A method of comparing the areas under receiver operating characteristic curves derived from the same cases
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Receiver operating characteristic (ROC) curves are used to describe and compare the performance of diagnostic technology and diagnostic algorithms. This paper refines the statistical comparison of the areas under two ROC curves derived from the same set of patients by taking into account the correlation between the areas that is induced by the paired nature of the data. The correspondence between the area under an ROC curve and the Wilcoxon statistic is used and underlying Gaussian distributions (binormal) are assumed to provide a table that converts the observed correlations in paired ratings of images into a correlation between the two ROC areas. This between-area correlation can be used to reduce the standard error (uncertainty) about the observed difference in areas. This correction for pairing, analogous to that used in the paired t-test, can produce a considerable increase in the statistical sensitivity (power) of the comparison. For studies involving multiple readers, this method provides a measure of a component of the sampling variation that is otherwise difficult to obtain.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Changes in bacterial composition have been shown to serve as a primary driver of TMAO levels in other studies (10,15).”
From Prognostic Value of Elevated Levels of Intestinal Microbe-Generated Metabolite Trimethylamine-N-Oxide in Patients With Heart Failure (2014) · cites this paper as [15]
Citations
Cites
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856 · cited 4×
“In a recent paper (4) we dealt with one popular accuracy index that can be derived from and used as a summary of the ROC curve.”
BackgroundMethodInfluentialSelf-citationBasic principles of ROC analysis
Metz, C. E. (1978) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(78)80014-2 · Cited by 6,026
Dorfman, D. D., & Alf, E. (1969) · Journal of Mathematical Psychology · doi:10.1016/0022-2496(69)90019-4 · Cited by 874 · cited 1×
“tamed in three ways: (i) by the trapezoidal rule; (ii) as output from the Dorfman and Alf maximum likelihood estimation program (5); or (iu) from the slope and intercept of the original data when plotted on binormal graph paper (3).”
MethodROC Analysis Applied to the Evaluation of Medical Imaging Techniques
SWETS, J. A. (1979) · Investigative Radiology · doi:10.1097/00004424-197903000-00002 · Cited by 699 · cited 1×
“tamed in three ways: (i) by the trapezoidal rule; (ii) as output from the Dorfman and Alf maximum likelihood estimation program (5); or (iu) from the slope and intercept of the original data when plotted on binormal graph paper (3).”
MethodStatistical significance tests for binormal ROC curves
Metz, C. E., & Kronman, H. B. (1980) · Journal of Mathematical Psychology · doi:10.1016/0022-2496(80)90020-6 · Cited by 175 · cited 1×
“analogous to those used by Pollack and Hsieh (6) and Metz and Kronman (7).”
MethodSampling variability of the area under the ROC-curve and of d'e.
Pollack, I. W., & Hsieh, R. (1969) · Psychological Bulletin · doi:10.1037/h0026862 · Cited by 100
Cited by
Items 801–900 of 1,054
Sjöstedt, G., & Långström, N. (2001) · Law and Human Behavior · doi:10.1023/a:1012758307983 · Cited by 149
“The RRASOR was derived from a meta-analysis conducted by Hanson and Bussière (1998) that, based on a total of 61 studies including almost 29,000 sex offenders, identified seven risk factors associated (Pearson’s r ≥ .”
MethodNatalini, G., Rosanò, A., Taranto, M., Faggian, B., Vittorielli, E., & Bernardini, A. (2006) · Anesthesia & Analgesia · doi:10.1213/01.ane.0000246811.88524.75 · Cited by 136
“The areas under the ROC curves were calculated and compared as previously described (17).”
MethodTimsit, J.-F., Fosse, J.-P., Troché, G., de Lassence, A., Alberti, C., Garrouste-Orgeas, M., Bornstain, C., Adrie, C., Cheval, C., & Chevret, S. (2002) · Critical Care Medicine · doi:10.1097/00003246-200209000-00009 · Cited by 135
Reuter, D. A., Felbinger, T. W., Kilger, E., Schmidt, C., Lamm, P., & Goetz, A. E. (2002) · British Journal of Anaesthesia · doi:10.1093/bja/88.1.124 · Cited by 136
Kempf, T., Sinning, J.-M., Quint, A., Bickel, C., Sinning, C., Wild, P. S., Schnabel, R., Lubos, E., Rupprecht, H. J., Münzel, T., et al. (2009) · Circulation: Cardiovascular Genetics · doi:10.1161/circgenetics.108.824870 · Cited by 131
How Well Can Physicians Estimate Mortality in a Medical Intensive Care Unit?
McClish, D. K., & Powell, S. H. (1989) · Medical Decision Making · doi:10.1177/0272989x8900900207 · Cited by 136
Armengaud, J.-B., Charkaluk, M.-L., Trivin, C., Tardy, V., Bréart, G., Brauner, R., & Chalumeau, M. (2009) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2009-0314 · Cited by 135
“The discriminating power of the potential predictors was evaluated by comparing the areas under receiver-operating characteristic (ROC) curves according to the standard method described by Hanley and McNeil (33).”
MethodStörk, S., Boivin, V., Horf, R., Hein, L., Lohse, M. J., Angermann, C. E., & Jahns, R. (2006) · American Heart Journal · doi:10.1016/j.ahj.2006.05.004 · Cited by 135
“ROC area, taking into account the correlation between models as they were based on the same cases.(19) All P values are”
Hamilton, B. H., Ko, C. Y., Richards, K., & Hall, B. L. (2010) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2009.10.021 · Cited by 135
Kobus, T., Vos, P., Hambrock, T., de Rooij, M., de Kaa, C. A. H., Barentsz, J. O., Heerschap, A., & Scheenen, T. W. J. (2012) · Radiology · doi:10.1148/radiol.12111744 · Cited by 135
Wormith, J. S., Hogg, S. M., & Guzzo, L. (2012) · Criminal Justice and Behavior · doi:10.1177/0093854812455741 · Cited by 140
“Predictive validity was assessed with correlations and ROC curves (Hanley & McNeil, 1983).”
MethodChalmers, J. D., Taylor, J. K., Mandal, P., Choudhury, G., Singanayagam, A., Akram, A. R., & Hill, A. T. (2011) · Clinical Infectious Diseases · doi:10.1093/cid/cir463 · Cited by 134
Prediction of Common Bile Duct Stones by Noninvasive Tests
Prat, F., Meduri, B., Ducot, B., Chiche, R., Salimbeni-Bartolini, R., & Pelletier, G. (1999) · Annals of Surgery · doi:10.1097/00000658-199903000-00009 · Cited by 135
Oddoze, C., Morange, S., Portugal, H., Berland, Y., & Dussol, B. (2001) · American Journal of Kidney Diseases · doi:10.1053/ajkd.2001.26096 · Cited by 135
Kanamori, A., Nakamura, M., Matsui, N., Nagai, A., Nakanishi, Y., Kusuhara, S., Yamada, Y., & Negi, A. (2004) · Ophthalmology · doi:10.1016/j.ophtha.2004.05.035 · Cited by 135
Hourani, R. G., Brant, L. J., Rizk, T., Weingart, J. D., Barker, P. B., & Horská, A. (2007) · American Journal of Neuroradiology · doi:10.3174/ajnr.a0810 · Cited by 134
“We compared the areas under the different curves with each other using the technique proposed by Hanley and McNeil.16 A greater area under the curve indicates a better discriminatory ability of the correspond- ing imaging procedure.”
MethodBeggs, S. M., & Grace, R. C. (2010) · Sexual Abuse · doi:10.1177/1079063210369014 · Cited by 141
“…the VRS:SO pretreatment dynamic scores were more strongly predictive of sexual recidivism than scores based on psychometric self-reports; however, the difference in AUC values (.78 for VRS:SO Dynamic vs. .70 for Overall Deviance) was not statistically significant, z = 1.36 (Hanley & McNeil, 1983).”
MethodInfluentialBao, Y., Ma, X., Li, H., Zhou, M., Hu, C., Wu, H., Tang, J., Hou, X., Xiang, K., & Jia, W. (2010) · BMJ · doi:10.1136/bmj.c2249 · Cited by 134
“and fasting plasma glucose predicting undiagnosed diabetes.”
Merkel, C., Zoli, M., Siringo, S., van Buuren, H., Magalotti, D., Angeli, P., Sacerdoti, D., Bolondi, L., & Gatta, A. (2000) · The American Journal of Gastroenterology · doi:10.1111/j.1572-0241.2000.03204.x · Cited by 134
“The AUC according to Rev-NIEC was calculated and was compared to the AUC obtained according to the original NIEC index, using the method described for the comparison of AUCs obtained from the same data (14).”
MethodEthnic and Sex Bias in Primary Care Screening Tests for Alcohol Use Disorders
Steinbauer, J. R., Cantor, S. B., Holzer III, C. E., & Volk, R. J. (1998) · Annals of Internal Medicine · doi:10.7326/0003-4819-129-5-199809010-00002 · Cited by 134
Monnet, X., Letierce, A., Hamzaoui, O., Chemla, D., Anguel, N., Osman, D., Richard, C., & Teboul, J. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e31820edcf0 · Cited by 133
Nakata, T., Hashimoto, A., Hase, M., Tsuchihashi, K., & Shimamoto, K. (2003) · Cardiology · doi:10.1159/000069726 · Cited by 133
Pisano, E. D., Gatsonis, C. A., Yaffe, M. J., Hendrick, R. E., Tosteson, A. N. A., Fryback, D. G., Bassett, L. W., Baum, J. K., Conant, E. F., Jong, R. A., et al. (2005) · Radiology · doi:10.1148/radiol.2362050440 · Cited by 133
Osnabrugge, R. L., Speir, A. M., Head, S. J., Fonner, C. E., Fonner, E., Kappetein, A. P., & Rich, J. B. (2014) · European Journal of Cardio-Thoracic Surgery · doi:10.1093/ejcts/ezu033 · Cited by 126
“AUCs were compared using the method proposed by Hanley and McNeil [19].”
MethodShapiro, N. I., Trzeciak, S., Hollander, J. E., Birkhahn, R., Otero, R., Osborn, T. M., Moretti, E., Nguyen, H. B., Gunnerson, K. J., MILZMAN, D. P., et al. (2010) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2010.02.010 · Cited by 143
Seo, E. H., Lee, D. Y., Kim, S. G., Kim, K. W., Kim, D. H., Kim, B., Kim, M.-D., Kim, S. Y., Kim, Y. H., Kim, J. L., et al. (2010) · Archives of Gerontology and Geriatrics · doi:10.1016/j.archger.2010.04.008 · Cited by 132
“Areas under the curve (AUC) of ROC curves were compared among the TICS, TICSm and MMSE according to the method suggested by Hanley and McNeil (1983).”
MethodFemale sexual arousal: Genital anatomy and orgasm in intercourse
Wallen, K., & Lloyd, E. A. (2010) · Hormones and Behavior · doi:10.1016/j.yhbeh.2010.12.004 · Cited by 132
“To determine whether CUMD reliably predicts orgasm in inter-course we calculated Receiver Operator Characteristic (ROC) curves, a technique developed for signal detection, but often used to assess the validity of medical diagnoses (Hanley and McNeil, 1982;1983; Zweig Fig.”
MethodScreening for Mild Cognitive Impairment: Comparison of “MCI Specific” Screening Instruments
Ó’Caoimh, R., Timmons, S., & Molloy, D. W. (2016) · Journal of Alzheimer s Disease · doi:10.3233/jad-150881 · Cited by 138
“Accuracy was assessed with receiver operating characteristics (ROC) curves, compared with the Hanley method [47].”
MethodKrasula, L., Fliegel, K., Callet, P. L., & Klima, M. (2016) · International Conference on Quality of Multimedia Experience (QoMEX) · doi:10.1109/qomex.2016.7498936 · Cited by 139
Risch, L., Blumberg, A., & Huber, A. (1999) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/14.8.1991 · Cited by 132
Prediction of Mortality Risk in the Elderly
Störk, S., Feelders, R. A., van den Beld, A. W., Steyerberg, E. W., Savelkoul, H. F. J., Lamberts, S. W. J., Grobbee, D. E., & Bots, M. L. (2006) · The American Journal of Medicine · doi:10.1016/j.amjmed.2005.10.062 · Cited by 141
Fuat, A., Murphy, J. J., Hungin, A. P. S., Curry, J., Mehrzad, A., Hetherington, A., Johnston, J. I., Smellie, W. S. A., Duffy, V., & Cawley, P. (2006) · Durham Research Online (Durham University) · Cited by 168
Coronary calcium and standard risk factors in symptomatic patients referred for coronary angiography
Kennedy, J. M., Shavelle, R. M., Wang, S., Budoff, M. J., & Detrano, R. (1998) · American Heart Journal · doi:10.1016/s0002-8703(98)70288-1 · Cited by 132
Prediction of fluid responsiveness in mechanically ventilated children undergoing neurosurgery
Byon, H., Lim, C.-W., Lee, J.-H., Park, Y.-H., Kim, H.-S., Kim, C. S., & Kim, J. (2012) · British Journal of Anaesthesia · doi:10.1093/bja/aes467 · Cited by 139
Garrouste-Orgeas, M., Montuclard, L., Timsit, J., Misset, B., Christias, M., & Carlet, J. M. (2003) · Intensive Care Medicine · doi:10.1007/s00134-003-1709-z · Cited by 131
“The method of Hanley and McNeil [12] was used to compare ROC-AUC values.”
MethodTu, J. V., Sykora, K., & Naylor, C. D. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00295-7 · Cited by 131
Hatazawa, J., Shimosegawa, E., Toyoshima, H., Ardekani, B. A., Suzuki, A., Okudera, T., & Miura, Y. (1999) · Stroke · doi:10.1161/01.str.30.4.800 · Cited by 131
Diagnostic criteria for carotid duplex sonography
Robinson, M. L., Sacks, D., Perlmutter, G. S., & Marinelli, D. (1988) · American Journal of Roentgenology · doi:10.2214/ajr.151.5.1045 · Cited by 131
Zhuang, Y., Ding, H., Zhang, Y., Sun, H., Xu, C., & Wang, W. (2016) · Radiology · doi:10.1148/radiol.2016160131 · Cited by 130
Suzuki, K., Shiraishi, J., Abé, H., MacMahon, H., & Doi, K. (2005) · Academic Radiology · doi:10.1016/j.acra.2004.11.017 · Cited by 143
“The values of Az, the area under the ROC curve ( 49 ), for the MTANN with use of the background-trend correction with the first-order polynomial and for the MTANN with the second-order polynomial were very similar (both Az 0.75).”
MethodInfluentialArena, R., Myers, J., Abella, J., Pinkstaff, S., Brubaker, P., Moore, B., Kitzman, D., Peberdy, M. A., Bensimhon, D., Chase, P., et al. (2009) · Circulation: Heart Failure · doi:10.1161/circheartfailure.108.834168 · Cited by 123
Validation of probabilistic predictions
Miller, M. E., Langefeld, C. D., Tierney, W. M., Hui, S. L., & McDonald, C. J. (1993) · Medical Decision Making · doi:10.1177/0272989x9301300107 · Cited by 129
Davenport, D. L., Holsapple, C. W., & Conigliaro, J. C. (2009) · American Journal of Medical Quality · doi:10.1177/1062860609339936 · Cited by 132
“012 using the Hanley–McNeil method for testing difference).(29) Both data sets yielded significant models (χ(2) P < .”
MethodKocabaş, E., Sarikçioğlu, A., Aksaray, N., Şeydaoğlu, G., Seyhun, Y., & Yaman, A. (2007) · The Turkish Journal of Pediatrics · doi:10.24953/turkjpediatr.2007.2503 · Cited by 129
A new integrative weaning index of discontinuation from mechanical ventilation
Nemer, S. N., Barbas, C. S. V., Caldeira, J. B., Cárias, T. C., Santos, R. G., Almeida, L. C., de Azeredo, L. M., Noé, R., Guimarães, B. S., & Souza, P. C. P. (2009) · Critical Care · doi:10.1186/cc8051 · Cited by 152
“The area under the ROC curves for each index was calculated by the nonparametric method of Hanley and McNeil [19] and compared through a technique IWI Cst rs SaO f Vt= ×, / ( / )2 Page 3 of 9 (page number not for citation purposes) developed by the same authors [19].”
MethodSoubrier, S., Saulnier, F., Hubert, H., Delour, P., Lenci, H., Onimus, T., Nseir, S., & Durocher, A. (2007) · Intensive Care Medicine · doi:10.1007/s00134-007-0644-9 · Cited by 129
“The AUCs were then compared as previously described [ 26 ].”
ResultValk, G. D., de Sonnaville, J. J. J., van Houtum, W. H., Heine, R. J., van Eijk, J. T. M., Bouter, L. M., & Bertelsmann, F. W. (1997) · Muscle & Nerve · doi:10.1002/(sici)1097-4598(199701)20:1<116::aid-mus19>3.0.co;2-2 · Cited by 129
Trends in coronary artery bypass surgery results: a recent, 9-year study
Abramov, D., Tamariz, M. G., Fremes, S. E., Guru, V., Borger, M. A., Christakis, G. T., Bhatnagar, G., Sever, J. Y., & Goldman, B. S. (2000) · The Annals of Thoracic Surgery · doi:10.1016/s0003-4975(00)01249-2 · Cited by 129
Vignon, P., Hssain, A. A., François, B., Preux, P., Pichon, N., Clavel, M., Frat, J., & Gastinne, H. (2008) · Critical Care · doi:10.1186/cc6792 · Cited by 128
“AUC were then compared between Doppler parameters using a Hanley-McNeil test [ 29 ].”
MethodMausbach, B. T., Bowie, C. R., Harvey, P. D., Twamley, E. W., Goldman, S. R., Jeste, D. V., & Patterson, T. L. (2008) · Journal of Psychiatric Research · doi:10.1016/j.jpsychires.2006.12.008 · Cited by 125
Salaffi, F., Angelis, R. D., Carotti, M., Gutiérrez, M., Sarzi‐Puttini, P., & Atzeni, F. (2014) · Rheumatology International · doi:10.1007/s00296-014-2955-9 · Cited by 139
Schwarz, S. T., Xing, Y., Tomar, P., Bajaj, N. P. S., & Auer, D. P. (2016) · Radiology · doi:10.1148/radiol.2016160662 · Cited by 136
Baldeiras, I., Santana, I., Leitão, M. J., Gens, H., Pascoal, R., Tábuas-Pereira, M., Beato-Coelho, J., Duro, D., Almeida, M. R., & Oliveira, C. R. (2018) · Alzheimer's Research & Therapy · doi:10.1186/s13195-018-0362-2 · Cited by 118
“The ROC curves were compared according to the AUC comparison method of Hanley and McNeil [68] using MedCalc (version 11.6; MedCalc Software, Mariakerke, Belgium).”
MethodInfluentialComparing machine learning classifiers for diagnosing glaucoma from standard automated perimetry.
Goldbaum, M. H., Sample, P. A., Chan, K., Williams, J., Lee, T.-W., Blumenthal, E. Z., Girkin, C. A., Zangwill, L. M., Bowd, C., B, T. J. S. A., et al. (2002) · PubMed · Cited by 152
Comparison of test performance profile for blood tests of liver fibrosis in chronic hepatitis C
Halfon, P., Bacq, Y., Muret, A. D., Pénaranda, G., Bourlière, M., Ouzan, D., Tran, A., Botta, D., Renou, C., Bréchot, M. C., et al. (2006) · Journal of Hepatology · doi:10.1016/j.jhep.2006.09.020 · Cited by 133
“AUROCs were compared by the Hanley–McNeil method for paired data [12].”
MethodMethven, S., MacGregor, M. S., Traynor, J. P., O’Reilly, D. S. J., & Deighan, C. J. (2010) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfq140 · Cited by 128
“Receiver–operator characteristic (ROC) curves were constructed to allow comparison of assays for key threshold values of proteinuria, and comparison of the AUC was made using Hanley and McNeil's method [17] (MedCalc 10.”
MethodMammogram Segmentation by Contour Searching and Mass Lesions Classification With Neural Network
Cascio, D., Fauci, F., Magro, R., Raso, G., Bellotti, R., Carlo, F. D., Tangaro, S., Nunzio, G. D., Quarta, M., Forni, G., et al. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.878003 · Cited by 128
Huopio, J., Kr�ger, H., Honkanen, R., Jurvelin, J. S., Saarikoski, S., & ALHAVA, E. M. (2004) · Osteoporosis International · doi:10.1007/s00198-003-1534-9 · Cited by 146
“Statistical testing for ROC curves was performed using Roccomp software (Stata/SE 8.0, Stata Base Reference Manual, Volume 3, Stata Corp. College Station, Tex., USA) [ 11 ].”
MethodInfluentialIshii, J., Wang, J., Naruse, H., Taga, S., Kinoshita, M., Kurokawa, H., Iwase, M., Kondo, T., Nomura, M., Nagamura, Y., et al. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.8.1372 · Cited by 128
“A univariate Z-test was used to compare the areas under the ROC curves of indicators, as described by Hanley and McNeil [15].”
Method(1995) · Medical Decision Making · doi:10.1177/0272989x9501500204 · Cited by 127
Renner, J., Gruenewald, M., Quaden, R., Hanss, R., Meybohm, P., Steinfath, M., Scholz, J., & Bein, B. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181959864 · Cited by 127
Red cell distribution width as a novel predictor of mortality in ICU patients
Wang, F., Pan, W., Pan, S., Ge, J., Wang, S., & Chen, M. (2010) · Annals of Medicine · doi:10.3109/07853890.2010.521766 · Cited by 127
Enhanced dynamic landslide hazard mapping using MT-InSAR method in the Three Gorges Reservoir Area
Zhou, C., Cao, Y., Hu, X., Yin, K., Wang, Y., & Catani, F. (2022) · Landslides · doi:10.1007/s10346-021-01796-1 · Cited by 127
“The receiver operating characteristics (ROC) curve (Hanley and McNeil 1983) is used to assess the performance.”
MethodErzigkeit, H., Lehfeld, H., Peña‐Casanova, J., Bieber, F., Yekrangi-Hartmann, C., Rupp, M., Rappard, F., Arnold, K., & Hindmarch, I. (2001) · Dementia and Geriatric Cognitive Disorders · doi:10.1159/000051280 · Cited by 127
Bosch, A. M., Kessels, A. G. H., Beets, G. L., Jd, R., Koster, D., van Engelshoven, J. M. A., & MEYENFELDT, M. F. V. (2003) · European Journal of Radiology · doi:10.1016/s0720-048x(03)00081-0 · Cited by 127
“[24].”
Dynamic preload indicators fail to predict fluid responsiveness in open-chest conditions*
de Waal, E. E. C., Rex, S., Kruitwagen, C. L. J. J., Kalkman, C. J., & Bühre, W. (2009) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181958bf7 · Cited by 126
Uso de curvas ROC en investigación clínica: Aspectos teórico-prácticos
Jaime Cerda, L., & Cifuentes, L. I. (2012) · Revista chilena de infectología · doi:10.4067/s0716-10182012000200003 · Cited by 224
Teske, A. J., Cox, M. G. P. J., Boeck, B. W. L. D., Doevendans, P. A., Hauer, R. N. W., & Cramer, M. J. (2009) · Journal of the American Society of Echocardiography · doi:10.1016/j.echo.2009.05.014 · Cited by 126
Engberink, R. O., Kuiper, G. J. A. J. M., Wetzels, R. J. H., Nelemans, P. J., Lance, M. D., Beckers, E. A. M., & Henskens, Y. (2014) · Journal of Cardiothoracic and Vascular Anesthesia · doi:10.1053/j.jvca.2013.12.004 · Cited by 126
Pinker, K., Bickel, H., Helbich, T. H., Gruber, S., Dubsky, P. C., Pluschnig, U., Rudas, M., Bagó-Horváth, Z., Weber, M., Trattnig, S., et al. (2013) · European Radiology · doi:10.1007/s00330-013-2771-8 · Cited by 129
“Statistical differences between the AUCs were assessed using the method proposed byHanley andMcNeil [22].”
MethodĆwikła, J. B., Bodei, L., Kolasińska, A. D., Sankowski, A., Modlin, I. M., & Kidd, M. S. (2015) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2015-2792 · Cited by 127
“The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and the area under the curve (AUC) were calculated (MedCalc) (30) for AUC comparison and derivation of the Z-statistic (31) (MedCalc).”
MethodTsai, J.-C., Chen, C.-W., Chu, H., Yang, H.-L., Chung, M., Liao, Y., & Chou, K. (2016) · Archives of Psychiatric Nursing · doi:10.1016/j.apnu.2016.01.015 · Cited by 126
Potus, F., Pauciulo, M. W., Cook, E. K., Zhu, N., Hsieh, A., Welch, C. L., Shen, Y., Tian, L., Lima, P., Mewburn, J. D., et al. (2020) · Circulation · doi:10.1161/circulationaha.119.044320 · Cited by 133
“47), as analyzed according to the method described by Hanley and McNeil.(30) This observation confirms that TET2 expression has potential value as a biomarker for PAH.”
MethodInfluentialEng, J., Mysko, W. K., Weller, G. E. R., Renard, R., Gitlin, J. N., Bluemke, D. A., Magid, D., Kelen, G. D., & Scott, W. W. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.175.5.1751233 · Cited by 124
Motor control and strength as predictors of hamstring injury in elite players of Australian football
Cameron, M., Adams, R. D., & Maher, C. G. (2003) · Physical Therapy in Sport · doi:10.1016/s1466-853x(03)00053-1 · Cited by 148
“The area under the ROC curve is the most useful comparative measure of the performance of screening tests (Hanley and McNeil, 1982; Park et al., 2002), and a value over 0.”
BackgroundApfel, C. C., Greim, C. A., Haubitz, I., Grundt, D., Goepfert, C., Sefrin, P., & Roewer, N. (1998) · Acta Anaesthesiologica Scandinavica · doi:10.1111/j.1399-6576.1998.tb05158.x · Cited by 126
Boyle, J. G., Davidson, D. F., Perry, C. G., & Connell, J. M. C. (2007) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-2668 · Cited by 120
A comparison of the validity of GHQ-12 and CHQ-12 in Chinese primary care patients in Manchester
Pan, P.-C., & Goldberg, D. P. (1990) · Psychological Medicine · doi:10.1017/s003329170003662x · Cited by 125
Cummings, S. R., Marcus, R., Palermo, L., Ensrud, K. E., & Genant, H. K. (1994) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650090915 · Cited by 126
Lockwood, C. J., Wein, R., Lapinski, R. H., Casal, D., Berkowitz, G. S., Alvarez, M., & Berkowitz, R. L. (1993) · American Journal of Obstetrics and Gynecology · doi:10.1016/0002-9378(93)90008-7 · Cited by 126
Point-of-Care Ultrasound to Estimate Central Venous Pressure: A Comparison of Three Techniques*
Prekker, M. E., Scott, N. L., Hart, D. E., Sprenkle, M. D., & Leatherman, J. W. (2013) · Critical Care Medicine · doi:10.1097/ccm.0b013e31827466b7 · Cited by 135
Seo, E. H., Lee, D. Y., Lee, J. H., Choo, I. H., Kim, J. W., Kim, S. G., Park, S. Y., Shin, J. H., Do, Y. J., Yoon, J. C., et al. (2010) · American Journal of Geriatric Psychiatry · doi:10.1097/jgp.0b013e3181cab764 · Cited by 130
Development and Validation of a Prediction Rule Using the Oxford Classification in IgA Nephropathy
Tanaka, S., Ninomiya, T., Katafuchi, R., Masutani, K., Tsuchimoto, A., Noguchi, H., Hirakata, H., Tsuruya, K., & Kitazono, T. (2013) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.03480413 · Cited by 125
Gatti, M., Faletti, R., Calleris, G., Giglio, J., Berzovini, C., Gentile, F., Marra, G., Misischi, F., Molinaro, L., Bergamasco, L., et al. (2019) · Abdominal Radiology · doi:10.1007/s00261-019-01934-3 · Cited by 125
Forecasting US Recessions: The Role of Sentiments
Christiansen, C., Eriksen, J. N., & Møller, S. V. (2013) · Journal of Banking & Finance · doi:10.1016/j.jbankfin.2014.06.017 · Cited by 150
Yang, Z. K., & Gao, W. (2022) · Advanced Science · doi:10.1002/advs.202106043 · Cited by 140
A Multibiomarker-Based Outcome Risk Stratification Model for Adult Septic Shock*
Wong, H. R., Lindsell, C. J., Pettilä, V., Meyer, N. J., Thair, S. A., Karlsson, S., Russell, J. A., Fjell, C. D., Boyd, J. H., Ruokonen, E., et al. (2013) · Critical Care Medicine · doi:10.1097/ccm.0000000000000106 · Cited by 125
“Areas under the receiver operating characteristic (ROC) curves were compared using the method of Hanley and McNeil (15).”
MethodFombonne, E. (1991) · Journal of Child Psychology and Psychiatry · doi:10.1111/j.1469-7610.1991.tb00343.x · Cited by 125
Kaufer, D., Williams, C. S., Braaten, A., Gill, K., Zimmerman, S. I., & Sloane, P. D. (2008) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2008.05.006 · Cited by 137
Khandoker, A. H., Lai, D. T. H., Begg, R. K., & Palaniswami, M. S. (2007) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2007.906961 · Cited by 131
“In order to provide the relative importance of features, receiver-operating curve (ROC) analysis was used [28], [29], with the areas under the curves for each feature represented by the letter R.”
MethodInformation Fusion for Diabetic Retinopathy CAD in Digital Color Fundus Photographs
Niemeijer, M., Abràmoff, M. D., & van Ginneken, B. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.2012029 · Cited by 125
“However, the compound fusion method that also takes other lesion types into account clearly performs better and the difference between the AUC of both approaches is significant [22].”
BackgroundBagga, H., Greenfield, D. S., Feuer, W. J., & Knighton, R. W. (2003) · American Journal of Ophthalmology · doi:10.1016/s0002-9394(02)02077-9 · Cited by 125
Khwannimit, B., Bhurayanontachai, R., & Vattanavanit, V. (2017) · Journal of Critical Care · doi:10.1016/j.jcrc.2017.10.023 · Cited by 140
“Z statistic as described by Hanley and McNeil was used to compare the differences in the AUC of the scores in overall and subgroups of sepsis patients [25].”
MethodUse of Raman spectroscopy to screen diabetes mellitus with machine learning tools
Guevara, E., Torres‐Galván, J. C., Ramírez‐Elías, M. G., Luévano‐Contreras, C., & González, F. J. (2018) · Biomedical Optics Express · doi:10.1364/boe.9.004998 · Cited by 128
Alcohol Use and Pregnancy: Improving Identification
Chang, G. (1998) · Obstetrics & Gynecology · doi:10.1016/s0029-7844(98)00088-x · Cited by 124
“Because ROC curve comparisons were computed on the same subjects, the correction for correlation between samples was used to compare the areas.(16)”
MethodReimondo, G., Paccotti, P., Minetto, M., Termine, A., Stura, G., Bergui, M., Angeli, A., & Terzolo, M. (2003) · Clinical Endocrinology · doi:10.1046/j.1365-2265.2003.01776.x · Cited by 125
“However, the superiority of the CRH test has been demonstrated by the estimate of the area under the ROC curve, a measure of the overall accuracy of the test (Hanley & McNeil, 1982, 1983), which has been found significantly greater for the CRH test than the HDDST.”
MethodYoungstrom, E. A., Youngstrom, J. K., & Starr, M. (2005) · Biological Psychiatry · doi:10.1016/j.biopsych.2005.04.004 · Cited by 136
An ROC-type measure of diagnostic accuracy when the gold standard is continuous-scale
Obuchowski, N. A. (2005) · Statistics in Medicine · doi:10.1002/sim.2228 · Cited by 128
Kimmel, S. E., Berlin, J. A., Strom, B. L., & Laskey, W. K. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)00294-4 · Cited by 124
“The "final" model contained only those variables that added significant discriminatory ability to the model, as assessed by the area under the receiver operating characteristic curve (12-14).”
Methodvan Klei, W. A., Bryson, G. L., Yang, H., Kalkman, C. J., Wells, G. A., & Beattie, W. S. (2007) · Annals of Surgery · doi:10.1097/01.sla.0000261737.62514.63 · Cited by 123
Metadata
- Authors
- Hanley, J. A., & McNeil, B. J.
- Venue
- Radiology
- Published
- 1983-09
- Volume
- 148
- Issue
- 3
- Pages
- 839-843
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2102150307
- Cited by
- 7,016
- References
- 6
- Citations by year
- 2026: 93 · 2025: 143 · 2024: 153 · 2023: 187 · 2022: 238 · 2021: 243 · 2020: 229 · 2019: 261 · 2018: 249 · 2017: 220 · 2016: 273 · 2015: 282 · 2014: 290 · 2013: 287 · 2012: 306
- FWCI
- 8.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Radiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Physical Sciences › Computer Science › Artificial Intelligence › Imbalanced Data Classification Techniques
- Keywords
- receiver operating characteristic, area under the ROC curve, Wilcoxon statistic, diagnostic accuracy comparison, multiple readers, statistical power, standard error correction
- MeSH terms
- Models, Theoretical, Probability, Statistics as Topic, Technology, Radiologic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.