Hepatic Fat Fraction: MR Imaging for Quantitative Measurement and Display—Early Experience
The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.
Abstract
UNLABELLED: The institutional review board approved this HIPAA-compliant study. After all five patients with nonalcoholic fatty liver disease signed a consent, they underwent magnetic resonance (MR) imaging for hepatic fat quantification. The purpose of this study was to develop a fast and accurate method to acquire and display quantitative maps of the percentage of hepatic fat. In-phase and out-of-phase gradient-echo MR imaging was performed with dual flip angles (70 degrees, 20 degrees) to resolve ambiguity of the dominant constituent. T2* corrections were also estimated and applied to generate color-coded maps of the estimated percentage of hepatic fat. MR imaging results were compared with biopsy results in two of five patients, and the technique was validated qualitatively and quantitatively with a water-oil phantom. Results of the phantom study confirmed that the dual-flip angle algorithm can be used to correctly identify the dominant constituent, allowing depiction of 0%-100% of fat content. The estimated liver fat fraction was comparable to quantitative fat measurements at biopsy in both patients (MR imaging, 18.3% +/- 2.8 [standard deviation] and 28.6% +/- 2.4, vs quantitative histopathologic analysis, 11.2% and 28.5%, respectively). SUPPLEMENTAL MATERIAL: radiology.rsnajnls.org/cgi/content/full/2373041639/DC1
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Nonalcoholic Steatohepatitis: A Proposal for Grading and Staging The Histological Lesions
Brunt, E. M., Janney, C. G., Di Bisceglie, A. M., Neuschwander-Tetri, B. A., & Bacon, B. R. (1999) · American Journal of Gastroenterology · doi:10.1111/j.1572-0241.1999.01377.x · Cited by 3,907
Nonalcoholic fatty liver disease: a spectrum of clinical and pathological severity.
MATTEONI, C., YOUNOSSI, Z., GRAMLICH, T., BOPARAI, N., LIU, Y., & MCCULLOUGH, A. (1999) · Gastroenterology · doi:10.1016/s0016-5085(99)70506-8 · Cited by 3,345
Simple proton spectroscopic imaging.
Dixon, W. T. (1984) · Radiology · doi:10.1148/radiology.153.1.6089263 · Cited by 2,276
The utility of radiological imaging in nonalcoholic fatty liver disease
Saadeh, S., Younossi, Z. M., Remer, E. M., Gramlich, T., Ong, J. P., Hurley, M., Mullen, K. D., Cooper, J. N., & Sheridan, M. J. (2002) · Gastroenterology · doi:10.1053/gast.2002.35354 · Cited by 2,110
Bravo, A. A., Sheth, S. G., & Chopra, S. (2001) · New England Journal of Medicine · doi:10.1056/nejm200102153440706 · Cited by 2,041
Bugianesi, E., Leone, N., Vanni, E., Marchesini, G., Brunello, F., Carucci, P., Musso, A., De Paolis, P., Capussotti, L., Salizzoni, M., et al. (2002) · Gastroenterology · doi:10.1053/gast.2002.34168 · Cited by 1,439
Cryptogenic Cirrhosis: Clinical Characterization and Risk Factors for Underlying Disease
Caldwell, S. H., Oelsner, D. H., Iezzoni, J. C., Hespenheide, E. E., Battle, E. H., & Driscoll, C. J. (1999) · Hepatology · doi:10.1002/hep.510290347 · Cited by 1,143
Three‐point dixon technique for true water/fat decomposition with B0 inhomogeneity correction
Glover, G. H., & Schneider, E. (1991) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910180211 · Cited by 687
Clinical Features and Natural History of Nonalcoholic Steatosis Syndromes
Falck-Ytter, Y., Younossi, Z. M., Marchesini, G., & McCullough, A. J. (2001) · Seminars in Liver Disease · doi:10.1055/s-2001-12926 · Cited by 673
Marrero, J. A., Fontana, R. J., Su, G. L., Conjeevaram, H. S., Emick, D. M., & Lok, A. S. (2002) · Hepatology · doi:10.1002/hep.1840360609 · Cited by 660
Self-citation
Cited by
Klöting, N., Fasshauer, M., Dietrich, A., Kovacs, P., Schön, M. R., Kern, M., Stumvoll, M., & Blüher, M. (2010) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00586.2009 · Cited by 856
“In a post hoc analysis of 47 individuals with previous MRI scans, T1-weighted MRI images were used to estimate liver fat content, as described previously (17).”
MethodQuantitative assessment of liver fat with magnetic resonance imaging and spectroscopy
Reeder, S. B., Cruite, I., Hamilton, G., & Sirlin, C. B. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22580 · Cited by 822
Imajo, K., Kessoku, T., Honda, Y., Tomeno, W., Ogawa, Y., Mawatari, H., Fujita, K., Yoneda, M., Taguri, M., Hyogo, H., et al. (2016) · Gastroenterology · doi:10.1053/j.gastro.2015.11.048 · Cited by 812
Schwenzer, N. F., Springer, F., Schraml, C., Stefan, N., Machann, J., & Schick, F. (2009) · Journal of Hepatology · doi:10.1016/j.jhep.2009.05.023 · Cited by 749
Yu, H., Shimakawa, A., McKenzie, C. A., Brodsky, E., Brittain, J. H., & Reeder, S. B. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21737 · Cited by 694
Tang, A., Tan, J., Sun, M., Hamilton, G., Bydder, M., Wolfson, T., Gamst, A. C., Middleton, M., Brunt, E. M., Loomba, R., et al. (2013) · Radiology · doi:10.1148/radiol.12120896 · Cited by 528
Proton density fat‐fraction: A standardized mr‐based biomarker of tissue fat concentration
Reeder, S. B., Hu, H. H., & Sirlin, C. B. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23741 · Cited by 501
Schwimmer, J. B., Dunn, W., Norman, G. J., Pardee, P. E., Middleton, M. S., Kerkar, N., & Sirlin, C. B. (2010) · Gastroenterology · doi:10.1053/j.gastro.2009.12.052 · Cited by 498
Fat quantification with IDEAL gradient echo imaging: Correction of bias from T1 and noise
Liu, C., McKenzie, C. A., Yu, H., Brittain, J. H., & Reeder, S. B. (2007) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21301 · Cited by 477
Heritability of Nonalcoholic Fatty Liver Disease
Schwimmer, J. B., Celedon, M. A., Lavine, J. E., Salem, R., Campbell, N., Schork, N. J., Shiehmorteza, M., Yokoo, T., Chavez, A., Middleton, M. S., et al. (2009) · Gastroenterology · doi:10.1053/j.gastro.2009.01.050 · Cited by 466
Multiecho reconstruction for simultaneous water‐fat decomposition and T2* estimation
Yu, H., McKenzie, C. A., Shimakawa, A., Vu, A. T., Brau, A. C. S., Beatty, P. J., Pineda, A. R., Brittain, J. H., & Reeder, S. B. (2007) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21090 · Cited by 437
Fatty Liver: Imaging Patterns and Pitfalls
Hamer, O. W., Aguirre, D. A., Casola, G., Lavine, J. E., Woenckhaus, M., & Sirlin, C. B. (2006) · RadioGraphics · doi:10.1148/rg.266065004 · Cited by 433
Chen, J., Talwalkar, J. A., Yin, M., Glaser, K. J., Sanderson, S. O., & Ehman, R. L. (2011) · Radiology · doi:10.1148/radiol.11101942 · Cited by 432
Relaxation effects in the quantification of fat using gradient echo imaging
Bydder, M., Yokoo, T., Hamilton, G., Middleton, M. S., Chavez, A. D., Schwimmer, J. B., Lavine, J. E., & Sirlin, C. B. (2008) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2007.08.012 · Cited by 394
Hepatic Steatosis: Quantification by Proton Density Fat Fraction with MR Imaging versus Liver Biopsy
Idilman, I. S., Aniktar, H., Idilman, R., Kabacam, G., Savas, B., Elhan, A., Celik, A., Bahar, K., & Karcaaltincaba, M. (2013) · Radiology · doi:10.1148/radiol.13121360 · Cited by 389
Lee, S. S., Park, S. H., Kim, H. J., Kim, S. Y., Kim, M.-Y., Kim, D. Y., Suh, D. J., Kim, K. M., Bae, M. H., Lee, J. Y., et al. (2010) · Journal of Hepatology · doi:10.1016/j.jhep.2010.01.008 · Cited by 372
Quantification of Liver Fat with Magnetic Resonance Imaging
Reeder, S. B., & Sirlin, C. B. (2010) · Magnetic Resonance Imaging Clinics of North America · doi:10.1016/j.mric.2010.08.013 · Cited by 342
Imaging-based Quantification of Hepatic Fat: Methods and Clinical Applications
Ma, X., Holalkere, N.-S., R, A. K., Mino-Kenudson, M., Hahn, P. F., & Sahani, D. V. (2009) · RadioGraphics · doi:10.1148/rg.295085186 · Cited by 312
Yokoo, T., Bydder, M., Hamilton, G., Middleton, M. S., Gamst, A. C., Wolfson, T., Hassanein, T., Patton, H. M., Lavine, J. E., Schwimmer, J. B., et al. (2009) · Radiology · doi:10.1148/radiol.2511080666 · Cited by 303
Estimation of Hepatic Proton-Density Fat Fraction by Using MR Imaging at 3.0 T
Yokoo, T., Shiehmorteza, M., Hamilton, G., Wolfson, T., Schroeder, M. E., Middleton, M. S., Bydder, M., Gamst, A. C., Kono, Y., Kuo, A., et al. (2011) · Radiology · doi:10.1148/radiol.10100659 · Cited by 290
Fatty Liver Disease: MR Imaging Techniques for the Detection and Quantification of Liver Steatosis
Cassidy, F. H., Yokoo, T., Aganovic, L., Hanna, R. F., Bydder, M., Middleton, M. S., Hamilton, G., Chavez, A. D., Schwimmer, J. B., & Sirlin, C. B. (2009) · RadioGraphics · doi:10.1148/rg.291075123 · Cited by 271
Non-invasive means of measuring hepatic fat content
Mehta, S. R., Thomas, E. L., Bell, J. D., Johnston, D. G., & Taylor-Robinson, S. D. (2008) · World Journal of Gastroenterology · doi:10.3748/wjg.14.3476 · Cited by 255
Quantification of hepatic steatosis with MRI: The effects of accurate fat spectral modeling
Reeder, S. B., Robson, P. M., Yu, H., Shimakawa, A., Hines, C. D., McKenzie, C. A., & Brittain, J. H. (2009) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21751 · Cited by 248
Liver fat quantification using a multi‐step adaptive fitting approach with multi‐echo GRE imaging
Zhong, X., Nickel, M. D., Kannengiesser, S. A. R., Dale, B. M., Kiefer, B., & Bashir, M. R. (2014) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25054 · Cited by 216
Hines, C. D. G., Frydrychowicz, A., Hamilton, G., Tudorascu, D. L., Vigen, K. K., Yu, H., McKenzie, C. A., Sirlin, C. B., Brittain, J. H., & Reeder, S. B. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22514 · Cited by 201
Advanced MRI Methods for Assessment of Chronic Liver Disease
Taouli, B., Ehman, R. L., & Reeder, S. B. (2009) · American Journal of Roentgenology · doi:10.2214/ajr.09.2601 · Cited by 197
Nonalcoholic fatty liver disease
Erickson, S. K. (2009) · Journal of Lipid Research · doi:10.1194/jlr.r800089-jlr200 · Cited by 194
Magnetic resonance imaging and spectroscopy for monitoring liver steatosis
Cowin, G. J., Jonsson, J. R., Bauer, J. D., Ash, S., Ali, A., Osland, E. J., Purdie, D. M., Clouston, A. D., Powell, E. E., & Galloway, G. J. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21542 · Cited by 191
“This was addressed recently for IP/OP imaging by Hussain et al (33) by using dual pulse angles, which removed this ambiguity at high fat levels.”
BackgroundYu, H., Shimakawa, A., Hines, C. D. G., McKenzie, C. A., Hamilton, G., Sirlin, C. B., Brittain, J. H., & Reeder, S. B. (2011) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22840 · Cited by 190
“Additional information can be used to help the identification of water and fat, such as using low resolution spectroscopy (15) and difference in T1 (3,16) or T2* relaxation parameters (17), which require either additional data or a more complex model.”
BackgroundKang, G. H., Cruite, I., Shiehmorteza, M., Wolfson, T., Gamst, A. C., Hamilton, G., Bydder, M., Middleton, M. S., & Sirlin, C. B. (2011) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.22701 · Cited by 158
“These techniques use low flip angle (relative to repetition time) to minimize T1 bias (16,19,20), acquire multiple echoes per excitation to permit correction for T2* effects (9,19,21), and address the multifrequency interference effects of fat (9,10).”
MethodLiver Fat Quantification by Dual-echo MR Imaging Outperforms Traditional Histopathological Analysis
Fischer, M. A., Raptis, D. A., Montani, M., Graf, R., Clavien, P.-A., Nanz, D., Alkadhi, H., & Scheffel, H. (2012) · Academic Radiology · doi:10.1016/j.acra.2012.05.009 · Cited by 25
Metadata
- Authors
- Hussain, H. K., Chenevert, T. L., Londy, F. J., Gulani, V., Swanson, S. D., McKenna, B. J., Appelman, H. D., Adusumilli, S., Greenson, J. K., & Conjeevaram, H. S.
- Venue
- Radiology
- Published
- 2005-12
- Volume
- 237
- Issue
- 3
- Pages
- 1048-1055
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2133671942
- Cited by
- 277
- References
- 42
- FWCI
- 8.51
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.