In Vivo MR Imaging of Intravascularly Injected Magnetically Labeled Mesenchymal Stem Cells in Rat Kidney and Liver
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate in vivo magnetic resonance (MR) imaging with a conventional 1.5-T system for depiction and tracking of intravascularly injected superparamagnetic iron oxide (SPIO)-labeled mesenchymal stem cells (MSCs). MATERIALS AND METHODS: This study was conducted in accordance with French law governing animal research and met guidelines for animal care and use. Rat MSCs were labeled with SPIO and transfection agent. Relaxation rates at 1.5 T, cell viability, proliferation, differentiation capacity, and labeling stability were assessed in vitro as a function of SPIO concentration. MSCs were injected into renal arteries of healthy rats (labeled cells in four, unlabeled cells in two) and portal veins of rats treated with carbon tetrachloride to induce centrolobular liver necrosis (labeled cells and unlabeled cells in two each). Follow-up serial T2*-weighted gradient-echo MR imaging and R2* mapping were performed. MR imaging findings were compared histologically. RESULTS: SPIO labeling caused a strong R2* effect that increased linearly with iron dose; R2* increase for cells labeled for 48 hours with 50 microg of iron per milliliter was 50 sec(-1) per million cells per milliliter. R2* was proportional to iron load of cells. SPIO labeling did not affect cell viability (P > .27). Labeled cells were able to differentiate into adipocytes and osteocytes. Proliferation was substantially limited for MSCs labeled with 100 microg Fe/mL or greater. Label half-life was longer than 11 days. In normal kidneys, labeled MSCs caused signal intensity loss in renal cortex. After labeled MSC injection, diseased liver had diffuse granular appearance. Cells were detected for up to 7 days in kidney and 12 days in liver. Signal intensity loss and fading over time were confirmed with serial R2* mapping. At histologic analysis, signal intensity loss correlated with iron-loaded cells, primarily in renal glomeruli and hepatic sinusoids; immunohistochemical analysis results confirmed these cells were MSCs. CONCLUSION: MR imaging can aid in monitoring of intravascularly administered SPIO-labeled MSCs in vivo in kidney and liver.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
1 retracted
RETRACTED ARTICLE: Pluripotency of mesenchymal stem cells derived from adult marrow
Jiang, Y., Jahagirdar, B. N., Reinhardt, R. L., Schwartz, R. E., Keene, C. D., Ortiz-Gonzalez, X. R., Reyes, M., Lenvik, T., Lund, T., Blackstad, M., et al. (2002) · Nature · doi:10.1038/nature00870 · Cited by 5,518
RetractedMultilineage potential of adult human mesenchymal stem cells
Pittenger, M. F., Mackay, A. M., Beck, S. C., Jaiswal, R. K., Douglas, R., Mosca, J. D., Moorman, M. A., Simonetti, D. W., Craig, S., & Marshak, D. R. (1999) · Science · doi:10.1126/science.284.5411.143 · Cited by 21,052
Lewin, M., Carlesso, N., Tung, C.-H., Tang, X.-W., Cory, D., Scadden, D. T., & Weissleder, R. (2000) · Nature Biotechnology · doi:10.1038/74464 · Cited by 1,716
Mangi, A. A., Noiseux, N., Kong, D., He, H., Rezvani, M., Ingwall, J. S., & Dzau, V. J. (2003) · Nature Medicine · doi:10.1038/nm912 · Cited by 1,509
Magnetodendrimers allow endosomal magnetic labeling and in vivo tracking of stem cells
Bulte, J. W. M., Douglas, T., Witwer, B., Zhang, S.-C., Strable, E., Lewis, B. K., Zywicke, H., Miller, B., van Gelderen, P., Moskowitz, B. M., et al. (2001) · Nature Biotechnology · doi:10.1038/nbt1201-1141 · Cited by 1,027
Self-citationDevine, S. M., Cobbs, C., Jennings, M., Bartholomew, A., & Hoffman, R. (2003) · Blood · doi:10.1182/blood-2002-06-1830 · Cited by 740
In Vivo Magnetic Resonance Imaging of Mesenchymal Stem Cells in Myocardial Infarction
Kraitchman, D. L., Heldman, A. W., Atalar, E., Amado, L. C., Martin, B. J., Pittenger, M. F., Hare, J. M., & Bulte, J. W. M. (2003) · Circulation · doi:10.1161/01.cir.0000070931.62772.4e · Cited by 710
Self-citationHoehn, M., Küstermann, E., Blunk, J., Wiedermann, D., Trapp, T., Wecker, S., Föcking, M., Arnold, H., Hescheler, J., Fleischmann, B. K., et al. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.242435499 · Cited by 707
Frank, J. A., Miller, B. R., Arbab, A. S., Zywicke, H. A., Jordan, E. K., Lewis, B. K., Bryant, L. H., & Bulte, J. W. M. (2003) · Radiology · doi:10.1148/radiol.2281020638 · Cited by 643
Self-citationBulte, J. W. M., Zhang, S.-C., van Gelderen, P., Herynek, V., Jordan, E. K., Duncan, I. D., & Frank, J. A. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.26.15256 · Cited by 531
Self-citationSerial Cardiac Magnetic Resonance Imaging of Injected Mesenchymal Stem Cells
Hill, J. M., Dick, A. J., Raman, V. K., Thompson, R. B., Yu, Z.-X., Hinds, K. A., Pessanha, B. S. S., Guttman, M. A., Varney, T. R., Martin, B. J., et al. (2003) · Circulation · doi:10.1161/01.cir.0000084537.66419.7a · Cited by 458
Gene therapy of experimental brain tumors using neural progenitor cells
Benedetti, S., Pirola, B., Pollo, B., Magrassi, L., Bruzzone, M. G., Rigamonti, D., Galli, R., Selleri, S., Di Meco, F., De Fraja, C., et al. (2000) · Nature Medicine · doi:10.1038/74710 · Cited by 456
Galmiche, M., Koteliansky, V., Briere, J., Herve, P., & Charbord, P. (1993) · Blood · doi:10.1182/blood.v82.1.66.bloodjournal82166 · Cited by 362
Self-citationBone Marrow Is a Reservoir of Repopulating Mesangial Cells during Glomerular Remodeling
Ito, T., Suzuki, A., Imai, E., Okabe, M., & Hori, M. (2001) · Journal of the American Society of Nephrology · doi:10.1681/asn.v12122625 · Cited by 345
Modo, M., Cash, D., Mellodew, K., Williams, S. C. R., Fraser, S. E., Meade, T. J., Price, J., & Hodges, H. (2002) · NeuroImage · doi:10.1006/nimg.2002.1194 · Cited by 268
Regulation of Smooth Muscle Actin Expression and Contraction in Adult Human Mesenchymal Stem Cells
Kinner, B., Zaleskas, J. M., & Spector, M. (2002) · Experimental Cell Research · doi:10.1006/excr.2002.5561 · Cited by 232
Application of the static dephasing regime theory to superparamagnetic iron‐oxide loaded cells
Bowen, C. V., Zhang, X., Saab, G., Gareau, P. J., & Rutt, B. K. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10192 · Cited by 226
The Potential of Bone Marrow-Derived Cells to Differentiate to Glomerular Mesangial Cells
IMASAWA, T., UTSUNOMIYA, Y., KAWAMURA, T., ZHONG, Y., NAGASAWA, R., OKABE, M., MARUYAMA, N., HOSOYA, T., & OHNO, T. (2001) · Journal of the American Society of Nephrology · doi:10.1681/asn.v1271401 · Cited by 216
Dodd, C. H., Hsu, H.-C., Chu, W.-J., Yang, P., Zhang, H.-G., Mountz, J. D., Zinn, K., Forder, J., Josephson, L., Weissleder, R., et al. (2001) · Journal of Immunological Methods · doi:10.1016/s0022-1759(01)00433-1 · Cited by 212
Imaging single mammalian cells with a 1.5 T clinical MRI scanner
Foster‐Gareau, P., Heyn, C., Alejski, A., & Rutt, B. K. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10417 · Cited by 207
Targeting of Hematopoietic Progenitor Cells with MR Contrast Agents
Daldrup-Link, H. E., Rudelius, M., Oostendorp, R. A. J., Settles, M., Piontek, G., Metz, S., Rosenbrock, H., Keller, U., Heinzmann, U., Rummeny, E. J., et al. (2003) · Radiology · doi:10.1148/radiol.2283020322 · Cited by 200
Improved molecular imaging contrast agent for detection of human thrombus
Winter, P. M., Caruthers, S. D., Yu, X., Song, S., Chen, J., Miller, B., Bulte, J. W. M., Robertson, J. D., Gaffney, P. J., Wickline, S. A., et al. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10532 · Cited by 189
Self-citationAhrens, E. T., Feili‐Hariri, M., Xu, H., Genove, G., & Morel, P. A. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10465 · Cited by 168
Specific MR imaging of human lymphocytes by monoclonal antibody‐guided dextran‐magnetite particles
Bulte, J. W. M., Hoekstra, Y., Kamman, R. L., Magin, R. L., Webb, A. G., Briggs, R. W., Gwan Go, K., Hulstaert, C. E., Miltenyi, S., Hauw The, T., et al. (1992) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910250115 · Cited by 148
Self-citationRole of Mesenchymal Cell Populations in Porcine Serum–Induced Rat Liver Fibrosis
Bhunchet, E., & Wake, K. (1992) · Hepatology · doi:10.1002/hep.1840160623 · Cited by 127
MRI of insulitis in autoimmune diabetes
Moore, A., Zhe Sun, P., Cory, D., Högemann, D., Weissleder, R., & Lipes, M. A. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10110 · Cited by 99
Magnetic resonance imaging of transplanted oligodendrocyte precursors in the rat brain
Franklin, R. J. M., Blaschuk, K. L., Bearchell, M. C., Prestoz, L. L. C., Setzu, A., Brindle, K. M., & ffrench-Constant, C. (1999) · NeuroReport · doi:10.1097/00001756-199912160-00043 · Cited by 75
Cultured rat mesangial cells contain smooth muscle alpha-actin not found in vivo.
Elger, M., Drenckhahn, D., Nobiling, R., Mundel, P. H., & Kriz, W. (1993) · PubMed Central · Cited by 66
(1997) · doi:10.1002/(sici)1097-4644(199702)64:2<295::aid-jcb12>3.0.co;2-i
Cited by
Applications of Magnetic Nanoparticles in Biomedicine
Bárcena, C., Sra, A. K., & Gao, J. (2009) · Nanoscale Magnetic Materials and Applications · doi:10.1007/978-0-387-85600-1_20 · Cited by 2,565
Recent advances in iron oxide nanocrystal technology for medical imaging☆
COROT, C., ROBERT, P., IDEE, J., & PORT, M. (2006) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2006.09.013 · Cited by 1,465
Superparamagnetic Iron Oxide Nanoparticle Probes for Molecular Imaging
Thorek, D. L. J., Chen, A. K., Czupryna, J., & Tsourkas, A. (2006) · Annals of Biomedical Engineering · doi:10.1007/s10439-005-9002-7 · Cited by 772
Kidd, S., Spaeth, E., Dembinski, J. L., Dietrich, M., Watson, K., Klopp, A., Battula, V. L., Weil, M., Andreeff, M., & Marini, F. C. (2009) · Stem Cells · doi:10.1002/stem.187 · Cited by 679
Zheng, B., von See, M. P., Yu, E., Gunel, B., Lu, K., Vazin, T., Schaffer, D. V., Goodwill, P. W., & Conolly, S. M. (2016) · Theranostics · doi:10.7150/thno.13728 · Cited by 322
Metadata
- Authors
- Bos, C., Delmas, Y., Desmoulière, A., Solanilla, A., Hauger, O., Grosset, C., Dubus, I., Ivanovic, Z., Rosenbaum, J., Charbord, P., Combe, C., Bulte, J. W. M., Moonen, C. T. W., Ripoche, J., & Grenier, N.
- Venue
- Radiology
- Published
- 2004-12
- Volume
- 233
- Issue
- 3
- Pages
- 781-789
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2169928944
- Cited by
- 232
- References
- 29
- FWCI
- 8.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.