The Current Status of Breast MR Imaging Part I. Choice of Technique, Image Interpretation, Diagnostic Accuracy, and Transfer to Clinical Practice
The DOI matches its Crossref record; 44 of the 44 references it cites were found in a registry or an index.
Abstract
Compared with mammography and breast ultrasonography, contrast material-enhanced magnetic resonance (MR) imaging is a breast imaging technique that offers not only information on lesion cross-sectional morphology but also on functional lesion features such as tissue perfusion and enhancement kinetics. After an enthusiastic start to clinical breast MR imaging in the early 1990s, a variety of difficulties and obstacles were identified that hampered the transfer of the modality into clinical practice, including a lack of standardization regarding image acquisition and interpretation guidelines, a lack of MR-compatible interventional materials, and a lack of evidence regarding its diagnostic accuracy--particularly specificity and positive predictive value, as well as sensitivity for ductal carcinoma in situ. This article is the first of two on the current status of breast MR imaging. The pathophysiologic basis of breast MR and the effects on acquisition technique and diagnostic accuracy, the diverging demands of high spatial and temporal resolution, and the different approaches that exist for image acquisition are reviewed. Advantages and disadvantages of different pulse sequence parameters are discussed to help radiologists make a balanced and informed decision regarding choice of image acquisition protocol. Imaging findings in common benign and malignant changes are described, and current concepts for differential diagnosis, including the MR Breast Imaging Reporting and Data System lexicon, are discussed. Furthermore, obstacles that impeded the technique's transfer into clinical practice are discussed, and the progress made in recent years, especially regarding the development of guidelines, procedural standardization, and MR-guided interventions are outlined.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Folkman, J., & Klagsbrun, M. (1987) · Science · doi:10.1126/science.2432664 · Cited by 3,491
Tofts, P. S., Brix, G., Buckley, D. L., Evelhoch, J. L., Henderson, E., Knopp, M. V., Larsson, H. B. W., Lee, T.-Y., Mayr, N. A., Parker, G. J. M., et al. (1999) · Journal of Magnetic Resonance Imaging · doi:10.1002/(sici)1522-2586(199909)10:3<223::aid-jmri2>3.0.co;2-s · Cited by 3,143
Induction of angiogenesis during the transition from hyperplasia to neoplasia
Folkman, J., Watson, K., Ingber, D., & Hanahan, D. (1989) · Nature · doi:10.1038/339058a0 · Cited by 1,879
Berg, W. A., Gutierrez, L., NessAiver, M. S., Carter, W. B., Bhargavan, M., Lewis, R. S., & Ioffe, O. B. (2004) · Radiology · doi:10.1148/radiol.2333031484 · Cited by 1,439
Kuhl, C. K., Mielcareck, P., Klaschik, S., Leutner, C., Wardelmann, E., Gieseke, J., & Schild, H. H. (1999) · Radiology · doi:10.1148/radiology.211.1.r99ap38101 · Cited by 1,277
Self-citationMR Imaging of the Breast for the Detection, Diagnosis, and Staging of Breast Cancer
Orel, S. G., & Schnall, M. D. (2001) · Radiology · doi:10.1148/radiology.220.1.r01jl3113 · Cited by 759
Breast Carcinoma: Effect of Preoperative Contrast-enhanced MR Imaging on the Therapeutic Approach
Fischer, U., Kopka, L., & Grabbe, E. (1999) · Radiology · doi:10.1148/radiology.213.3.r99dc01881 · Cited by 664
Harms, S. E., Flamig, D. P., Hesley, K. L., Meiches, M. D., Jensen, R. A., Evans, W. P., Savino, D. A., & Wells, R. V. (1993) · Radiology · doi:10.1148/radiology.187.2.8475297 · Cited by 634
Avril, N., Rosé, C. A., Schelling, M., Dose, J., Kuhn, W., Bense, S., Weber, W., Ziegler, S., Graeff, H., & Schwaiger, M. (2000) · Journal of Clinical Oncology · doi:10.1200/jco.2000.18.20.3495 · Cited by 557
Kuhl, C. K., Schmutzler, R. K., Leutner, C. C., Kempe, A., Wardelmann, E., Hocke, A., Maringa, M., Pfeifer, U., Krebs, D., & Schild, H. H. (2000) · Radiology · doi:10.1148/radiology.215.1.r00ap01267 · Cited by 538
Self-citation
Cited by
Magnetic resonance imaging of the breast: Recommendations from the EUSOMA working group
Sardanelli, F., Boetes, C., Borisch, B., Decker, T., Federico, M., Gilbert, F. J., Helbich, T., Heywang-Köbrunner, S. H., Kaiser, W. A., Kerin, M. J., et al. (2010) · European Journal of Cancer · doi:10.1016/j.ejca.2010.02.015 · Cited by 992
Applications and potential toxicity of magnetic iron oxide nanoparticles
Liu, G., Gao, J., Ai, H., & Chen, X. (2013) · Small · doi:10.1002/smll.201201531 · Cited by 570
25 Years of Contrast-Enhanced MRI: Developments, Current Challenges and Future Perspectives
Lohrke, J., Frenzel, T., Endrikat, J., Alves, F. C., Grist, T. M., Law, M., Lee, J. M., Leiner, T., Li, K.-C., Nikolaou, K., et al. (2016) · Advances in Therapy · doi:10.1007/s12325-015-0275-4 · Cited by 420
Current Status of Breast MR Imaging Part 2. Clinical Applications
Kuhl, C. K. (2007) · Radiology · doi:10.1148/radiol.2443051661 · Cited by 377
Self-citationContrast-enhanced Mammography: State of the Art
Jochelson, M. S., & Lobbes, M. B. I. (2021) · Radiology · doi:10.1148/radiol.2021201948 · Cited by 352
The ACR BI-RADS® Experience: Learning From History
Burnside, E. S., Sickles, E. A., Bassett, L. W., Rubin, D. L., Lee, C. H., Ikeda, D. M., Mendelson, E. B., Wilcox, P. A., Butler, P. F., & D'Orsi, C. J. (2009) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2009.07.023 · Cited by 319
Review of MR elastography applications and recent developments
Glaser, K. J., Manduca, A., & Ehman, R. L. (2012) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.23597 · Cited by 245
Lymph Node Imaging in Patients with Primary Breast Cancer: Concurrent Diagnostic Tools
Marino, M. A., Avendano, D., Zapata, P., Riedl, C. C., & Pinker, K. (2020) · The Oncologist · doi:10.1634/theoncologist.2019-0427 · Cited by 237
Lobbes, M. B. I., Lalji, U., Houwers, J., Nijssen, E. C., Nelemans, P. J., van Roozendaal, L., Smidt, M. L., Heuts, E., & Wildberger, J. E. (2014) · European Radiology · doi:10.1007/s00330-014-3154-5 · Cited by 210
“This makes the vessels permeable to contrast agent, resulting in tumour enhancement [3].”
Mann, R. M., Loo, C. E., Wobbes, T., Bult, P., Barentsz, J. O., Gilhuijs, K. G. A., & Boetes, C. (2010) · Breast Cancer Research and Treatment · doi:10.1007/s10549-009-0616-6 · Cited by 206
“It is therefore impossible to tell whether or not such advantages may result in further benefit for patients [46, 47].”
BackgroundHeijblom, M., Piras, D., Xia, W., van Hespen, J. C. G., Klaase, J. M., van den Engh, F. M., van Leeuwen, T. G., Steenbergen, W., & Manohar, S. (2012) · Optics Express · doi:10.1364/oe.20.011582 · Cited by 199
Comparison between Breast MRI and Contrast-Enhanced Spectral Mammography
Jakubowicz, J. (2015) · Medical Science Monitor · doi:10.12659/msm.893018 · Cited by 173
Image standards in tissue-based diagnosis (diagnostic surgical pathology)
Kayser, K., Görtler, J., Goldmann, T., Vollmer, E., Hufnagl, P., & Kayser, G. (2008) · Diagnostic Pathology · doi:10.1186/1746-1596-3-17 · Cited by 56
“They are tools that have successfully replaced the conventional work flow in live imaging [15,21,17,18].”
BackgroundMethodIdentification of Breast Cancer Using Integrated Information from MRI and Mammography
Yang, S.-N., Li, F.-J., Liao, Y.-H., Chen, Y.-S., Shen, W.-C., & Huang, T.-C. (2015) · PLoS ONE · doi:10.1371/journal.pone.0128404 · Cited by 36
Metadata
- Authors
- Kuhl, C.
- Venue
- Radiology
- Published
- 2007-08
- Volume
- 244
- Issue
- 2
- Pages
- 356-378
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2168140453
- Cited by
- 778
- References
- 44
- FWCI
- 30.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.