Perfusion Imaging of the Liver: Current Challenges and Future Goals
The DOI matches its Crossref record; 52 of the 52 references it cites were found in a registry or an index.
Abstract
Improved therapeutic options for hepatocellular carcinoma and metastatic disease place greater demands on diagnostic and surveillance tests for liver disease. Existing diagnostic imaging techniques provide limited evaluation of tissue characteristics beyond morphology; perfusion imaging of the liver has potential to improve this shortcoming. The ability to resolve hepatic arterial and portal venous components of blood flow on a global and regional basis constitutes the primary goal of liver perfusion imaging. Earlier detection of primary and metastatic hepatic malignancies and cirrhosis may be possible on the basis of relative increases in hepatic arterial blood flow associated with these diseases. To date, liver flow scintigraphy and flow quantification at Doppler ultrasonography have focused on characterization of global abnormalities. Computed tomography (CT) and magnetic resonance (MR) imaging can provide regional and global parameters, a critical goal for tumor surveillance. Several challenges remain: reduced radiation doses associated with CT perfusion imaging, improved spatial and temporal resolution at MR imaging, accurate quantification of tissue contrast material at MR imaging, and validation of parameters obtained from fitting enhancement curves to biokinetic models, applicable to all perfusion methods. Continued progress in this new field of liver imaging may have profound implications for large patient groups at risk for liver disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Mazzaferro, V., Regalia, E., Doci, R., Andreola, S., Pulvirenti, A., Bozzetti, F., Montalto, F., Ammatuna, M., Morabito, A., & Gennari, L. (1996) · New England Journal of Medicine · doi:10.1056/nejm199603143341104 · Cited by 7,186
Estimating the world cancer burden: Globocan 2000
Parkin, D. M., Bray, F., Ferlay, J., & Pisani, P. (2001) · International Journal of Cancer · doi:10.1002/ijc.1440 · Cited by 3,721
Role of angiogenesis in tumor growth and metastasis
Folkman, J. (2002) · Seminars in Oncology · doi:10.1053/sonc.2002.37263 · Cited by 2,404
Role of angiogenesis in tumor growth and metastasis
FOLKMAN, J. (2002) · Seminars in Oncology · doi:10.1016/s0093-7754(02)70065-1 · Cited by 2,400
Katayama, H., Yamaguchi, K., Kozuka, T., Takashima, T., Seez, P., & Matsuura, K. (1990) · Radiology · doi:10.1148/radiology.175.3.2343107 · Cited by 1,474
The blood supply of neoplasms in the liver.
Breedis, C., & Young, G. P. (1954) · PubMed · Cited by 1,455
The role of angiogenesis in tumor growth.
Folkman, J. (1992) · PubMed · Cited by 1,259
Cammà, C., Schepis, F., Orlando, A., Albanese, M., Shahied, L., Trevisani, F., Andreone, P., Craxì, A., & Cottone, M. (2002) · Radiology · doi:10.1148/radiol.2241011262 · Cited by 851
Cerebral blood flow determination by rapid-sequence computed tomography: theoretical analysis.
Axel, L. (1980) · Radiology · doi:10.1148/radiology.137.3.7003648 · Cited by 625
A Survey of Liver Transplantation from Living Adult Donors in the United States
Brown, R. S., Russo, M. W., Lai, M., Shiffman, M. L., Richardson, M. C., Everhart, J. E., & Hoofnagle, J. H. (2003) · New England Journal of Medicine · doi:10.1056/nejmsa021345 · Cited by 480
Cited by
Liver Cirrhosis: Intravoxel Incoherent Motion MR Imaging—Pilot Study
Luciani, A., Vignaud, A., Cavet, M., Tran Van Nhieu, J., Mallat, A., Ruel, L., Laurent, A., Deux, J.-F., Brugieres, P., & Rahmouni, A. (2008) · Radiology · doi:10.1148/radiol.2493080080 · Cited by 612
Classic models for dynamic contrast‐enhanced MRI
Sourbron, S. P., & Buckley, D. L. (2013) · NMR in Biomedicine · doi:10.1002/nbm.2940 · Cited by 434
Liver regeneration — mechanisms and models to clinical application
Forbes, S. J., & Newsome, P. N. (2016) · Nature Reviews Gastroenterology & Hepatology · doi:10.1038/nrgastro.2016.97 · Cited by 411
Perfusion Magnetic Resonance Imaging: A Comprehensive Update on Principles and Techniques
Jahng, G.-H., Li, K.-L., Ostergaard, L., & Calamante, F. (2014) · Korean Journal of Radiology · doi:10.3348/kjr.2014.15.5.554 · Cited by 256
Miles, K. A., Ganeshan, B., Griffiths, M. R., Young, R. C. D., & Chatwin, C. R. (2009) · Radiology · doi:10.1148/radiol.2502071879 · Cited by 253
Advanced Liver Fibrosis: Diagnosis with 3D Whole-Liver Perfusion MR Imaging—Initial Experience
Hagiwara, M., Rusinek, H., Lee, V. S., Losada, M., Bannan, M. A., Krinsky, G. A., & Taouli, B. (2008) · Radiology · doi:10.1148/radiol.2463070077 · Cited by 227
Self-citationCT Perfusion of the Liver: Principles and Applications in Oncology
Kim, S. H., Kamaya, A., & Willmann, J. K. (2014) · Radiology · doi:10.1148/radiol.14130091 · Cited by 200
Vandecaveye, V., De Keyzer, F., Verslype, C., Op de Beeck, K., Komuta, M., Topal, B., Roebben, I., Bielen, D., Roskams, T., Nevens, F., et al. (2009) · European Radiology · doi:10.1007/s00330-009-1431-5 · Cited by 181
Review of Photoacoustic Flow Imaging: Its Current State and Its Promises
van den Berg, P. J., Daoudi, K., & Steenbergen, W. (2015) · Photoacoustics · doi:10.1016/j.pacs.2015.08.001 · Cited by 84
Metadata
- Authors
- Pandharipande, P. V., Krinsky, G. A., Rusinek, H., & Lee, V. S.
- Venue
- Radiology
- Published
- 2005-03
- Volume
- 234
- Issue
- 3
- Pages
- 661-673
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2119645854
- Cited by
- 294
- References
- 52
- FWCI
- 9.68
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.