CT Angiography of Pulmonary Arteries to Detect Pulmonary Embolism: Improvement of Vascular Enhancement with Low Kilovoltage Settings
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
PURPOSE: To retrospectively compare a low kilovoltage scanning protocol with a reduced radiation dose with a standard high kilovoltage, moderate-dose protocol for the depiction of central and peripheral pulmonary arteries at single-detector spiral computed tomography (CT). MATERIALS AND METHODS: This retrospective study had institutional review board approval; informed consent was waived. A 100-kVp protocol (volume CT dose index [CTDI(vol)], 3.4 mGy) was compared with a standard 140-kVp protocol (CTDI(vol), 10.4 mGy) in two groups that were each composed of 35 consecutive patients who were suspected of having pulmonary embolism (PE) and scanned with otherwise identical acquisition parameters and contrast material injection protocols. Mean main pulmonary artery enhancement and maximum enhancement in peripheral pulmonary arteries were compared. In a blinded evaluation, the percentages of segmental and subsegmental arteries that were considered analyzable for assessment of PE were determined. Overall image quality and delineation of various anatomic areas were subjectively assessed. Comparison of percentages of analyzable segmental and subsegmental arteries and subjective grading of image quality between the two different protocols were performed with the Mann-Whitney U test. RESULTS: There were 38 male and 24 female patients (mean age, 61 years; range, 17-86 years) in the final evaluation. There was a significantly higher average CT number in the main pulmonary artery (379 HU +/- 95) for the 100-kVp protocol than for the 140-kVp protocol (268 HU +/- 63, P < .001, two-sided t test). Maximum CT numbers in peripheral pulmonary arteries at the level of the aortic arch and lung bases, respectively, were 290 HU +/- 91 and 279 HU +/- 100 for 100 kVp and 185 HU +/- 65 and 144 HU +/- 63 for 140 kVp (P < .001). Mean percentage of subsegmental arteries considered analyzable per patient was higher for 100 kVp than for 140 kVp (segmental arteries, 92% vs 88%, P = .13; subsegmental arteries, 71% vs 55%, P < .001). Subjective grading of overall image quality and of the delineation of structures in the lungs, mediastinum, and upper abdomen did not significantly differ between protocols. CONCLUSION: At reduced radiation exposure, low kilovoltage scanning increases the percentage of central and peripheral pulmonary arteries that can be evaluated with CT angiography without a substantial decrease in image quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
AAPM/RSNA Physics Tutorial for Residents: Topics in CT: Radiation Dose in CT
McNitt-Gray, M. F. (2002) · RadioGraphics · doi:10.1148/rg.226025128 · Cited by 612
Four Multidetector-Row Helical CT: Image Quality and Volume Coverage Speed
Hu, H., He, H. D., Foley, W. D., & Fox, S. H. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap3755 · Cited by 509
Performance evaluation of a multi-slice CT system
McCollough, C. H., & Zink, F. E. (1999) · Medical Physics · doi:10.1118/1.598777 · Cited by 386
Sigal-Cinqualbre, A. B., Hennequin, R., Abada, H. T., Chen, X., & Paul, J.-F. (2004) · Radiology · doi:10.1148/radiol.2311030191 · Cited by 372
Peripheral Pulmonary Arteries: How Far in the Lung Does Multi-Detector Row Spiral CT Allow Analysis?
Ghaye, B., Szapiro, D., Mastora, I., Delannoy, V., Duhamel, A., Remy, J., & Remy-Jardin, M. (2001) · Radiology · doi:10.1148/radiology.219.3.r01jn32629 · Cited by 344
Pulmonary Embolism: Optimization of Small Pulmonary Artery Visualization at Multi–Detector Row CT
Patel, S., Kazerooni, E. A., & Cascade, P. N. (2003) · Radiology · doi:10.1148/radiol.2272011139 · Cited by 274
Using 80 kVp versus 120 kVp in perfusion CT measurement of regional cerebral blood flow.
Wintermark, M., Maeder, P. P., Verdun, F. R., Thiran, J., Valley, J., Schnyder, P. A., & Meuli, R. A. (2000) · PubMed · Cited by 269
Peripheral pulmonary arteries: optimization of the spiral CT acquisition protocol.
Remy-Jardin, M., Remy, J., Artaud, D., Deschildre, F., & Duhamel, A. (1997) · Radiology · doi:10.1148/radiology.204.1.9205239 · Cited by 208
Fricke, B. L., Donnelly, L. F., Frush, D. P., Yoshizumi, T., Varchena, V., Poe, S. A., & Lucaya, J. (2003) · American Journal of Roentgenology · doi:10.2214/ajr.180.2.1800407 · Cited by 183
Cited by
Marin, D., Nelson, R. C., Schindera, S. T., Richard, S., Youngblood, R. S., Yoshizumi, T. T., & Samei, E. (2010) · Radiology · doi:10.1148/radiol.09090094 · Cited by 484
Radiation dose reduction in computed tomography: techniques and future perspective
Yu, L., Liu, X., Leng, S., Kofler, J. M., Ramirez-Giraldo, J. C., Qu, M., Christner, J., Fletcher, J. G., & McCollough, C. H. (2009) · Imaging in Medicine · doi:10.2217/iim.09.5 · Cited by 395
Radiation Dose Reduction in Chest CT: A Review
Kubo, T., Lin, P.-J. P., Stiller, W., Takahashi, M., Kauczor, H.-U., Ohno, Y., & Hatabu, H. (2008) · American Journal of Roentgenology · doi:10.2214/ajr.07.2556 · Cited by 256
Lung Perfusion with Dual-energy Multidetector-row CT (MDCT)
Pontana, F., Faivre, J.-B., Remy-Jardin, M., Flohr, T., Schmidt, B., Tacelli, N., Pansini, V., & Remy, J. (2008) · Academic Radiology · doi:10.1016/j.acra.2008.05.018 · Cited by 233
Application‐ and patient size‐dependent optimization of x‐ray spectra for CT
Kalender, W. A., Deak, P., Kellermeier, M., van Straten, M., & Vollmar, S. V. (2009) · Medical Physics · doi:10.1118/1.3075901 · Cited by 206
Computed tomography in paediatric heart disease
Mortensen, K. H., & Tann, O. (2018) · The British Journal of Radiology · doi:10.1259/bjr.20180201 · Cited by 24
Metadata
- Authors
- Schueller-Weidekamm, C., Schaefer-Prokop, C. M., Weber, M., Herold, C. J., & Prokop, M.
- Venue
- Radiology
- Published
- 2006-12
- Volume
- 241
- Issue
- 3
- Pages
- 899-907
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2141773937
- Cited by
- 258
- References
- 11
- FWCI
- 8.56
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.