The DOI matches its Crossref record; 87 of the 87 references it cites were found in a registry or an index.
Linearity, Bias, and Precision of Hepatic Proton Density Fat Fraction Measurements by Using MR Imaging: A Meta-Analysis
Open accessAbstract
Purpose To determine the linearity, bias, and precision of hepatic proton density fat fraction (PDFF) measurements by using magnetic resonance (MR) imaging across different field strengths, imager manufacturers, and reconstruction methods. Materials and Methods This meta-analysis was performed in accordance with Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines. A systematic literature search identified studies that evaluated the linearity and/or bias of hepatic PDFF measurements by using MR imaging (hereafter, MR imaging–PDFF) against PDFF measurements by using colocalized MR spectroscopy (hereafter, MR spectroscopy-PDFF) or the precision of MR imaging–PDFF. The quality of each study was evaluated by using the Quality Assessment of Studies of Diagnostic Accuracy 2 tool. De-identified original data sets from the selected studies were pooled. Linearity was evaluated by using linear regression between MR imaging–PDFF and MR spectroscopy-PDFF measurements. Bias, defined as the mean difference between MR imaging–PDFF and MR spectroscopy-PDFF measurements, was evaluated by using Bland-Altman analysis. Precision, defined as the agreement between repeated MR imaging–PDFF measurements, was evaluated by using a linear mixed-effects model, with field strength, imager manufacturer, reconstruction method, and region of interest as random effects. Results Twenty-three studies (1679 participants) were selected for linearity and bias analyses and 11 studies (425 participants) were selected for precision analyses. MR imaging–PDFF was linear with MR spectroscopy-PDFF (R2 = 0.96). Regression slope (0.97; P < .001) and mean Bland-Altman bias (−0.13%; 95% limits of agreement: −3.95%, 3.40%) indicated minimal underestimation by using MR imaging–PDFF. MR imaging–PDFF was precise at the region-of-interest level, with repeatability and reproducibility coefficients of 2.99% and 4.12%, respectively. Field strength, imager manufacturer, and reconstruction method each had minimal effects on reproducibility. Conclusion MR imaging–PDFF has excellent linearity, bias, and precision across different field strengths, imager manufacturers, and reconstruction methods. © RSNA, 2017 Online supplemental material is available for this article. An earlier incorrect version of this article appeared online. This article was corrected on October 2, 2017.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Preferred Reporting Items for Systematic Reviews and Meta-Analyses: the PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., Altman, D. G., & for the PRISMA Group (2009) · BMJ · doi:10.1136/bmj.b2535 · Cited by 83,823
Bias in meta-analysis detected by a simple, graphical test
Egger, M., Smith, G. D., Schneider, M., & Minder, C. (1997) · BMJ · doi:10.1136/bmj.315.7109.629 · Cited by 56,722
QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies
Whiting, P. F., Rutjes, A. W. S., Westwood, M. E., Mallett, S., Deeks, J. J., Reitsma, J. B., Leeflang, M. M. G., Sterne, J. A. C., Bossuyt, P. M. M., & the QUADAS-2 Group* (2011) · Annals of Internal Medicine · doi:10.7326/0003-4819-155-8-201110180-00009 · Cited by 14,199
Preferred reporting items for systematic reviews and meta-analyses: The PRISMA statement
Moher, D., Liberati, A., Tetzlaff, J., & Altman, D. G. (2010) · International Journal of Surgery · doi:10.1016/j.ijsu.2010.02.007 · Cited by 12,156
Nonalcoholic Fatty Liver Disease
Angulo, P. (2002) · New England Journal of Medicine · doi:10.1056/nejmra011775 · Cited by 5,228
Chalasani, N., Younossi, Z., Lavine, J. E., Diehl, A. M., Brunt, E. M., Cusi, K., Charlton, M., & Sanyal, A. J. (2012) · Hepatology · doi:10.1002/hep.25762 · Cited by 3,803
Whiting, P., Rutjes, A. W., Reitsma, J. B., Bossuyt, P. M., & Kleijnen, J. (2003) · BMC Medical Research Methodology · doi:10.1186/1471-2288-3-25 · Cited by 3,592
Hematological Problems in Pediatric Intensive Care
Revel-Vilk, S., Cox, P., Robitaille, N., & Blanchette, V. (2014) · Pediatric and Adolescent Medicine · doi:10.1159/000350346 · Cited by 3,508
Nonalcoholic fatty liver disease: a spectrum of clinical and pathological severity.
MATTEONI, C., YOUNOSSI, Z., GRAMLICH, T., BOPARAI, N., LIU, Y., & MCCULLOUGH, A. (1999) · Gastroenterology · doi:10.1016/s0016-5085(99)70506-8 · Cited by 3,345
The Natural History of Nonalcoholic Fatty Liver Disease: A Population-Based Cohort Study
Adams, L. A., Lymp, J. F., St. Sauver, J., Sanderson, S. O., Lindor, K. D., Feldstein, A., & Angulo, P. (2005) · Gastroenterology · doi:10.1053/j.gastro.2005.04.014 · Cited by 2,890
Sampling Variability of Liver Fibrosis in Chronic Hepatitis C
Bedossa, P., Dargère, D., & Paradis, V. (2003) · Hepatology · doi:10.1016/j.hep.2003.09.022 · Cited by 2,376
Long-term follow-up of patients with NAFLD and elevated liver enzymes
Ekstedt, M., Franzén, L. E., Mathiesen, U. L., Thorelius, L., Holmqvist, M., Bodemar, G., & Kechagias, S. (2006) · Hepatology · doi:10.1002/hep.21327 · Cited by 2,302
Sampling Variability of Liver Biopsy in Nonalcoholic Fatty Liver Disease
Ratziu, V., Charlotte, F., Heurtier, A., Gombert, S., Giral, P., Bruckert, E., Grimaldi, A., Capron, F., & Poynard, T. (2005) · Gastroenterology · doi:10.1053/j.gastro.2005.03.084 · Cited by 2,106
Bravo, A. A., Sheth, S. G., & Chopra, S. (2001) · New England Journal of Medicine · doi:10.1056/nejm200102153440706 · Cited by 2,041
Rockey, D. C., Caldwell, S. H., Goodman, Z. D., Nelson, R. C., & Smith, A. D. (2009) · Hepatology · doi:10.1002/hep.22742 · Cited by 1,997
Loomba, R., & Sanyal, A. J. (2013) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2013.171 · Cited by 1,641
Self-citationNonalcoholic fatty liver disease
Adams, L. A. (2005) · Canadian Medical Association Journal · doi:10.1503/cmaj.045232 · Cited by 1,610
Szczepaniak, L. S., Nurenberg, P., Leonard, D., Browning, J. D., Reingold, J. S., Grundy, S., Hobbs, H. H., & Dobbins, R. L. (2005) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00064.2004 · Cited by 1,562
Cohort Profile: The Study of Health in Pomerania
Volzke, H., Alte, D., Schmidt, C. O., Radke, D., Lorbeer, R., Friedrich, N., Aumann, N., Lau, K., Piontek, M., Born, G., et al. (2011) · International Journal of Epidemiology · doi:10.1093/ije/dyp394 · Cited by 1,000
Adams, L. A., Sanderson, S., Lindor, K. D., & Angulo, P. (2005) · Journal of Hepatology · doi:10.1016/j.jhep.2004.09.012 · Cited by 911
Quantitative assessment of liver fat with magnetic resonance imaging and spectroscopy
Reeder, S. B., Cruite, I., Hamilton, G., & Sirlin, C. B. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22580 · Cited by 822
Self-citationKnobloch, K., Yoon, U., & Vogt, P. M. (2011) · Journal of Cranio-Maxillofacial Surgery · doi:10.1016/j.jcms.2010.11.001 · Cited by 802
Wong, R. J., Cheung, R., & Ahmed, A. (2014) · Hepatology · doi:10.1002/hep.26986 · Cited by 723
Yu, H., Shimakawa, A., McKenzie, C. A., Brodsky, E., Brittain, J. H., & Reeder, S. B. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21737 · Cited by 694
Self-citationSanyal, A. J., Banas, C., Sargeant, C., Luketic, V. A., Sterling, R. K., Stravitz, R. T., Shiffman, M. L., Heuman, D., Coterrell, A., Fisher, R. A., et al. (2006) · Hepatology · doi:10.1002/hep.21103 · Cited by 522
In vivo characterization of the liver fat 1H MR spectrum
Hamilton, G., Yokoo, T., Bydder, M., Cruite, I., Schroeder, M. E., Sirlin, C. B., & Middleton, M. S. (2011) · NMR in Biomedicine · doi:10.1002/nbm.1622 · Cited by 520
Self-citationProton density fat‐fraction: A standardized mr‐based biomarker of tissue fat concentration
Reeder, S. B., Hu, H. H., & Sirlin, C. B. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23741 · Cited by 501
Self-citationWong, V. W.-S., Chu, W. C.-W., Wong, G. L.-H., Chan, R. S.-M., Chim, A. M.-L., Ong, A., Yeung, D. K.-W., Yiu, K. K.-L., Chu, S. H.-T., Woo, J., et al. (2012) · Gut · doi:10.1136/gutjnl-2011-300342 · Cited by 491
Raunig, D. L., McShane, L. M., Pennello, G., Gatsonis, C., Carson, P. L., Voyvodic, J. T., Wahl, R. L., Kurland, B. F., Schwarz, A. J., Gönen, M., et al. (2015) · Statistical Methods in Medical Research · doi:10.1177/0962280214537344 · Cited by 394
Proton MR spectroscopy in quantitative in vivo determination of fat content in human liver steatosis
Longo, R., Pollesello, P., Ricci, C., Masutti, F., Kvam, B. J., Bercich, L., Croce, L. S., Grigolato, P., Paoletti, S., De Bernard, B., et al. (1995) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880050311 · Cited by 387
Meisamy, S., Hines, C. D. G., Hamilton, G., Sirlin, C. B., McKenzie, C. A., Yu, H., Brittain, J. H., & Reeder, S. B. (2011) · Radiology · doi:10.1148/radiol.10100708 · Cited by 382
Self-citationEthnic differences in hepatic steatosis: An insulin resistance paradox?†
Guerrero, R., Vega, G. L., Grundy, S. M., & Browning, J. D. (2009) · Hepatology · doi:10.1002/hep.22726 · Cited by 368
Quantification of Liver Fat with Magnetic Resonance Imaging
Reeder, S. B., & Sirlin, C. B. (2010) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2010.08.013 · Cited by 342
Self-citationSitagliptin vs. placebo for non-alcoholic fatty liver disease: A randomized controlled trial
Cui, J., Philo, L., Nguyen, P., Hofflich, H., Hernandez, C., Bettencourt, R., Richards, L., Salotti, J., Bhatt, A., Hooker, J., et al. (2016) · Journal of Hepatology · doi:10.1016/j.jhep.2016.04.021 · Cited by 326
Self-citationWei, J. L., Leung, J. C.-F., Loong, T. C.-W., Wong, G. L.-H., Yeung, D. K.-W., Chan, R. S.-M., Chan, H. L.-Y., Chim, A. M.-L., Woo, J., Chu, W. C.-W., et al. (2015) · American Journal of Gastroenterology · doi:10.1038/ajg.2015.235 · Cited by 318
Scorletti, E., Bhatia, L., McCormick, K. G., Clough, G. F., Nash, K., Hodson, L., Moyses, H. E., Calder, P. C., Byrne, C. D., Sheron, N., et al. (2014) · Hepatology · doi:10.1002/hep.27289 · Cited by 310
Sullivan, S., Kirk, E. P., Mittendorfer, B., Patterson, B. W., & Klein, S. (2012) · Hepatology · doi:10.1002/hep.25548 · Cited by 301
Kessler, L. G., Barnhart, H. X., Buckler, A. J., Choudhury, K. R., Kondratovich, M. V., Toledano, A., Guimaraes, A. R., Filice, R., Zhang, Z., Sullivan, D. C., et al. (2015) · Statistical Methods in Medical Research · doi:10.1177/0962280214537333 · Cited by 293
Estimation of Hepatic Proton-Density Fat Fraction by Using MR Imaging at 3.0 T
Yokoo, T., Shiehmorteza, M., Hamilton, G., Wolfson, T., Schroeder, M. E., Middleton, M. S., Bydder, M., Gamst, A. C., Kono, Y., Kuo, A., et al. (2011) · Radiology · doi:10.1148/radiol.10100659 · Cited by 290
Self-citationZhang, H.-J., He, J., Pan, L.-L., Ma, Z.-M., Han, C.-K., Chen, C.-S., Chen, Z., Han, H.-W., Chen, S., Sun, Q., et al. (2016) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2016.3202 · Cited by 276
Wong, V. W.-S., Wong, G. L.-H., Yeung, D. K.-W., Abrigo, J. M., Kong, A. P.-S., Chan, R. S.-M., Chim, A. M.-L., Shen, J., Ho, C.-S., Woo, J., et al. (2014) · American Journal of Gastroenterology · doi:10.1038/ajg.2014.1 · Cited by 275
Noninvasive evaluation of NAFLD
Castera, L., Vilgrain, V., & Angulo, P. (2013) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2013.175 · Cited by 273
Kramer, H., Pickhardt, P. J., Kliewer, M. A., Hernando, D., Chen, G.-H., Zagzebski, J. A., & Reeder, S. B. (2017) · American Journal of Roentgenology · doi:10.2214/ajr.16.16565 · Cited by 252
Self-citationLe, T.-A., Chen, J., Changchien, C., Peterson, M. R., Kono, Y., Patton, H., Cohen, B. L., Brenner, D., Sirlin, C., & Loomba, R. (2012) · Hepatology · doi:10.1002/hep.25731 · Cited by 243
Self-citationEffect of PRESS and STEAM sequences on magnetic resonance spectroscopic liver fat quantification
Hamilton, G., Middleton, M. S., Bydder, M., Yokoo, T., Schwimmer, J. B., Kono, Y., Patton, H. M., Lavine, J. E., & Sirlin, C. B. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21809 · Cited by 215
Self-citationGuzman, G., Brunt, E. M., Petrovic, L. M., Chejfec, G., Layden, T. J., & Cotler, S. J. (2008) · Archives of Pathology & Laboratory Medicine · doi:10.5858/132.11.1761 · Cited by 212
Whole-Body MR Imaging in the German National Cohort: Rationale, Design, and Technical Background
Bamberg, F., Kauczor, H.-U., Weckbach, S., Schlett, C. L., Forsting, M., Ladd, S. C., Greiser, K. H., Weber, M.-A., Schulz-Menger, J., Niendorf, T., et al. (2015) · Radiology · doi:10.1148/radiol.2015142272 · Cited by 203
Hallsworth, K., Thoma, C., Hollingsworth, K. G., Cassidy, S., Anstee, Q. M., Day, C. P., & Trenell, M. I. (2015) · Clinical Science · doi:10.1042/cs20150308 · Cited by 201
Hines, C. D. G., Frydrychowicz, A., Hamilton, G., Tudorascu, D. L., Vigen, K. K., Yu, H., McKenzie, C. A., Sirlin, C. B., Brittain, J. H., & Reeder, S. B. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22514 · Cited by 201
Self-citationThe Netherlands Epidemiology of Obesity (NEO) study: study design and data collection
de Mutsert, R., den Heijer, M., Rabelink, T. J., Smit, J. W. A., Romijn, J. A., Jukema, J. W., de Roos, A., Cobbaert, C. M., Kloppenburg, M., le Cessie, S., et al. (2013) · European Journal of Epidemiology · doi:10.1007/s10654-013-9801-3 · Cited by 192
Yu, H., Shimakawa, A., Hines, C. D. G., McKenzie, C. A., Hamilton, G., Sirlin, C. B., Brittain, J. H., & Reeder, S. B. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22840 · Cited by 190
Self-citationISMRM workshop on fat–water separation: Insights, applications and progress in MRI
Hu, H. H., Börnert, P., Hernando, D., Kellman, P., Ma, J., Reeder, S., & Sirlin, C. (2012) · Magnetic Resonance in Medicine · doi:10.1002/mrm.24369 · Cited by 189
Self-citationKoopman, K. E., Caan, M. W. A., Nederveen, A. J., Pels, A., Ackermans, M. T., Fliers, E., la Fleur, S. E., & Serlie, M. J. M. (2014) · Hepatology · doi:10.1002/hep.27149 · Cited by 182
Patel, J., Bettencourt, R., Cui, J., Salotti, J., Hooker, J., Bhatt, A., Hernandez, C., Nguyen, P., Aryafar, H., Valasek, M., et al. (2016) · Therapeutic Advances in Gastroenterology · doi:10.1177/1756283x16656735 · Cited by 163
Self-citationKang, G. H., Cruite, I., Shiehmorteza, M., Wolfson, T., Gamst, A. C., Hamilton, G., Bydder, M., Middleton, M. S., & Sirlin, C. B. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22701 · Cited by 158
Self-citationKukuk, G. M., Hittatiya, K., Sprinkart, A. M., Eggers, H., Gieseke, J., Block, W., Moeller, P., Willinek, W. A., Spengler, U., Trebicka, J., et al. (2015) · European Radiology · doi:10.1007/s00330-015-3703-6 · Cited by 157
Self-citationBamberg, F., Hetterich, H., Rospleszcz, S., Lorbeer, R., Auweter, S., Schlett, C. L., Schafnitzel, A., Bayerl, C., Schindler, A., Saam, T., et al. (2016) · Diabetes · doi:10.2337/db16-0630 · Cited by 151
Self-citationSmits, M. M., Tonneijck, L., Muskiet, M. H. A., Kramer, M. H. H., Pouwels, P. J. W., Pieters-van den Bos, I. C., Hoekstra, T., Diamant, M., van Raalte, D. H., & Cahen, D. L. (2016) · Diabetologia · doi:10.1007/s00125-016-4100-7 · Cited by 142
Addressing phase errors in fat‐water imaging using a mixed magnitude/complex fitting method
Hernando, D., Hines, C. D. G., Yu, H., & Reeder, S. B. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.23044 · Cited by 136
Self-citationEffects of combined exenatide and pioglitazone therapy on hepatic fat content in type 2 diabetes
Sathyanarayana, P., Jogi, M., Muthupillai, R., Krishnamurthy, R., Samson, S. L., & Bajaj, M. (2011) · Obesity · doi:10.1038/oby.2011.152 · Cited by 124
Phase Maps Filtering Methods in Dixon Technique on Dedicated Low Field Scanners
Balbi, L., Caramella, D., Giunta, G., & Greco, D. (2012) · CINECA IRIS Institutial research information system (Parthenope University of Naples) · Cited by 110
Arulanandan, A., Ang, B., Bettencourt, R., Hooker, J. C., Behling, C. A., Lin, G., Valasek, M. A., Ix, J. H., Schnabl, B., Sirlin, C. B., et al. (2015) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2015.01.027 · Cited by 105
Self-citationMartino, M. D., Pacifico, L., Bezzi, M., Miscio, R. D., Sacconi, B., Chiesa, C., & Catalano, C. (2016) · World Journal of Gastroenterology · doi:10.3748/wjg.v22.i39.8812 · Cited by 104
Serai, S. D., Dillman, J. R., & Trout, A. T. (2017) · Radiology · doi:10.1148/radiol.2017161786 · Cited by 97
Self-citationQuantitative chemical shift-encoded MRI is an accurate method to quantify hepatic steatosis
Kühn, J., Hernando, D., Mensel, B., Krüger, P. C., Ittermann, T., Mayerle, J. V., Hosten, N., & Reeder, S. B. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24289 · Cited by 93
Self-citationPapamiltiadous, E. S., Roberts, S. K., Nicoll, A., Ryan, M. C., Itsiopoulos, C., Salim, A., & Tierney, A. C. (2016) · BMC Gastroenterology · doi:10.1186/s12876-016-0426-3 · Cited by 93
Artz, N. S., Haufe, W. M., Hooker, C. A., Hamilton, G., Wolfson, T. J., Campos, G. M., Gamst, A. C., Schwimmer, J. B., Sirlin, C. B., & Reeder, S. B. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24842 · Cited by 88
Self-citationBashir, M. R., Zhong, X., Nickel, D. M., Fananapazir, G., Kannengießer, S., Kiefer, B., & Dale, B. M. (2015) · American Journal of Roentgenology · doi:10.2214/ajr.14.12457 · Cited by 84
Self-citationReproducibility of hepatic fat fraction measurement by magnetic resonance imaging
Mashhood, A., Railkar, R. A., Yokoo, T., Levin, Y. S., Clark, L., Fox‐Bosetti, S., Middleton, M. S., Riek, J. K., Kauh, E. A., Dardzinski, B. J., et al. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23928 · Cited by 79
Self-citationBhatia, L. S., Scorletti, E., Curzen, N. P., Clough, G. F., Calder, P. C., & Byrne, C. D. (2015) · Atherosclerosis · doi:10.1016/j.atherosclerosis.2015.12.028 · Cited by 72
Rehm, J. L., Wolfgram, P. M., Hernando, D., Eickhoff, J. C., Allen, D. B., & Reeder, S. B. (2015) · European Radiology · doi:10.1007/s00330-015-3724-1 · Cited by 71
Self-citationTyagi, A., Yeganeh, O., Levin, Y. S., Hooker, J. C., Hamilton, G., Wolfson, T. J., Gamst, A. C., Zand, A. K., Heba, E. R., Loomba, R. S., et al. (2015) · Abdominal Imaging · doi:10.1007/s00261-015-0542-5 · Cited by 68
Self-citationRubinstein, E., Lavine, J., & Schwimmer, J. (2008) · Seminars in Liver Disease · doi:10.1055/s-0028-1091982 · Cited by 60 · cited 1×
“J Magn Reson Imaging 2012;36(5):1011–1014.”
Vu, K., Gilbert, G., Chalut, M., Chagnon, M., Chartrand, G., & Tang, A. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25083 · Cited by 58
Self-citationNegrete, L. M., Middleton, M. S., Clark, L., Wolfson, T. J., Gamst, A. C., Lam, J., Changchien, C., Deyoung-Dominguez, I. M., Hamilton, G., Loomba, R. S., et al. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24284 · Cited by 57
Self-citationT1 bias in chemical shift‐encoded liver fat‐fraction: Role of the flip angle
Kühn, J., Jahn, C., Hernando, D., Siegmund, W., Hadlich, S., Mayerle, J. V., Pfannmöller, J. P., Langner, S., & Reeder, S. B. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24457 · Cited by 54
Self-citationSofue, K., Mileto, A., Dale, B. M., Zhong, X., & Bashir, M. R. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24922 · Cited by 50
Self-citationQuantification of liver fat with respiratory‐gated quantitative chemical shift encoded MRI
Motosugi, U., Hernando, D., Bannas, P., Holmes, J. H., Wang, K., Shimakawa, A. S., Iwadate, Y., Taviani, V., Rehm, J. L., & Reeder, S. B. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24896 · Cited by 31
Self-citationVogt, L., Steveling, A., Meffert, P. J., Kromrey, M., Keßler, R., Hosten, N., Krüger, J., Gärtner, S., Aghdassi, A. A., Mayerle, J. V., et al. (2016) · PLoS ONE · doi:10.1371/journal.pone.0153595 · Cited by 31
Self-citationThe effects of concomitant gradients on chemical shift encoded MRI
Colgan, T. J., Hernando, D., Sharma, S. D., & Reeder, S. B. (2016) · Magnetic Resonance in Medicine · doi:10.1002/mrm.26461 · Cited by 31
Self-citationTang, A., Chen, J. R., Le, T., Changchien, C., Hamilton, G., Middleton, M. S., Loomba, R. S., & Sirlin, C. B. (2014) · Abdominal Imaging · doi:10.1007/s00261-014-0175-0 · Cited by 30
Self-citationZand, K. A., Shah, A., Heba, E. R., Wolfson, T. J., Hamilton, G., Lam, J., Chen, J., Hooker, J. C., Gamst, A. C., Middleton, M. S., et al. (2015) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24888 · Cited by 28
Self-citationKim, K. Y., Song, J. S., Kannengießer, S., & Han, Y. M. (2015) · La radiologia medica · doi:10.1007/s11547-015-0545-x · Cited by 27
Self-citationWu, B., Han, W., Li, Z., et al. (2016) · Scientific Reports · doi:10.1038/srep19339 · Cited by 24
Levin, Y. S., Yokoo, T., Wolfson, T. J., Gamst, A. C., Collins, J., Achmad, E., Hamilton, G., Middleton, M. S., Loomba, R. S., & Sirlin, C. B. (2013) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.24193 · Cited by 22
Self-citationRajeev, S. P., Sprung, V. S., Roberts, C. A., Harrold, J. A., Halford, J. C. G., Stančák, A., Boyland, E. J., Kemp, G. J., Cuthbertson, D. J., & Wilding, J. P. H. (2017) · BMJ Open · doi:10.1136/bmjopen-2016-013539 · Cited by 20
Park, C. C., Hamilton, G., Desai, A. S., Zand, K. A., Wolfson, T. J., Hooker, J. C., Costa, E., Heba, E. R., Clark, L., Gamst, A. C., et al. (2016) · Abdominal Radiology · doi:10.1007/s00261-016-0992-4 · Cited by 9
Self-citation
Cited by
Noninvasive assessment of liver disease in patients with nonalcoholic fatty liver disease
Castera, L., Friedrich-Rust, M., & Loomba, R. (2019) · Gastroenterology · doi:10.1053/j.gastro.2018.12.036 · Cited by 1,494
Self-citationShukla‐Dave, A., Obuchowski, N. A., Chenevert, T. L., Jambawalikar, S., Schwartz, L. H., Malyarenko, D., Huang, W., Noworolski, S. M., Young, R. J., Shiroishi, M. S., et al. (2019) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.26518 · Cited by 389
Self-citationQuantification of liver fat content with CT and MRI: state of the art
Starekova, J., Hernando, D., Pickhardt, P. J., & Reeder, S. B. (2021) · Radiology · doi:10.1148/radiol.2021204288 · Cited by 320
Liver fat imaging—a clinical overview of ultrasound, CT, and MR imaging
Zhang, Y. N., Fowler, K. J., Hamilton, G., Cui, J. Y., Sy, E. Z., Balanay, M., Hooker, J. C., Szeverenyi, N., & Sirlin, C. B. (2018) · The British Journal of Radiology · doi:10.1259/bjr.20170959 · Cited by 304
Self-citationStine, J. G., Munaganuru, N., Barnard, A., Wang, J. L., Kaulback, K., Argo, C. K., Singh, S., Fowler, K. J., Sirlin, C. B., & Loomba, R. (2021) · Clinical Gastroenterology and Hepatology · doi:10.1016/j.cgh.2020.08.061 · Cited by 283
Self-citation
Metadata
- Authors
- Yokoo, T., Serai, S. D., Pirasteh, A., Bashir, M. R., Hamilton, G., Hernando, D., Hu, H. H., Hetterich, H., Kühn, J.-P., Kukuk, G. M., Loomba, R., Middleton, M. S., Obuchowski, N. A., Song, J. S., Tang, A., Wu, X., Reeder, S. B., Sirlin, C. B., & For the RSNA-QIBA PDFF Biomarker Committee
- Venue
- Radiology
- Published
- 2018-02
- Volume
- 286
- Issue
- 2
- Pages
- 486-498
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2755909350
- Cited by
- 338
- References
- 87
- FWCI
- 4.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.