Pulmonary Embolism: Optimization of Small Pulmonary Artery Visualization at Multi–Detector Row CT
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
PURPOSE: To compare the frequency of well-visualized pulmonary arteries according to anatomic level by using different collimation with single- and multi-detector row computed tomography (CT) in patients suspected of having acute pulmonary embolism. MATERIALS AND METHODS: Sixty patients were examined with one of three techniques (20 patients each). Group 1 was examined with single-detector row CT with 3-mm collimation and 1.3-1.6 pitch; groups 2 and 3, with multi-detector row CT with 2.5- and 1.25-mm collimation, respectively. Three thoracic radiologists independently reviewed examination findings to determine if each main, lobar, segmental, and subsegmental artery was well visualized for presence of pulmonary embolism. chi2 tests were performed. For well-visualized vessels, the presence and/or absence of pulmonary embolism was recorded and kappa statistic was determined. RESULTS: Reader 1 scored 95% (114 of 120), 96% (115 of 120), and 99% (119 of 120) of lobar arteries (P >.05); 76% (304 of 400), 86% (346 of 400), and 91% (363 of 400) of segmental arteries (P <.001); and 37% (300 of 800), 56% (448 of 800), and 76% (608 of 800) of subsegmental arteries as well visualized (P <.001) using techniques 1, 2, and 3, respectively. Reader 2 scored 97% (116 of 120), 95% (114 of 120), and 99% (119 of 120) of lobar arteries (P >.05); 77% (308 of 400), 87% (349 of 400), and 93% (371 of 400) of segmental arteries (P <.001); and 39% (310 of 800), 53% (422 of 800), and 78% (621 of 800) of subsegmental arteries (P <.001) as well visualized using techniques 1, 2, and 3, respectively. Reader 3 scored 86% (103 of 120), 82% (98 of 120), and 91% (109 of 120) of lobar arteries (P >.05); 63% (252 of 400), 70% (280 of 400), and 85% (339 of 400) of segmental arteries (P <.001); and 39% (310 of 800), 56% (451 of 800), and 71% (572 of 800) of subsegmental arteries (P <.001) as well visualized using techniques 1, 2, and 3, respectively. Sixteen patients had pulmonary embolism. Interobserver agreement for detection of pulmonary embolism was significantly better for segmental and subsegmental arteries for all readers with technique 3 (segmental, kappa = 0.79-0.80; subsegmental, kappa = 0.71-0.76) than that with technique 1 (segmental, kappa = 0.47-0.75; subsegmental, kappa = 0.28-0.54). CONCLUSION: Multi-detector row CT at 1.25-mm collimation significantly improves visualization of segmental and subsegmental arteries and interobserver agreement in detection of pulmonary embolism.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Anderson, F. A. (1991) · Archives of Internal Medicine · doi:10.1001/archinte.1991.00400050081016 · Cited by 1,669
Natural history of pulmonary embolism
Dalen, J. E., & Alpert, J. S. (1975) · Progress in Cardiovascular Diseases · doi:10.1016/s0033-0620(75)80017-x · Cited by 1,124
Clinical biostatistics: LIV. The biostatistics of concordance
Kramer, M. S., & Feinstein, A. R. (1981) · Clinical Pharmacology and Therapeutics · doi:10.1038/clpt.1981.18 · Cited by 1,087
The Clinical Course of Pulmonary Embolism
Carson, J. L., Kelley, M. A., Duff, A., Weg, J. G., Fulkerson, W. J., Palevsky, H. I., Schwartz, J. S., Thompson, B. T., Popovich, J., Hobbins, T. E., et al. (1992) · New England Journal of Medicine · doi:10.1056/nejm199205073261902 · Cited by 1,039
Remy-Jardin, M., Remy, J., Wattinne, L., & Giraud, F. (1992) · Radiology · doi:10.1148/radiology.185.2.1410342 · Cited by 788
Complications and validity of pulmonary angiography in acute pulmonary embolism.
Stein, P. D., Athanasoulis, C., Alavi, A., Greenspan, R. H., Hales, C. A., Saltzman, H. A., Vreim, C. E., Terrin, M. L., & Weg, J. G. (1992) · Circulation · doi:10.1161/01.cir.85.2.462 · Cited by 669
Prevalence of Acute Pulmonary Embolism Among Patients in a General Hospital and at Autopsy
Stein, P. D., & Henry, J. W. (1995) · Chest · doi:10.1378/chest.108.4.978 · Cited by 645
Diagnosis of Pulmonary Embolism with Magnetic Resonance Angiography
Meaney, J. F. M., Weg, J. G., Chenevert, T. L., Stafford-Johnson, D., Hamilton, B. H., & Prince, M. R. (1997) · New England Journal of Medicine · doi:10.1056/nejm199705153362004 · Cited by 482
Peripheral Pulmonary Arteries: How Far in the Lung Does Multi-Detector Row Spiral CT Allow Analysis?
Ghaye, B., Szapiro, D., Mastora, I., Delannoy, V., Duhamel, A., Remy, J., & Remy-Jardin, M. (2001) · Radiology · doi:10.1148/radiology.219.3.r01jn32629 · Cited by 344
Cited by
Konstantinides, S. V., Meyer, G., Becattini, C., Bueno, H., Geersing, G.-J., Harjola, V.-P., Huisman, M. V., Humbert, M., Jennings, C. S., Jiménez, D., et al. (2020) · European Heart Journal · doi:10.1093/eurheartj/ehz405 · Cited by 4,916
2014 ESC Guidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Konstantinides, S. V., Torbicki, A., Agnelli, G., Danchin, N., Fitzmaurice, D., Galiè, N., Gibbs, J. S. R., Huisman, M. V., Humbert, M., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu283 · Cited by 3,128
Guidelines on the diagnosis and management of acute pulmonary embolism
Authors/Task Force Members, Torbicki, A., Perrier, A., Konstantinides, S., Agnelli, G., Galiè, N., Pruszczyk, P., Bengel, F., Brady, A. J. B., Ferreira, D., et al. (2008) · European Heart Journal · doi:10.1093/eurheartj/ehn310 · Cited by 2,826
Multidetector Computed Tomography for Acute Pulmonary Embolism
Stein, P. D., Fowler, S. E., Goodman, L. R., Gottschalk, A., Hales, C. A., Hull, R. D., Leeper, K. V., Popovich, J., Quinn, D. A., Sos, T. A., et al. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa052367 · Cited by 1,660
Konstantinides, S. V., Meyer, G., Becattini, C., Bueno, H., Geersing, G.-J., Harjola, V.-P., Huisman, M. V., Humbert, M., Jennings, C. S., Jiménez, D., et al. (2019) · European Respiratory Journal · doi:10.1183/13993003.01647-2019 · Cited by 1,619
Quiroz, R., Kucher, N., Zou, K. H., Kipfmueller, F., Costello, P., Goldhaber, S. Z., & Schoepf, U. J. (2005) · JAMA · doi:10.1001/jama.293.16.2012 · Cited by 313
Venous thromboembolism in the ICU: main characteristics, diagnosis and thromboprophylaxis
Minet, C., Potton, L., Bonadona, A., Hamidfar-Roy, R., Somohano, C. A., Lugosi, M., Cartier, J.-C., Ferretti, G., Schwebel, C., & Timsit, J.-F. (2015) · Critical Care · doi:10.1186/s13054-015-1003-9 · Cited by 270
Schueller-Weidekamm, C., Schaefer-Prokop, C. M., Weber, M., Herold, C. J., & Prokop, M. (2006) · Radiology · doi:10.1148/radiol.2413040128 · Cited by 258
Lung Perfusion with Dual-energy Multidetector-row CT (MDCT)
Pontana, F., Faivre, J.-B., Remy-Jardin, M., Flohr, T., Schmidt, B., Tacelli, N., Pansini, V., & Remy, J. (2008) · Academic Radiology · doi:10.1016/j.acra.2008.05.018 · Cited by 233
Low-Dose Unenhanced Multidetector CT of Patients with Suspected Renal Colic
Tack, D., Sourtzis, S., Delpierre, I., de Maertelaer, V., & Gevenois, P. A. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.180.2.1800305 · Cited by 225
Metadata
- Authors
- Patel, S., Kazerooni, E. A., & Cascade, P. N.
- Venue
- Radiology
- Published
- 2003-05
- Volume
- 227
- Issue
- 2
- Pages
- 455-460
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2126220861
- Cited by
- 274
- References
- 13
- FWCI
- 12.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.