Clinical Proton MR Spectroscopy in Central Nervous System Disorders
Open accessThe DOI matches its Crossref record; 131 of the 131 references it cites were found in a registry or an index.
Abstract
A large body of published work shows that proton (hydrogen 1 [(1)H]) magnetic resonance (MR) spectroscopy has evolved from a research tool into a clinical neuroimaging modality. Herein, the authors present a summary of brain disorders in which MR spectroscopy has an impact on patient management, together with a critical consideration of common data acquisition and processing procedures. The article documents the impact of (1)H MR spectroscopy in the clinical evaluation of disorders of the central nervous system. The clinical usefulness of (1)H MR spectroscopy has been established for brain neoplasms, neonatal and pediatric disorders (hypoxia-ischemia, inherited metabolic diseases, and traumatic brain injury), demyelinating disorders, and infectious brain lesions. The growing list of disorders for which (1)H MR spectroscopy may contribute to patient management extends to neurodegenerative diseases, epilepsy, and stroke. To facilitate expanded clinical acceptance and standardization of MR spectroscopy methodology, guidelines are provided for data acquisition and analysis, quality assessment, and interpretation. Finally, the authors offer recommendations to expedite the use of robust MR spectroscopy methodology in the clinical setting, including incorporation of technical advances on clinical units.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Early Identification of Refractory Epilepsy
Kwan, P., & Brodie, M. J. (2000) · New England Journal of Medicine · doi:10.1056/nejm200002033420503 · Cited by 5,204
Moderate Hypothermia to Treat Perinatal Asphyxial Encephalopathy
Azzopardi, D. V., Strohm, B., Edwards, A. D., Dyet, L., Halliday, H. L., Juszczak, E., Kapellou, O., Levene, M., Marlow, N., Porter, E., et al. (2009) · New England Journal of Medicine · doi:10.1056/nejmoa0900854 · Cited by 1,710
Proton NMR chemical shifts and coupling constants for brain metabolites
Govindaraju, V., Young, K., & Maudsley, A. A. (2000) · NMR in Biomedicine · doi:10.1002/1099-1492(200005)13:3<129::aid-nbm619>3.0.co;2-v · Cited by 1,689
Self-citationAutomatic quantitation of localized in vivo1H spectra with LCModel
Provencher, S. W. (2001) · NMR in Biomedicine · doi:10.1002/nbm.698 · Cited by 1,634
Siesjö, B. K. (1978) · Medical Entomology and Zoology · Cited by 1,437
The Efficacy of Diagnostic Imaging
Fryback, D. G., & Thornbury, J. R. (1991) · Medical Decision Making · doi:10.1177/0272989x9101100203 · Cited by 1,291
Law, M., Yang, S., Wang, H., Babb, J. S., Johnson, G., Cha, S., Knopp, E. A., & Zagzag, D. (2003) · PubMed Central · Cited by 1,084
2-hydroxyglutarate detection by magnetic resonance spectroscopy in IDH-mutated patients with gliomas
Choi, C., Ganji, S. K., DeBerardinis, R. J., Hatanpaa, K. J., Rakheja, D., Kovacs, Z., Yang, X.-L., Mashimo, T., Raisanen, J. M., Marin-Valencia, I., et al. (2012) · Nature Medicine · doi:10.1038/nm.2682 · Cited by 839
Localized proton spectroscopy using stimulated echoes
Frahm, J., Merboldt, K.-D., & Hänicke, W. (1987) · Journal of Magnetic Resonance (1969) · doi:10.1016/0022-2364(87)90154-5 · Cited by 826
Self-citationA review of chemical issues in 1H NMR spectroscopy: N‐acetyl‐l‐aspartate, creatine and choline
Miller, B. L. (1991) · NMR in Biomedicine · doi:10.1002/nbm.1940040203 · Cited by 654
Cited by
Wen, P. Y., Weller, M., Lee, E. Q., Alexander, B. M., Barnholtz-Sloan, J. S., Barthel, F. P., Batchelor, T. T., Bindra, R. S., Chang, S. M., Chiocca, E. A., et al. (2020) · Neuro-Oncology · doi:10.1093/neuonc/noaa106 · Cited by 1,168
Methodological consensus on clinical proton MRS of the brain: Review and recommendations
Wilson, M., Andronesi, O., Barker, P. B., Bartha, R., Bizzi, A., Bolan, P. J., Brindle, K. M., Choi, I., Cudalbu, C., Dydak, U., et al. (2019) · Magnetic Resonance in Medicine · doi:10.1002/mrm.27742 · Cited by 470
Self-citationDeuterium metabolic imaging (DMI) for MRI-based 3D mapping of metabolism in vivo
De Feyter, H. M., Behar, K. L., Corbin, Z. A., Fulbright, R. K., Brown, P. B., McIntyre, S., Nixon, T. W., Rothman, D. L., & de Graaf, R. A. (2018) · Science Advances · doi:10.1126/sciadv.aat7314 · Cited by 376
Lin, A., Andronesi, O., Bogner, W., Choi, I., Coello, E., Cudalbu, C., Juchem, C., Kemp, G. J., Kreis, R., Krššák, M., et al. (2021) · NMR in Biomedicine · doi:10.1002/nbm.4484 · Cited by 334
Self-citationThe trouble with quality filtering based on relative Cramér‐Rao lower bounds
Kreis, R. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25568 · Cited by 261
Self-citationÖz, G., Deelchand, D. K., Wijnen, J. P., Mlynárik, V., Xin, L., Mekle, R., Noeske, R., Scheenen, T. W. J., Tkáč, I., & the Experts' Working Group on Advanced Single Voxel H MRS (2021) · NMR in Biomedicine · doi:10.1002/nbm.4236 · Cited by 189
Self-citationColes, L. D., Tuite, P. J., Öz, G., Mishra, U. R., Kartha, R. V., Sullivan, K. M., Cloyd, J. C., & Terpstra, M. (2018) · The Journal of Clinical Pharmacology · doi:10.1002/jcph.1008 · Cited by 170
Self-citationHypothalamic Inflammation in Human Obesity Is Mediated by Environmental and Genetic Factors
Kreutzer, C., Peters, S., Schulte, D. M., Fangmann, D., Türk, K., Wolff, S., van Eimeren, T., Ahrens, M., Beckmann, J., Schafmayer, C., et al. (2017) · Diabetes · doi:10.2337/db17-0067 · Cited by 160
Friedrich, J., Kordasiewicz, H. B., O’Callaghan, B., Handler, H. P., Wagener, C., Duvick, L., Swayze, E. E., Rainwater, O., Hofstra, B., Benneyworth, M., et al. (2018) · JCI Insight · doi:10.1172/jci.insight.123193 · Cited by 121
Self-citationMatura, S., Fleckenstein, J., Deichmann, R., Engeroff, T., Füzéki, E., Hattingen, E., Hellweg, R., Lienerth, B., Pilatus, U., Schwarz, S., et al. (2017) · Translational Psychiatry · doi:10.1038/tp.2017.135 · Cited by 97
Duan, C., Cosgrove, J., & Deligiannidis, K. M. (2017) · Current Psychiatry Reports · doi:10.1007/s11920-017-0824-4 · Cited by 59
Genovese, G., Palombo, M., Santin, M. D., Valette, J., Ligneul, C., Aigrot, M., Abdoulkader, N., Langui, D., Millecamps, A., Baron‐Van Evercooren, A., et al. (2021) · NMR in Biomedicine · doi:10.1002/nbm.4480 · Cited by 31
Imaging cancer metabolism using magnetic resonance
Brindle, K. M. (2024) · npj Imaging · doi:10.1038/s44303-023-00004-0 · Cited by 22
Self-citationProspects for NMR spectral prediction on fault-tolerant quantum computers
Elenewski, J. E., Camara, C. M., & Kalev, A. (2026) · Physical Review Research · doi:10.1103/km66-ltpl · Cited by 3
Metadata
- Authors
- Öz, G., Alger, J. R., Barker, P. B., Bartha, R., Bizzi, A., Boesch, C., Bolan, P. J., Brindle, K. M., Cudalbu, C., Dinçer, A., Dydak, U., Emir, U. E., Frahm, J., González, R. G., Gruber, S., Gruetter, R., Gupta, R. K., Heerschap, A., Henning, A., Hetherington, H. P., Howe, F. A., Hüppi, P. S., Hurd, R. E., Kantarci, K., Klomp, D. W. J., Kreis, R., Kruiskamp, M. J., Leach, M. O., Lin, A. P., Luijten, P. R., Marjańska, M., Maudsley, A. A., Meyerhoff, D. J., Mountford, C. E., Nelson, S. J., Pamir, M. N., Pan, J. W., Peet, A. C., Poptani, H., Posse, S., Pouwels, P. J. W., Ratai, E.-M., Ross, B. D., Scheenen, T. W. J., Schuster, C., Smith, I. C. P., Soher, B. J., Tkáč, I., Vigneron, D. B., Kauppinen, R. A., & For the MRS Consensus Group
- Venue
- Radiology
- Published
- 2014-03
- Volume
- 270
- Issue
- 3
- Pages
- 658-679
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2099292814
- Cited by
- 660
- References
- 131
- FWCI
- 38.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.