The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Coronary Calcium Measurements: Effect of CT Scanner Type and Calcium Measure on Rescan Reproducibility—MESA Study
Abstract
PURPOSE: To evaluate the effect of scanner type and calcium measure on the reproducibility of calcium measurements. MATERIALS AND METHODS: This investigation was approved by the institutional review boards of each study site and by the Institutional Review Board of the Los Angeles Biomedical Research Institute. Informed consent for scanning and participation was obtained from all participants. The study was Health Insurance Portability and Accountability Act compliant. The Multi-Ethnic Study of Atherosclerosis (MESA) is a multicenter observational study of 6814 participants undergoing demographic, risk factor, and subclinical disease evaluations. Coronary artery calcium was measured by using duplicate CT scans. Three study centers used electron-beam computed tomography (CT), and three used multi-detector row CT. Coronary artery calcium was detected in 3355 participants. Three calcium measurement methods-Agatston score, calcium volume, and interpolated volume score-were evaluated. Mean absolute differences between calcium measures on scans 1 and 2, excluding cases for which both scans had a measure of zero, was modeled by using linear regression to compare reproducibility between scanner types. A repeated measures analysis of variance test was used to compare reproducibility across calcium measures, with mean percentage absolute difference as the outcome measure. Rescan reproducibility in relation to misregistrations, noise, and motion artifacts was also examined. Variables were log transformed to create a more normal distribution. RESULTS: Concordance for presence of calcium between duplicate scans was high and similar for both electron-beam and multi-detector row CT (96%, kappa = 0.92). Mean absolute difference between calcium scores for the two scans was 15.8 for electron-beam and 16.9 for multi-detector row CT scanners (P = .06). Mean relative differences were 20.1 for Agatston score, 18.3 for calcium volume, and 18.3 for interpolated volume score (P < .01). Reproducibility was lower for scans with versus those without image misregistrations or motion artifacts (P < .01 for both). CONCLUSION: Electron-beam and multi-detector row CT scanners have equivalent reproducibility for measuring coronary artery calcium. Calcium volumes and interpolated volume scores are slightly more reproducible than Agatston scores. Reproducibility is lower for scans with misregistrations or motion artifacts.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Quantification of coronary artery calcium using ultrafast computed tomography
Agatston, A. S., Janowitz, W. R., Hildner, F. J., Zusmer, N. R., Viamonte, M., & Detrano, R. (1990) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(90)90282-t · Cited by 7,786
Self-citationMulti-Ethnic Study of Atherosclerosis: Objectives and Design
Bild, D. E. (2002) · American Journal of Epidemiology · doi:10.1093/aje/kwf113 · Cited by 3,942
Self-citationGreenland, P. (2004) · JAMA · doi:10.1001/jama.291.2.210 · Cited by 1,829
Carr, J. J., Nelson, J. C., Wong, N. D., McNitt-Gray, M., Arad, Y., Jacobs, D. R., Sidney, S., Bild, D. E., Williams, O. D., & Detrano, R. C. (2005) · Radiology · doi:10.1148/radiol.2341040439 · Cited by 853
Self-citationCallister, T. Q., Cooil, B., Raya, S. P., Lippolis, N. J., Russo, D. J., & Raggi, P. (1998) · Radiology · doi:10.1148/radiology.208.3.9722864 · Cited by 750
AAPM/RSNA Physics Tutorial for Residents: Topics in CT: Radiation Dose in CT
McNitt-Gray, M. F. (2002) · RadioGraphics · doi:10.1148/rg.226025128 · Cited by 612
Self-citationCarr, J. J., Crouse, J. R., Goff, D. C., D'Agostino, R. B., Peterson, N. P., & Burke, G. L. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.174.4.1740915 · Cited by 236
Self-citationPark, R., Detrano, R., Xiang, M., Fu, P., Ibrahim, Y., LaBree, L., & Azen, S. (2002) · Circulation · doi:10.1161/01.cir.0000033819.29662.09 · Cited by 224
Self-citation
Cited by
McClelland, R. L., Chung, H., Detrano, R., Post, W., & Kronmal, R. A. (2006) · Circulation · doi:10.1161/circulationaha.105.580696 · Cited by 885
Self-citationEstrogen Therapy and Coronary-Artery Calcification
Manson, J. E., Allison, M. A., Rossouw, J. E., Carr, J. J., Langer, R. D., Hsia, J., Kuller, L. H., Cochrane, B. B., Hunt, J. R., Ludlam, S. E., et al. (2007) · New England Journal of Medicine · doi:10.1056/nejmoa071513 · Cited by 711
Self-citationCalcium Density of Coronary Artery Plaque and Risk of Incident Cardiovascular Events
Criqui, M. H., Denenberg, J. O., Ix, J. H., McClelland, R. L., Wassel, C. L., Rifkin, D. E., Carr, J. J., Budoff, M. J., & Allison, M. A. (2014) · JAMA · doi:10.1001/jama.2013.282535 · Cited by 642
Self-citationCarr, J. J., Jacobs, D. R., Terry, J. G., Shay, C. M., Sidney, S., Liu, K., Schreiner, P. J., Lewis, C. E., Shikany, J. M., Reis, J. P., et al. (2017) · JAMA Cardiology · doi:10.1001/jamacardio.2016.5493 · Cited by 356
Self-citationBlood Pressure Trajectories in Early Adulthood and Subclinical Atherosclerosis in Middle Age
Allen, N. B., Siddique, J., Wilkins, J. T., Shay, C., Lewis, C. E., Goff, D. C., Jacobs, D. R., Liu, K., & Lloyd-Jones, D. (2014) · JAMA · doi:10.1001/jama.2013.285122 · Cited by 345
Metadata
- Authors
- Detrano, R. C., Anderson, M., Nelson, J., Wong, N. D., Carr, J. J., McNitt-Gray, M., & Bild, D. E.
- Venue
- Radiology
- Published
- 2005-08
- Volume
- 236
- Issue
- 2
- Pages
- 477-484
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2130289472
- Cited by
- 298
- References
- 20
- FWCI
- 15.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coronary Calcium Measurements: Effect of CT Scanner Type and Calcium Measure on Rescan Reproducibility—MESA Study. https://app.cochat.ai/papers/10.1148/radiol.2362040513
- The paper
- Detrano, R. C., Anderson, M., Nelson, J., Wong, N. D., Carr, J. J., McNitt-Gray, M., & Bild, D. E. (2005). Coronary Calcium Measurements: Effect of CT Scanner Type and Calcium Measure on Rescan Reproducibility—MESA Study. Radiology. https://doi.org/10.1148/radiol.2362040513
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.