A method of comparing the areas under receiver operating characteristic curves derived from the same cases
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Receiver operating characteristic (ROC) curves are used to describe and compare the performance of diagnostic technology and diagnostic algorithms. This paper refines the statistical comparison of the areas under two ROC curves derived from the same set of patients by taking into account the correlation between the areas that is induced by the paired nature of the data. The correspondence between the area under an ROC curve and the Wilcoxon statistic is used and underlying Gaussian distributions (binormal) are assumed to provide a table that converts the observed correlations in paired ratings of images into a correlation between the two ROC areas. This between-area correlation can be used to reduce the standard error (uncertainty) about the observed difference in areas. This correction for pairing, analogous to that used in the paired t-test, can produce a considerable increase in the statistical sensitivity (power) of the comparison. For studies involving multiple readers, this method provides a measure of a component of the sampling variation that is otherwise difficult to obtain.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Changes in bacterial composition have been shown to serve as a primary driver of TMAO levels in other studies (10,15).”
From Prognostic Value of Elevated Levels of Intestinal Microbe-Generated Metabolite Trimethylamine-N-Oxide in Patients With Heart Failure (2014) · cites this paper as [15]
Citations
Cites
The meaning and use of the area under a receiver operating characteristic (ROC) curve.
Hanley, J. A., & McNeil, B. J. (1982) · Radiology · doi:10.1148/radiology.143.1.7063747 · Cited by 21,856 · cited 4×
“In a recent paper (4) we dealt with one popular accuracy index that can be derived from and used as a summary of the ROC curve.”
BackgroundMethodInfluentialSelf-citationBasic principles of ROC analysis
Metz, C. E. (1978) · Seminars in Nuclear Medicine · doi:10.1016/s0001-2998(78)80014-2 · Cited by 6,026
Dorfman, D. D., & Alf, E. (1969) · Journal of Mathematical Psychology · doi:10.1016/0022-2496(69)90019-4 · Cited by 874 · cited 1×
“tamed in three ways: (i) by the trapezoidal rule; (ii) as output from the Dorfman and Alf maximum likelihood estimation program (5); or (iu) from the slope and intercept of the original data when plotted on binormal graph paper (3).”
MethodROC Analysis Applied to the Evaluation of Medical Imaging Techniques
SWETS, J. A. (1979) · Investigative Radiology · doi:10.1097/00004424-197903000-00002 · Cited by 699 · cited 1×
“tamed in three ways: (i) by the trapezoidal rule; (ii) as output from the Dorfman and Alf maximum likelihood estimation program (5); or (iu) from the slope and intercept of the original data when plotted on binormal graph paper (3).”
MethodStatistical significance tests for binormal ROC curves
Metz, C. E., & Kronman, H. B. (1980) · Journal of Mathematical Psychology · doi:10.1016/0022-2496(80)90020-6 · Cited by 175 · cited 1×
“analogous to those used by Pollack and Hsieh (6) and Metz and Kronman (7).”
MethodSampling variability of the area under the ROC-curve and of d'e.
Pollack, I. W., & Hsieh, R. (1969) · Psychological Bulletin · doi:10.1037/h0026862 · Cited by 100
Cited by
Items 601–700 of 1,054
Ohuchida, K., Mizumoto, K., Ishikawa, N., Fujii, K., Konomi, H., Nagai, E., Yamaguchi, K., Tsuneyoshi, M., & Tanaka, M. (2005) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-05-0714 · Cited by 167
Airway Occlusion Pressure and Breathing Pattern as Predictors of Weaning Outcome
Sassoon, C. S. H., & Mahutte, C. K. (1993) · American Review of Respiratory Disease · doi:10.1164/ajrccm/148.4_pt_1.860 · Cited by 167
Intraepidermal nerve fiber density as a marker of early diabetic neuropathy
Umapathi, T., Tan, W. L., Loke, S. C., Soon, P. C., Tavintharan, S., & Chan, Y. H. (2007) · Muscle & Nerve · doi:10.1002/mus.20732 · Cited by 166
The Basilar Artery on Computed Tomography Angiography Prognostic Score for Basilar Artery Occlusion
Alemseged, F., Shah, D. G., Diomedi, M., Sallustio, F., Bivard, A., Sharma, G. J., Mitchell, P. J., Dowling, R., Bush, S. J., Yan, B., et al. (2017) · Stroke · doi:10.1161/strokeaha.116.015492 · Cited by 170
“Area under ROC curve (AROC) was compared using the method of Hanley and McNeill.(24) Multivariate binary logistic regression was performed with covariates included if P <0.”
InfluentialSweeney, R. W., Whitlock, R. H., Buckley, C. L., & Spencer, P. (1995) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/104063879500700411 · Cited by 166
The serotonin-N-acetylserotonin-melatonin pathway as a biomarker for autism spectrum disorders
Pagan, C., Delorme, R., Callebert, J., Goubran-Botros, H., Amsellem, F., Drouot, X., Boudebesse, C., Le Dudal, K., Ngo-Nguyen, N., Laouamri, H., et al. (2014) · Translational Psychiatry · doi:10.1038/tp.2014.120 · Cited by 165
Eugene W. Caldwell Lecture. Clinical efficacy of diagnostic imaging: love it or leave it.
Thornbury, J. R. (1994) · American Journal of Roentgenology · doi:10.2214/ajr.162.1.8273645 · Cited by 165
A systematic review of instruments to measure depressive symptoms in patients with schizophrenia
Lako, I. M., Bruggeman, R., Knegtering, H., Wiersma, D., Schoevers, R. A., Slooff, C. J., & Taxis, K. (2011) · Journal of Affective Disorders · doi:10.1016/j.jad.2011.10.014 · Cited by 183
“…sensitivity (not likely to miss cases of depression) combined with high specificity (not likely to misdiagnose depression) at the optimal cut-off value, i.e. the best balance between sensitivity and specificity determined by area under the receiver operating curve methods (Hanley and McNeil, 1983).”
BackgroundGalanaud, D., Perlbarg, V., Gupta, R., Stevens, R. D., Sanchez, P., Tollard, E., de Champfleur, N. M., Dinkel, J., Faivre, S., Soto-Ares, G., et al. (2012) · Anesthesiology · doi:10.1097/aln.0b013e3182755558 · Cited by 157
Predictive value of coronary calcifications for future cardiac events in asymptomatic individuals
Becker, A., Leber, A., Becker, C., & Knez, A. (2008) · American Heart Journal · doi:10.1016/j.ahj.2007.08.024 · Cited by 165
Multitarget Stool DNA Testing for Colorectal-Cancer Screening
(2014) · New England Journal of Medicine · doi:10.1056/nejmc1405215 · Cited by 164
Chiesa, C., Mira, M., Maccauro, M., Spreafico, C., Romito, R., Morosi, C., Camerini, T., Carrara, M., Pellizzari, S., Negri, A., et al. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3068-8 · Cited by 164
“Significance of the difference between AUC was tested for paired data, reducing the standard error (SE) as a consequence of Pearson’s correlation r of paired data (Table I in Hanley and McNeil [34]) SE2 ¼ SE12 þ SE22– 2 r SE1SE2 ð19Þ The statistical significance was obtained if z≥1.96, where z ¼ AUC1− AUC2j j= SE ð20Þ”
InfluentialShaw, L. J., Hausleiter, J., Achenbach, S. S., Al-Mallah, M. H., Berman, D. S., Budoff, M. J., Cademartiri, F., Callister, T. Q., Chang, H., Kim, Y.-J., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.05.062 · Cited by 164
“pretest CAD likelihood variable along with the CCTAdefined CAD, whereby areas were compared using an asymptotic p value calculation (15).”
MethodThe dynamic prediction of criminal recidivism: A three-wave prospective study.
Brown, S. L., Amand, M. D. S., & Zamble, E. (2008) · Law and Human Behavior · doi:10.1007/s10979-008-9139-7 · Cited by 182
“AUC values were compared using the test of correlated ROC areas outlined by Hanley and McNeil (1983) :”
MethodBazinet, M., Meshref, A. W., Trudel, C., Aronson, S., Péloquin, F., Nachabé, M., Bégin, L. R., & ELHILALI, M. M. (1994) · Urology · doi:10.1016/s0090-4295(94)80260-2 · Cited by 164
Diagnostic and prognostic value of circulating D-Dimers in patients with acute aortic dissection
Ohlmann, P., Faure, A., Morel, O., Petit, H., Kabbaj, H., Meyer, N., Cheneau, E. F., Jesel, L., Epailly, É., Desprez, D., et al. (2006) · Critical Care Medicine · doi:10.1097/01.ccm.0000216686.72457.ec · Cited by 169
Comparing Three-class Diagnostic Tests by Three-way ROC Analysis
Dreiseitl, S., Ohno-Machado, L., & Binder, M. (2000) · Medical Decision Making · doi:10.1177/0272989x0002000309 · Cited by 184
Rossi, E. (2002) · American Journal of Hypertension · doi:10.1016/s0895-7061(02)02969-2 · Cited by 164
Ivanov, J., Weisel, R. D., David, T. E., & Naylor, C. D. (1998) · Circulation · doi:10.1161/01.cir.97.7.673 · Cited by 164
“2 1841 (35) 189 (33) 2061 (42) 394 (40) 2403 (45) 800 (46)”
Ivanov, J., Tu, J. V., & Naylor, C. D. (1999) · Circulation · doi:10.1161/01.cir.99.16.2098 · Cited by 164
Selvachandran, S., Hodder, R., Ballal, M., Jones, P., & Cade, D. (2002) · The Lancet · doi:10.1016/s0140-6736(02)09549-1 · Cited by 163
Hemolysis: A harbinger of adverse outcome after left ventricular assist device implant
Cowger, J. A., Romano, M. A., Shah, P. M., Shah, N., Mehta, V., Haft, J. W., Aaronson, K. D., & Pagani, F. D. (2013) · The Journal of Heart and Lung Transplantation · doi:10.1016/j.healun.2013.08.021 · Cited by 167
Aplicações da curva ROC em estudos clínicos e experimentais
Polo, T. C. F., & Miot, H. A. (2020) · Jornal Vascular Brasileiro · doi:10.1590/1677-5449.200186 · Cited by 163
Wang, S., Xiang, J., Li, Z., Lu, S., Hu, J., Gao, X., Yu, L., Wang, L., Wang, J., Wu, Y., et al. (2015) · International Journal of Cancer · doi:10.1002/ijc.28136 · Cited by 162
Fuh, J. L., Teng, E. L., Lin, K. N., Larson, E. B., Wang, S. J., Liu, C. Y., Chou, P., Kuo, B. I. T., & Liu, H. C. (1995) · Neurology · doi:10.1212/wnl.45.1.92 · Cited by 162
Vellutino, F. R., Scanlon, D. M., Zhang, H., & Schatschneider, C. W. (2007) · Reading and Writing · doi:10.1007/s11145-007-9098-2 · Cited by 183
Detecting Suicide Risk in a Pediatric Emergency Department: Development of a Brief Screening Tool
Horowitz, L. M., Wang, P. S., Koocher, G. P., Burr, B. H., Smith, M. F., Klavon, S., & Cleary, P. D. (2001) · Pediatrics · doi:10.1542/peds.107.5.1133 · Cited by 148
Rosenberg, S. D., Drake, R. E., Wolford, G. L., Mueser, K. T., Oxman, T. E., Vidaver, R. M., Carrieri, K. L., & Luckoor, R. (1998) · American Journal of Psychiatry · doi:10.1176/ajp.155.2.232 · Cited by 162
Addiction versus stages of change models in predicting smoking cessation
Farkas, A. J., Pierce, J. P., Zhu, S., Rosbrook, B. P., Gilpin, E. A., Berry, C. C., & Kaplan, R. M. (1996) · Addiction · doi:10.1111/j.1360-0443.1996.tb03608.x · Cited by 200
“Finally, we tested the mean curve areas for the two equations to determine if they differed statistically (Hanley & McNeil, 1983).”
MethodAraya, R., Wynn, R., & Lewis, G. (1992) · Social Psychiatry and Psychiatric Epidemiology · doi:10.1007/bf00789001 · Cited by 162
Non-invasive diagnosis of endometriosis based on a combined analysis of six plasma biomarkers
Mihalyi, A., Gevaert, O., Kyama, C. M., Simsa, P., Pochet, N., De Smet, F., De Moor, B., Meuleman, C., Billen, J., Blanckaert, N., et al. (2010) · Human Reproduction · doi:10.1093/humrep/dep425 · Cited by 161
The Novel Biomarker Growth Differentiation Factor 15 in Heart Failure with Normal Ejection Fraction
Stahrenberg, R., Edelmann, F., Mende, M., Kockskämper, A., Düngen, H.-D., Lüers, C., Binder, L., Herrmann-Lingen, C., Gelbrich, G., Hasenfuß, G., et al. (2010) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfq151 · Cited by 161
“The areas under the curve (AUC) were compared by the method of Hanley and McNeil.(22) P-values ,0.”
MethodInfluentialYip, S. S. F., Kim, J., Coroller, T. P., Parmar, C., Velazquez, E. R., Huynh, E., Mak, R. H., & Aerts, H. J. W. L. (2017) · Journal of Nuclear Medicine · doi:10.2967/jnumed.116.181826 · Cited by 161
“To assess whether the radiomic features significantly outperformed the conventional features in predicting mutation status, the receiveroperating-characteristic (ROC) curves of the radiomic features with the highest AUCs were compared with the ROC curves of MTV and SUVmax using a bootstrap test (38).”
MethodSolitary Pulmonary Nodules: Clinical Prediction Model Versus Physicians
Swensen, S. J., Silverstein, M. D., Edell, E. S., Trastek, V. F., Aughenbaugh, G. L., Ilstrup, D. M., & Schleck, C. D. (1999) · Mayo Clinic Proceedings · doi:10.4065/74.4.319 · Cited by 161
Prosen, G., Klemen, P., Strnad, M., & Grmec, Š. (2011) · Critical Care · doi:10.1186/cc10140 · Cited by 161
“Hanley JA, McNeil BJ: A method of comparing the areas under receiver operating characteristic curves derived from the same cases.”
MethodLu, S., Wang, J., Liu, S., Hung, C., Chen, C., Tung, H., Chen, T., Huang, W., Lee, C., Chen, C., et al. (2006) · Cancer · doi:10.1002/cncr.22242 · Cited by 161
“The differences between 2 ROC curves are expressed as the difference between the areas under the ROC curves (AUC).(23,24) The ‘‘distance’’ between the sensitivity and specificity of each point and the ideal point (sensitivity 1⁄4 1 and specificity 1⁄4 1) was calculated.”
BackgroundBaesens, B., Verstraeten, G., Van den Poel, D., Egmont-Petersen, M., Van Kenhove, P., & Vanthienen, J. (2004) · European Journal of Operational Research · doi:10.1016/s0377-2217(03)00043-2 · Cited by 161
A prediction model for type 2 diabetes risk among Chinese people
Chien, K., Cai, T., Hsu, H., Su, T., Chang, W., Chen, M., Lee, Y.-C., & Hu, F. B. (2008) · Diabetologia · doi:10.1007/s00125-008-1232-4 · Cited by 170
“An AUC curve is a graph of sensitivity vs 1–specificity (or false-positive rate) for various cut-off definitions of a positive diagnostic test result [ 31 ].”
BackgroundInternal and external validity of the WHO Well‐Being Scale in the elderly general population
Heun, R., Burkart, M., Maier, W., & Bech, P. (1999) · Acta Psychiatrica Scandinavica · doi:10.1111/j.1600-0447.1999.tb00973.x · Cited by 160
Predictive radiogenomics modeling of EGFR mutation status in lung cancer
Gevaert, O., Echegaray, S., Khuong, A., Hoang, C. D., Shrager, J. B., Jensen, K. C., Berry, G. J., Guo, H. H., Lau, C., Plevritis, S. K., et al. (2017) · Scientific Reports · doi:10.1038/srep41674 · Cited by 160
Carmona-Bayonas, A., Jiménez-Fonseca, P., Virizuela Echaburu, J., Antonio, M., Font, C., Biosca, M., Ramchandani, A., Martínez, J., Hernando Cubero, J., Espinosa, J., et al. (2015) · Journal of Clinical Oncology · doi:10.1200/jco.2014.57.2347 · Cited by 160
The relationship between mandibular bone mineral density and panoramic radiographic measurements
Horner, K., & Devlin, H. (1998) · Journal of Dentistry · doi:10.1016/s0300-5712(97)00020-1 · Cited by 160
An Expanded Risk Prediction Model for Lung Cancer
Spitz, M. R., Etzel, C. J., Dong, Q., Amos, C. I., Wei, Q., Wu, X., & Hong, W. K. (2008) · Cancer Prevention Research · doi:10.1158/1940-6207.capr-08-0060 · Cited by 160
“We performed pairwise comparisons (8) of the area under the receiver operator characteristic curve (AUC) for (a) the baseline multiple logistic model, (b) the multiple logistic model with the DNA repair capacity variable added, (c) the multiple logistic model with bleomycin sensitivity added, and (d) the multiple logi…”
MethodOutcome prediction in intensive care: results of a prospective, multicentre, Portuguese study
Moreno, R., & Morais, P. (1997) · Intensive Care Medicine · doi:10.1007/s001340050313 · Cited by 160
“The comparison of the areas under ROC curves was done using the Z statistic with correction for the correlation introduced by studying the same sample [ 35 ].”
MethodLee, S. K., Zupancic, J. A. F., Pendray, M. R., Thiessen, P. N., Schmidt, B. K., Whyte, R. K., Shorten, D., & Stewart, S. D. (2001) · The Journal of Pediatrics · doi:10.1067/mpd.2001.115576 · Cited by 160
Multiple SNP testing improves risk prediction of first venous thrombosis
de Haan, H. G., Bezemer, I. D., Doggen, C. J. M., Le Cessie, S., Reitsma, P. H., Arellano, A. R., Tong, C. H., Devlin, J. J., Bare, L. A., Rosendaal, F. R., et al. (2012) · Blood · doi:10.1182/blood-2011-12-397752 · Cited by 160
Pettilä, V., Pettilä, M., Sarna, S., Voutilainen, P., & Takkunen, O. (2002) · Critical Care Medicine · doi:10.1097/00003246-200208000-00005 · Cited by 160
Sigal, R., Vogl, T., Casselman, J., Moulin, G., Veillon, F., Hermans, R., Dubrulle, F., Viala, J., Bosq, J., Mack, M., et al. (2002) · European Radiology · doi:10.1007/s003300101130 · Cited by 160
“That pairing of pre- and postcontrast MR examinations was taken into account in the statistical comparison of the AUCs.”
MethodRominger, A., Saam, T., Vogl, E., Übleis, C., la Fougère, C., Förster, S., Haug, A., Cumming, P., Reiser, M. F., Nikolaou, K., et al. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.070672 · Cited by 159
“To identify the optimal TBR threshold value, receiveroperating-characteristic analysis was performed (15).”
MethodMonnet, X., Bataille, A., Magalhaes, E., Barrois, J., Le Corre, M., Gosset, C., Guerin, L., Richard, C., & Teboul, J.-L. (2013) · Intensive Care Medicine · doi:10.1007/s00134-012-2693-y · Cited by 159
Tao, Y., Sam, L., Li, J., Friedman, C., & Lussier, Y. A. (2007) · Bioinformatics · doi:10.1093/bioinformatics/btm195 · Cited by 159
“Because in biological predictions a low FPR is usually more desirable than a high TPR, we used the ROC area comparison method (Hanley and McNeil, 1983) in only the areas of those ROC curves where the FPR was below 0.”
InfluentialCombination of bone mineral density and upper femur geometry improves the prediction of hip fracture
Pulkkinen, P., Partanen, J., Jalovaara, P., & J�ms�, T. (2004) · Osteoporosis International · doi:10.1007/s00198-003-1556-3 · Cited by 159
“Statistical comparison between the areas under the ROC curves was also performed [24].”
MethodBiomarkers for the prediction of liver fibrosis in patients with chronic alcoholic liver disease
Naveau, S., Raynard, B., Ratziu, V., Abella, A., Imbert–bismut, F., Messous, D., Beuzen, F., Capron, F., Thabut, D., Munteanu, M., et al. (2005) · Clinical Gastroenterology and Hepatology · doi:10.1016/s1542-3565(04)00625-1 · Cited by 159
Pearce, J. L., Cherry, K., M., D., S., F., & Whish, G. (2001) · Journal of Applied Ecology · doi:10.1046/j.1365-2664.2001.00608.x · Cited by 155
Timmerman, D., Bourne, T. H., Tailor, A., Collins, W. P., Verrelst, H., Vandenberghe, K., & Vergote, I. (1999) · American Journal of Obstetrics and Gynecology · doi:10.1016/s0002-9378(99)70436-9 · Cited by 159
Ladenheim, M. L., Kotler, T. S., Pollock, B. H., Berman, D. S., & Diamond, G. A. (1987) · The American Journal of Cardiology · doi:10.1016/0002-9149(87)90798-3 · Cited by 159
Diet, cardiovascular disease, and mortality in 80 countries
Mente, A., Dehghan, M., Rangarajan, S., O’Donnell, M., Hu, W., Dagenais, G., Wielgosz, A., A. Lear, S., Wei, L., Diaz, R., et al. (2023) · European Heart Journal · doi:10.1093/eurheartj/ehad269 · Cited by 158
“the PURE score.(42) The predictive performance of each Cox model was measured by the area under the receiver-operating characteristic curve (AUC).”
MethodFortes, M. B., Owen, J. A., Raymond-Barker, P., Bishop, C., Elghenzai, S., Oliver, S. J., & Walsh, N. P. (2015) · Journal of the American Medical Directors Association · doi:10.1016/j.jamda.2014.09.012 · Cited by 158
Pothuaud, L., Lespessailles, E., Harba, R., Jennane, R., Royant, V., Eynard, E., & Benhamou, C. L. (1998) · Osteoporosis International · doi:10.1007/s001980050108 · Cited by 158
“[23,24].”
Local Diabetic Retinopathy Prediction by Multifocal ERG Delays over 3 Years
Ng, J. S., Bearse, M. A., Schneck, M. E., Barez, S., & Adams, A. J. (2008) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.07-1157 · Cited by 158
Artificial Neural Networks Applied to Survival Prediction in Breast Cancer
Lundin, J. E., Lundin, J. E., BURKE, H. B., Toikkanen, S., Pylkkänen, L. H., & Joensuu, H. (1999) · Oncology · doi:10.1159/000012061 · Cited by 175
“The statistical comparison of the areas under two ROC curves was performed according to Hanley and McNeil [22].”
MethodDubos, F., Korczowski, B., Aygun, D. A., Martinot, A., Prat, C., Galetto-Lacour, A., Casado-Flores, J., Taskin, E., Leclerc, F., Rodrigo, C., et al. (2008) · Archives of Pediatrics & Adolescent Medicine · doi:10.1001/archpedi.162.12.1157 · Cited by 153
Upper and Lower Tear Menisci in the Diagnosis of Dry Eye
Shen, M., Li, J., Wang, J., Ma, H., Cai, C. C., Tao, A., Yuan, Y., & Lü, F. (2009) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.08-2704 · Cited by 158
“Diagnostic variables for ATD were analyzed by receiver operating characteristics (ROC) curves, and the areas under the ROC curves (AUC) were compared.(22) To construct the ROC curves, the sensitivity, measured as the proportion of ATD patients who were positive for the variable, and the specificity, measured as the pr…”
MethodCross-Validation of a Screener to Predict Opioid Misuse in Chronic Pain Patients (SOAPP-R)
Butler, S. F., Budman, S. H., Fernandez, K. C., Fanciullo, G. J., & Jamison, R. N. (2009) · Journal of Addiction Medicine · doi:10.1097/adm.0b013e31818e41da · Cited by 156
Utility of the Surgical Apgar Score: Validation in 4119 Patients
Regenbogen, S. E., Ehrenfeld, J. M., Lipsitz, S. R., Greenberg, C. C., Hutter, M. M., & Gawande, A. A. (2009) · Archives of Surgery · doi:10.1001/archsurg.2008.504 · Cited by 193
Lipid accumulation product: a powerful marker of metabolic syndrome in healthy population
Taverna, M. J., Martínez-Larrad, M. T., Frechtel, G. D., & Serrano‐Ríos, M. (2011) · European Journal of Endocrinology · doi:10.1530/eje-10-1039 · Cited by 178
“75 [11].”
Weinstein, M. C., Berwick, D. M., Goldman, P. A., Murphy, J. M., & Barsky, A. J. (1989) · Medical Care · doi:10.1097/00005650-198906000-00003 · Cited by 157
Haase‐Fielitz, A., Bellomo, R., Devarajan, P., Bennett, M., Story, D., Matalanis, G. S., Frei, U. A., Dragun, D., & Haase, M. (2009) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfp234 · Cited by 179
Quaia, E., D’Onofrio, M., Palumbo, A., Rossi, S., Bruni, S., & Cova, M. A. (2006) · European Radiology · doi:10.1007/s00330-006-0192-7 · Cited by 157
“Areas under the curves (Az) were compared by the Hanley-McNeil method for paired data [25].”
MethodLarge‐scale environmental correlates of forest tree distributions in Catalonia (NE Spain)
Thuiller, W., Vayreda, J., Pino, J., Sabaté, S., Lavorel, S., & Gràcia, C. (2003) · Global Ecology and Biogeography · doi:10.1046/j.1466-822x.2003.00033.x · Cited by 170
“We used the Receiver Operating Characteristic curve (ROC curve) to evaluate the accuracy of our models (Hanley & McNeil, 1982, 1983).”
MethodFletcher, J. W., Kymes, S. M., Gould, M. K., Alazraki, N. P., Coleman, R. E., Lowe, V. J., Marn, C. S., Segall, G. M., Thet, L. A., Lee, K., et al. (2008) · Journal of Nuclear Medicine · doi:10.2967/jnumed.107.044990 · Cited by 157
“AUCs for the 2 modalities were compared accounting for correlation between test results because each participant acted as his own control (20).”
MethodHeslop, C., Frohlich, J. J., & Hill, J. S. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.11.050 · Cited by 156
Arena, R. A., MYERS, J. N., Aslam, S. S., Varughese, E. B., & Peberdy, M. A. (2003) · CHEST Journal · doi:10.1378/chest.124.2.720 · Cited by 164
Nasogastric aspirate predicts high-risk endoscopic lesions in patients with acute upper-GI bleeding
Aljebreen, A., Fallone, C. A., Barkun, A. N., & for the RUGBE investigators (2004) · Gastrointestinal Endoscopy · doi:10.1016/s0016-5107(03)02543-4 · Cited by 156
Grenne, B. L., Eek, C. H., Sjøli, B., Dahlslett, T., Uchto, M., Hol, P. K., Skulstad, H., Smiseth, O. A., Edvardsen, T., & Brunvand, H. (2010) · Heart · doi:10.1136/hrt.2009.188391 · Cited by 156
“The data were analysed using standard statistical software (SPSS version16.0). Continuous variables are presented as mean±SD or median (interquartile range). Differences between groups were analysed using Student t test, Mann–Whitney U test or one-way analysis of variance with Bonferroni correction applied for post ho…”
MethodMasson, S., Latini, R., Carbonieri, E., Moretti, L., Rossi, M. G., Ciricugno, S., Milani, V., Marchioli, R., Struck, J., Bergmann, A., et al. (2010) · European Journal of Heart Failure · doi:10.1093/eurjhf/hfp206 · Cited by 167
“The prognostic discrimination of each biomarker was established from the area under the receiver operating characteristic (ROC) curve (AUC) which is equivalent to the c-index, and compared with that of BNP or NT-proBNP with the test of Hanley and McNeil.(13) The increased discriminative value of the biomarkers for bot…”
Methodvon Haehling, S., Jankowska, E. A., Morgenthaler, N. G., Vassanelli, C., Zanolla, L., Rozentryt, P., Filippatos, G. S., Doehner, W., Koehler, F., Papassotiriou, J., et al. (2007) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.08.012 · Cited by 155
de Vries, M., Ouwendijk, R., Kessels, A. G. H., de Haan, M. W., Flobbe, K., Hunink, M. G. M., van Engelshoven, J. M. A., & Nelemans, P. J. (2005) · Journal of Vascular Surgery · doi:10.1016/j.jvs.2004.11.022 · Cited by 174
Giacchetti, G., Ronconi, V., Lucarelli, G., Boscaro, M., & Mantero, F. (2006) · Journal of Hypertension · doi:10.1097/01.hjh.0000217857.20241.0f · Cited by 154
Macrophage Inhibitory Cytokine 1: A New Prognostic Marker in Prostate Cancer
Brown, D. A., Lindmark, F., Stattin, P., Bälter, K., Adami, H.-O., Zheng, S. L., Xu, J., Isaacs, W. B., Grönberg, H., Breit, S. N., et al. (2009) · Clinical Cancer Research · doi:10.1158/1078-0432.ccr-08-3126 · Cited by 152
“scribed by Hanley and coworkers (16), which accounts for the fact that”
BackgroundDealing with Missing Predictor Values When Applying Clinical Prediction Models
Janssen, K. J. M., Vergouwe, Y., Donders, A. R. T., Harrell, F. E., Chen, Q., Grobbee, D. E., & Moons, K. G. M. (2009) · Clinical Chemistry · doi:10.1373/clinchem.2008.115345 · Cited by 151
Chen, J. M., Levin, H. R., Michler, R. E., Prusmack, C. J., Rose, E. A., & Aaronson, K. D. (1997) · Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/s0022-5223(97)70053-9 · Cited by 154
Youngstrom, E. A., Findling, R. L., Calabrese, J. R., Gracious, B., Demeter, C., Bedoya, D., & PRICE, M. (2004) · Journal of the American Academy of Child & Adolescent Psychiatry · doi:10.1097/01.chi.0000125091.35109.1e · Cited by 167
“We evaluated the reproducibility of results by using bootstrapping (500 resamples for each of the 10 imputed samples for both age groups, totaling 10,000 resamples) (Efron, 1982) and by comparing the generalizability of test performance across the two age groups by using the z test for independent AUCs (Hanley and McN…”
MethodInfluentialLe Fevre, P., Devereux, J., Smith, S., Lawrie, S. M., & Cornbleet, M. (1999) · Palliative Medicine · doi:10.1191/026921699671260095 · Cited by 152
Yılmaz, M. İ., Siriopol, D. C., Sağlam, M., Kurt, Y. G., Ünal, H. U., Eyileten, T., Gök, M., Çetinkaya, H., Oğuz, Y., Sarı, S., et al. (2014) · Kidney International · doi:10.1038/ki.2014.227 · Cited by 155
Kobayashi, H., Nemoto, T., Koshikawa, H., Osono, Y., Yamazawa, R., MURAKAMI, M., Kashima, H., & Mizuno, M. (2008) · Schizophrenia Research · doi:10.1016/j.schres.2008.08.018 · Cited by 159
“The difference of the AUC among methods was calculated with a z test (Hanley and McNeil, 1983).”
Kim, N. R., Lee, E. S., Seong, G. J., Kang, S. Y., Kim, J. H., Hong, S. H., & Kim, C. Y. (2010) · British Journal of Ophthalmology · doi:10.1136/bjo.2010.182493 · Cited by 153
“test or Fisher exact test. To compare the diagnostic ability of RNFL and GCC in both highly myopic and non-highly myopic groups, area under the receiver operator characteristic curves were generated to assess the ability of each parameter to detect glaucomatous changes. Differences in AUROC between RNFL and GCC were t…”
MethodDeykin, A., Massaro, A. F., Drazen, J. M., & Israel, E. (2002) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.2201081 · Cited by 152
Clinical usefulness of microarray‐based IgE detection in children with suspected food allergy
Ott, H., Baron, J. M., Heise, R., Ocklenburg, C., Stanzel, S., Merk, H. ‐., Niggemann, B., & Beyer, K. (2008) · Allergy · doi:10.1111/j.1398-9995.2008.01748.x · Cited by 149
“For comparison of the AUC obtained by microarray analysis and FEIA testing, nonparametric paired Wilcoxon tests were conducted for each component as proposed by Hanley and McNeil (15).”
MethodThiel, S. W., Kollef, M. H., & Isakow, W. (2009) · Critical Care · doi:10.1186/cc7955 · Cited by 150
“The areas under receiver operating characteristic (ROC) curves are expressed as the area ± standard error, and were compared using the Hanley-McNeil method [22].”
MethodJohnson, G., Burvill, P. W., Anderson, C. S., Jamrozik, K., Stewart‐Wynne, E. G., & Chakera, T. M. H. (1995) · Acta Psychiatrica Scandinavica · doi:10.1111/j.1600-0447.1995.tb09778.x · Cited by 151
Kim, K. W., Lee, D. Y., Jhoo, J. H., Youn, J. C., Suh, Y. J., Jun, Y. H., Seo, E. H., & Woo, J. I. (2005) · Dementia and Geriatric Cognitive Disorders · doi:10.1159/000084558 · Cited by 148
Ruano, R., Lazar, D. A., Cass, D. L., Zamora, I. J., Lee, T. C., Cassady, C. I., Mehollin-Ray, A. R., Welty, S. E., Fernandes, C. J., Haeri, S., et al. (2013) · Ultrasound in Obstetrics and Gynecology · doi:10.1002/uog.13223 · Cited by 153
A score to predict early risk of recurrence after ischemic stroke
Ay, H., Güngör, L., Arsava, E. M., Rosand, J. M., Vangel, M. G., Benner, T., Schwamm, L. H., Furie, K. L., Koroshetz, W. J., & Sorensen, A. G. (2009) · Neurology · doi:10.1212/wnl.0b013e3181ca9cff · Cited by 158
“ACE inhibitor/angiotensin receptor blocker 375 (27) 16 (27) 0.”
Salaffi, F., Carotti, M., Iagnocco, A., Luccioli, F., Ramonda, R., Sabatini, E., Nicola, M. D., Maggi, M., Priori, R., Valesini, G., et al. (2008) · Rheumatology · doi:10.1093/rheumatology/ken222 · Cited by 151
“The non-parametric Wilcoxon’s signedrank test was used for calculation and comparison of the areas under the ROC curves (AUC-ROCs) derived from the sample of patients, as suggested by Hanley and McNeil [ 20 ].”
MethodBodei, L., Kidd, M. S., Modlin, I. M., Severi, S., Drozdov, I. A., Nicolini, S., Kwekkeboom, D. J., Krenning, E. P., Baum, R. P., & Paganelli, G. (2015) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-015-3250-z · Cited by 153
“AUCs were compared and the Z-statistic derived [24] (MedCalc).”
MethodMueller, T., Gegenhuber, A., Poelz, W., & Haltmayer, M. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2003.10.027 · Cited by 151
“Comparisons between the areas under curve were assessed according to the method by Hanley and McNeil [18].”
MethodChen, W., Xu, X.-K., Li, J.-L., Kong, K.-K., Li, H., Chen, C., He, J., Wang, F., Li, P., Ge, X.-S., et al. (2017) · Oncotarget · doi:10.18632/oncotarget.15199 · Cited by 150
“Area under the ROC curve (AUC) was used as an accuracy index for evaluating the predictive performance of suspected lncRNA [40].”
MethodMartini, C. H., Boon, M., Broens, S. J. L., Hekkelman, E. F., Oudhoff, L. A., Buddeke, A. W., & Dahan, A. (2015) · Anesthesiology · doi:10.1097/aln.0000000000000757 · Cited by 159
Olsson, T., & Lind, L. (2003) · Academic Emergency Medicine · doi:10.1111/j.1553-2712.2003.tb00572.x · Cited by 172
Metadata
- Authors
- Hanley, J. A., & McNeil, B. J.
- Venue
- Radiology
- Published
- 1983-09
- Volume
- 148
- Issue
- 3
- Pages
- 839-843
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2102150307
- Cited by
- 7,016
- References
- 6
- Citations by year
- 2026: 93 · 2025: 143 · 2024: 153 · 2023: 187 · 2022: 238 · 2021: 243 · 2020: 229 · 2019: 261 · 2018: 249 · 2017: 220 · 2016: 273 · 2015: 282 · 2014: 290 · 2013: 287 · 2012: 306
- FWCI
- 8.95
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Radiology (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
- Physical Sciences › Mathematics › Statistics and Probability › Statistical Methods in Epidemiology
- Physical Sciences › Computer Science › Artificial Intelligence › Imbalanced Data Classification Techniques
- Keywords
- receiver operating characteristic, area under the ROC curve, Wilcoxon statistic, diagnostic accuracy comparison, multiple readers, statistical power, standard error correction
- MeSH terms
- Models, Theoretical, Probability, Statistics as Topic, Technology, Radiologic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.