., Ikeda, D. M., Zackrisson, S., Ruschin, M., Svahn, T., Timberg, P., & Tingberg, A. (2008) · European Radiology · doi:10.1007/s00330-008-1076-9 · Cited by 343
Digital breast tomosynthesis versus digital mammography: a clinical performance study
Gennaro, G., Toledano, A., di Maggio, C., Baldan, E., Bezzon, E., La Grassa, M., Pescarini, L., Polico, I., Proietti, A., Toffoli, A., et al. (2010) · European Radiology · doi:10.1007/s00330-009-1699-5 · Cited by 257
Kalager, M., Adami, H.-O., Bretthauer, M., & Tamimi, R. M. (2012) · Annals of Internal Medicine · doi:10.7326/0003-4819-156-7-201204030-00005 · Cited by 243
Skaane, P., & Skjennald, A. (2004) · Radiology · doi:10.1148/radiol.2321031624 · Cited by 236
Self-citationSkaane, P., Young, K., & Skjennald, A. (2003) · Radiology · doi:10.1148/radiol.2293021171 · Cited by 221
Self-citationVisual Detection and Localization of Radiographic Images
Starr, S. J., Metz, C. E., Lusted, L. B., & Goodenough, D. J. (1975) · Radiology · doi:10.1148/116.3.533 · Cited by 208
Wallis, M. G., Moa, E., Zanca, F., Leifland, K., & Danielsson, M. (2012) · Radiology · doi:10.1148/radiol.11103514 · Cited by 187
Interpreting Overdiagnosis Estimates in Population-based Mammography Screening
de Gelder, R., Heijnsdijk, E. A. M., van Ravesteyn, N. T., Fracheboud, J., Draisma, G., & de Koning, H. J. (2011) · Epidemiologic Reviews · doi:10.1093/epirev/mxr009 · Cited by 185
The US Food and Drug Administration perspective on cancer biomarker development
Gutman, S., & Kessler, L. G. (2006) · Nature Reviews Cancer · doi:10.1038/nrc1911 · Cited by 176
Schatzkin, A. G., Connor, R., Taylor, P. R., & Bunnag, B. (1987) · American Journal of Epidemiology · doi:10.1093/oxfordjournals.aje.a114580 · Cited by 112
Effect of Computer-aided Detection for CT Colonography in a Multireader, Multicase Trial
Dachman, A. H., Obuchowski, N. A., Hoffmeister, J. W., Hinshaw, J. L., Frew, M. I., Winter, T. C., Uitert, R. L. V., Periaswamy, S., Summers, R. M., & Hillman, B. J. (2010) · Radiology · doi:10.1148/radiol.10091890 · Cited by 99
The Use of Breast Imaging to Screen Women at High Risk for Cancer
Sickles, E. A. (2010) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2010.06.012 · Cited by 98
Mammographic Screening and “Overdiagnosis”
Kopans, D. B., Smith, R. A., & Duffy, S. W. (2011) · Radiology · doi:10.1148/radiol.11110716 · Cited by 95
Comparing disease screening tests when true disease status is ascertained only for screen positives
Pepe, M. S., & Alonzo, T. A. (2001) · Biostatistics · doi:10.1093/biostatistics/2.3.249 · Cited by 94
Guittet, L., Bouvier, V., Mariotte, N., Vallée, J.-P., Levillain, R., Tichet, J., & Launoy, G. D. (2009) · British Journal of Cancer · doi:10.1038/sj.bjc.6604996 · Cited by 73
Cited by
Screening for breast cancer: U.S. Preventive Services Task Force recommendation statement
Siu, A. L., & on behalf of the U.S. Preventive Services Task Force (2016) · Annals of Internal Medicine · doi:10.7326/m15-2886 · Cited by 2,094
Screening for Breast Cancer: U.S. Preventive Services Task Force Recommendation Statement
U.S. Preventive Services Task Force* (2009) · Annals of Internal Medicine · doi:10.7326/0003-4819-151-10-200911170-00008 · Cited by 1,686
Daly, M. B., Pal, T., Berry, M. P., Buys, S. S., Dickson, P., Domchek, S. M., Elkhanany, A., Friedman, S., Goggins, M., Hutton, M. L., et al. (2021) · Journal of the National Comprehensive Cancer Network · doi:10.6004/jnccn.2021.0001 · Cited by 1,112
Kumar, Y., Koul, A., Singla, R., & Ijaz, M. F. (2023) · Journal of Ambient Intelligence and Humanized Computing · doi:10.1007/s12652-021-03612-z · Cited by 1,040
RetractedBreast Cancer Screening Using Tomosynthesis in Combination With Digital Mammography
Friedewald, S. M., Rafferty, E. A., Rose, S. L., Durand, M. A., Plecha, D. M., Greenberg, J. S., Hayes, M. K., Copit, D. S., Carlson, K. L., Cink, T. M., et al. (2014) · JAMA · doi:10.1001/jama.2014.6095 · Cited by 851
Metadata
- Authors
- Skaane, P., Bandos, A. I., Gullien, R., Eben, E. B., Ekseth, U., Haakenaasen, U., Izadi, M., Jebsen, I. N., Jahr, G., Krager, M., Niklason, L. T., Hofvind, S., & Gur, D.
- Venue
- Radiology
- Published
- 2013-04
- Volume
- 267
- Issue
- 1
- Pages
- 47-56
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2111066681
- Cited by
- 1,012
- References
- 24
- FWCI
- 90.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.