CoChat

Multimaterial Decomposition Algorithm for the Quantification of Liver Fat Content by Using Fast-Kilovolt-Peak Switching Dual-Energy CT: Clinical Evaluation

Hyodo, Tomoko, Yada, Norihisa, Hori, Masatoshi, Maenishi, Osamu, Lamb, Peter, Sasaki, Kosuke, Onoda, Minori, Kudo, Masatoshi, Mochizuki, Teruhito, Murakami, Takamichi · 2017 · Radiology
Cited by 103

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Purpose To assess the clinical accuracy and reproducibility of liver fat quantification with the multimaterial decomposition (MMD) algorithm, comparing the performance of MMD with that of magnetic resonance (MR) spectroscopy by using liver biopsy as the reference standard. Materials and Methods This prospective study was approved by the institutional ethics committee, and patients provided written informed consent. Thirty-three patients suspected of having hepatic steatosis underwent non—contrast material–enhanced and triple-phase dynamic contrast-enhanced dual-energy computed tomography (CT) (80 and 140 kVp) and single-voxel proton MR spectroscopy within 30 days before liver biopsy. Percentage fat volume fraction (FVF) images were generated by using the MMD algorithm on dual-energy CT data to measure hepatic fat content. FVFs determined by using dual-energy CT and percentage fat fractions (FFs) determined by using MR spectroscopy were compared with histologic steatosis grade (0–3, as defined by the nonalcoholic fatty liver disease activity score system) by using Jonckheere-Terpstra trend tests and were compared with each other by using Bland-Altman analysis. Real non–contrast-enhanced FVFs were compared with triple-phase contrast-enhanced FVFs to determine the reproducibility of MMD by using Bland-Altman analyses. Results Both dual-energy CT FVF and MR spectroscopy FF increased with increasing histologic steatosis grade (trend test, P < .001 for each). The Bland-Altman plot of dual-energy CT FVF and MR spectroscopy FF revealed a proportional bias, as indicated by the significant positive slope of the line regressing the difference on the average (P < .001). The 95% limits of agreement for the differences between real non–contrast-enhanced and contrast-enhanced FVFs were not greater than about 2%. Conclusion The MMD algorithm quantifying hepatic fat in dual-energy CT images is accurate and reproducible across imaging phases. © RSNA, 2017 Online supplemental material is available for this article.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiol.2017160130

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 103

Metadata

Authors
Hyodo, T., Yada, N., Hori, M., Maenishi, O., Lamb, P., Sasaki, K., Onoda, M., Kudo, M., Mochizuki, T., & Murakami, T.
Venue
Radiology
Published
2017-04
Volume
283
Issue
1
Pages
108-118
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2517964302
Cited by
103
References
6
FWCI
6.12
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.