Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical Trial
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate the safety and effectiveness of the Pipeline Embolization Device (PED; ev3/Covidien, Irvine, Calif) in the treatment of complex intracranial aneurysms. MATERIALS AND METHODS: The Pipeline for Uncoilable or Failed Aneurysms is a multicenter, prospective, interventional, single-arm trial of PED for the treatment of uncoilable or failed aneurysms of the internal carotid artery. Institutional review board approval of the HIPAA-compliant study protocol was obtained from each center. After providing informed consent, 108 patients with recently unruptured large and giant wide-necked aneurysms were enrolled in the study. The primary effectiveness endpoint was angiographic evaluation that demonstrated complete aneurysm occlusion and absence of major stenosis at 180 days. The primary safety endpoint was occurrence of major ipsilateral stroke or neurologic death at 180 days. RESULTS: PED placement was technically successful in 107 of 108 patients (99.1%). Mean aneurysm size was 18.2 mm; 22 aneurysms (20.4%) were giant (>25 mm). Of the 106 aneurysms, 78 met the study's primary effectiveness endpoint (73.6%; 95% posterior probability interval: 64.4%-81.0%). Six of the 107 patients in the safety cohort experienced a major ipsilateral stroke or neurologic death (5.6%; 95% posterior probability interval: 2.6%-11.7%). CONCLUSION: PED offers a reasonably safe and effective treatment of large or giant intracranial internal carotid artery aneurysms, demonstrated by high rates of complete aneurysm occlusion and low rates of adverse neurologic events; even in aneurysms failing previous alternative treatments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wiebers, D. O. (2003) · The Lancet · doi:10.1016/s0140-6736(03)13860-3 · Cited by 3,905
Molyneux, A. J., Kerr, R. S., Yu, L.-M., Clarke, M., Sneade, M., Yarnold, J. A., & Sandercock, P. (2005) · The Lancet · doi:10.1016/s0140-6736(05)67214-5 · Cited by 2,886
Raymond, J., Guilbert, F., Weill, A., Georganos, S. A., Juravsky, L., Lambert, A., Lamoureux, J., Chagnon, M., & Roy, D. (2003) · Stroke · doi:10.1161/01.str.0000073841.88563.e9 · Cited by 1,496
Molyneux, A., & Kerr, R. (2002) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1053/jscd.2002.130390 · Cited by 957
A standardized method for measuring intracranial arterial stenosis.
Samuels, O. B., Joseph, G., Lynn, M., Smith, H. A., & Chimowitz, M. I. (2000) · PubMed Central · Cited by 951
Brisman, J. L., Song, J. K., & Newell, D. W. (2006) · New England Journal of Medicine · doi:10.1056/nejmra052760 · Cited by 896
The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms Trial
Nelson, P. K., Lylyk, P., Szikora, I., Wetzel, S. G., Wanke, I., & Fiorella, D. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2421 · Cited by 843
Self-citationGuglielmi Detachable Coil embolization of cerebral aneurysms: 11 years' experience
Murayama, Y., Nien, Y. L., Duckwiler, G., Gobin, Y. P., Jahan, R., Frazee, J., Martin, N., & Viñuela, F. (2003) · Journal of Neurosurgery · doi:10.3171/jns.2003.98.5.0959 · Cited by 810
Piotin, M., Blanc, R., Spelle, L., Mounayer, C., Piantino, R., Schmidt, P. J., & Moret, J. (2010) · Stroke · doi:10.1161/strokeaha.109.558114 · Cited by 644
Campi, A., Ramzi, N., Molyneux, A. J., Summers, P. E., Kerr, R. S. C., Sneade, M., Yarnold, J. A., Rischmiller, J., & Byrne, J. V. (2007) · Stroke · doi:10.1161/strokeaha.106.466987 · Cited by 553
Kulcsár, Z., Houdart, E., Bonafé, A., Parker, G., Millar, J., Goddard, A. J. P., Renowden, S., Gál, G., Turowski, B., Mitchell, K., et al. (2011) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2370 · Cited by 521
Fischer, S., Vajda, Z., Aguilar Perez, M., Schmid, E., Hopf, N., Bäzner, H., & Henkes, H. (2012) · Neuroradiology · doi:10.1007/s00234-011-0948-x · Cited by 393
Stent-Supported Aneurysm Coiling: A Literature Survey of Treatment and Follow-Up
Shapiro, M., Becske, T., Sahlein, D., Babb, J., & Nelson, P. K. (2012) · American Journal of Neuroradiology · doi:10.3174/ajnr.a2719 · Cited by 244
Self-citationSluzewski, M., Menovsky, T., van Rooij, W. J., & Wijnalda, D. (2003) · PubMed · Cited by 225
Pierot, L., Leclerc, X., Bonafé, A., & Bracard, S. (2007) · American Journal of Neuroradiology · doi:10.3174/ajnr.a0738 · Cited by 47
Cited by
Thompson, B. G., Brown, R. D., Amin-Hanjani, S., Broderick, J. P., Cockroft, K. M., Connolly, E. S., Duckwiler, G. R., Harris, C. C., Howard, V. J., Johnston, S. C. (., et al. (2015) · Stroke · doi:10.1161/str.0000000000000070 · Cited by 1,046
Becske, T., Brinjikji, W., Potts, M. B., Kallmes, D. F., Shapiro, M., Moran, C. J., Levy, E. I., McDougall, C. G., Szikora, I., Lanzino, G., et al. (2017) · Neurosurgery · doi:10.1093/neuros/nyw014 · Cited by 447
Self-citationHanel, R. A., Kallmes, D. F., Lopes, D. K., Nelson, P. K., Siddiqui, A., Jabbour, P., Pereira, V. M., Szikora István, I., Zaidat, O. O., Bettegowda, C., et al. (2020) · Journal of NeuroInterventional Surgery · doi:10.1136/neurintsurg-2019-015091 · Cited by 313
Self-citationAneurysmal Subarachnoid Hemorrhage
D’Souza, S. (2015) · Journal of Neurosurgical Anesthesiology · doi:10.1097/ana.0000000000000130 · Cited by 294
Endovascular Treatment of Intracranial Aneurysms: Current Status
Pierot, L., & Wakhloo, A. K. (2013) · Stroke · doi:10.1161/strokeaha.113.000733 · Cited by 289
Metadata
- Authors
- Becske, T., Kallmes, D. F., Saatci, I., McDougall, C. G., Szikora, I., Lanzino, G., Moran, C. J., Woo, H. H., Lopes, D. K., Berez, A. L., Cher, D. J., Siddiqui, A. H., Levy, E. I., Albuquerque, F. C., Fiorella, D. J., Berentei, Z., Marősfoi, M., Cekirge, S. H., & Nelson, P. K.
- Venue
- Radiology
- Published
- 2013-06
- Volume
- 267
- Issue
- 3
- Pages
- 858-868
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2124360594
- Cited by
- 1,108
- References
- 15
- FWCI
- 55.66
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.