The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
ECG-gated Reconstructed Multi–Detector Row CT Coronary Angiography: Effect of Varying Trigger Delay on Image Quality
Abstract
PURPOSE: To evaluate the effectiveness of electrocardiographically (ECG)-gated retrospective image reconstruction for multi-detector row computed tomographic (CT) coronary angiography in reducing cardiac motion artifacts and to evaluate the influence of heart rate on cardiac image quality. MATERIALS AND METHODS: Sixty-five patients with different heart rates underwent coronary CT angiography. Raw helical CT data and ECG tracings were combined to retrospectively reconstruct at the defined consecutive z position with a temporal resolution of 250 msec per section. The starting points of the reconstruction were chosen between 30% and 80% of the R-R intervals. The relationships between heart rate, trigger delay, and image quality were analyzed. RESULTS: Optimal image quality was achieved with a 50% trigger delay for the right coronary artery and 60% for the left circumflex coronary artery. Optimal image quality for the left anterior descending coronary artery was equally obtained at 50% and 60% triggering. A significant negative correlation was observed between heart rate and image quality (P <.05). The best image quality was achieved when the heart rate was less than 74.5 beats per minute. CONCLUSION: To achieve high image quality, the heart rate should be sufficiently slow. Selection of appropriate trigger delays and a decreasing heart rate are effective to reduce cardiac motion artifacts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786 · cited 1×
“Electron-beam CT with prospective ECG triggering (3) is currently estab-”
BackgroundAusten, W., Edwards, J., Frye, R., Gensini, G., Gott, V., Griffith, L., McGoon, D., Murphy, M., & Roe, B. (1975) · Circulation · doi:10.1161/01.cir.51.4.5 · Cited by 3,256
Arad, Y., Spadaro, L. A., Goodman, K., Lledo-Perez, A., Sherman, S., Lerner, G., & Guerci, A. D. (1996) · Circulation · doi:10.1161/01.cir.93.11.1951 · Cited by 521
Ohnesorge, B., Flohr, T., Becker, C., Kopp, A. F., Schoepf, U. J., Baum, U., Knez, A., Klingenbeck-Regn, K., & Reiser, M. F. (2000) · Radiology · doi:10.1148/radiology.217.2.r00nv30564 · Cited by 516
Self-citationBudoff, M. J., Georgiou, D., Brody, A., Agatston, A. S., Kennedy, J., Wolfkiel, C., Stanford, W., Shields, P., Lewis, R. J., Janowitz, W. R., et al. (1996) · Circulation · doi:10.1161/01.cir.93.5.898 · Cited by 488
Coronary Artery Calcium Measurement: Agreement of Multirow Detector and Electron Beam CT
Becker, C. R., Kleffel, T., Crispin, A., Knez, A., Young, J., Schoepf, U. J., Haberl, R., & Reiser, M. F. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.5.1761295 · Cited by 282
Self-citationChanges in diastolic time with various pharmacologic agents: implication for myocardial perfusion.
Boudoulas, H., Rittgers, S. E., Lewis, R. P., Leier, C. V., & Weissler, A. M. (1979) · Circulation · doi:10.1161/01.cir.60.1.164 · Cited by 206
Moshage, W. E., Achenbach, S., Seese, B., Bachmann, K., & Kirchgeorg, M. (1995) · Radiology · doi:10.1148/radiology.196.3.7644633 · Cited by 205
Hofman, M. B. M., Wickline, S. A., & Lorenz, C. H. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080309 · Cited by 186
Schmermund, A., Rensing, B. J., Sheedy, P. F., Bell, M. R., & Rumberger, J. A. (1998) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(98)00132-6 · Cited by 180
Budoff, M. J., Oudiz, R. J., Zalace, C. P., Bakhsheshi, H., Goldberg, S. L., French, W. J., Rami, T. G., & Brundage, B. H. (1999) · The American Journal of Cardiology · doi:10.1016/s0002-9149(98)01075-3 · Cited by 140
Becker, C. R., Jakobs, T. F., Aydemir, S., Becker, A., Knez, A., Schoepf, U. J., Bruening, R. D., Haberl, R., & Reiser, M. F. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.2.1740543 · Cited by 138
Self-citationIntravenous Coronary Angiography by Electron Beam Computed Tomography
Rensing, B. J. W. M., Bongaerts, A. H. H., van Geuns, R., van Ooijen, P. M. A., Oudkerk, M., & de Feyter, P. J. (1998) · Circulation · doi:10.1161/01.cir.98.23.2509 · Cited by 128
Detection and quantification of coronary artery calcification with electron-beam and conventional CT
Becker, C. R., Knez, A., Jakobs, T., Aydemir, S., Becker, A., Schoepf, U. J., Bruening, R., Haberl, R., & Reiser, M. F. (1999) · European Radiology · doi:10.1007/s003300050720 · Cited by 113
Self-citation
Cited by
First performance evaluation of a dual-source CT (DSCT) system
Flohr, T. G., McCollough, C. H., Bruder, H., Petersilka, M., Gruber, K., Süβ, C., Grasruck, M., Stierstorfer, K., Krauss, B., Raupach, R., et al. (2006) · European Radiology · doi:10.1007/s00330-005-2919-2 · Cited by 1,413
Self-citationLeber, A. W., Knez, A., Becker, A., Becker, C., von Ziegler, F., Nikolaou, K., Rist, C., Reiser, M., White, C., Steinbeck, G., et al. (2004) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2003.10.059 · Cited by 662
Self-citationEarls, J. P., Berman, E. L., Urban, B. A., Curry, C. A., Lane, J. L., Jennings, R. S., McCulloch, C. C., Hsieh, J., & Londt, J. H. (2008) · Radiology · doi:10.1148/radiol.2463070989 · Cited by 543
Multi–Detector Row CT Systems and Image-Reconstruction Techniques
Flohr, T. G., Schaller, S., Stierstorfer, K., Bruder, H., Ohnesorge, B. M., & Schoepf, U. J. (2005) · Radiology · doi:10.1148/radiol.2353040037 · Cited by 381
Self-citationSchoepf, U. J., Becker, C. R., Ohnesorge, B. M., & Yucel, E. K. (2004) · Radiology · doi:10.1148/radiol.2321030636 · Cited by 356
Self-citation
Metadata
- Authors
- Hong, C., Becker, C. R., Huber, A., Schoepf, U. J., Ohnesorge, B., Knez, A., Brüning, R., & Reiser, M. F.
- Venue
- Radiology
- Published
- 2001-09
- Volume
- 220
- Issue
- 3
- Pages
- 712-717
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2138425831
- Cited by
- 255
- References
- 14
- FWCI
- 23.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.