Reduction of CT artifacts caused by metallic implants.
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A technique to reduce metallic implant artifacts on computed tomography scans is presented. The implant boundaries are determined semiautomatically; the missing projection data are replaced by linear interpolation. The complete procedure requires 1-2 minutes per scan. Images with greatly improved quality were obtained in the presence of surgical clips and pelvic implants; success is limited in highly structured regions, such as the facial skull.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image Reconstruction from Projections
(2004) · Biomedical Engineering · doi:10.1201/9780203492543.ch9 · Cited by 915
Row-Action Methods for Huge and Sparse Systems and Their Applications
Censor, Y. (1981) · SIAM Review · doi:10.1137/1023097 · Cited by 484
Cited by
Schulze, R., Heil, U., Groβ, D., Bruellmann, D., Dranischnikow, E., Schwanecke, U., & Schoemer, E. (2011) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/30642039 · Cited by 999
CT artifacts: causes and reduction techniques
Boas, F. E., & Fleischmann, D. (2012) · Imaging in Medicine · doi:10.2217/iim.12.13 · Cited by 848
Convolutional Neural Network Based Metal Artifact Reduction in X-Ray Computed Tomography
Zhang, Y., & Yu, H. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2823083 · Cited by 493
Iterative deblurring for CT metal artifact reduction
Wang, G., Snyder, D. L., O'Sullivan, J. A., & Vannier, M. W. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538943 · Cited by 409
Current and Novel Techniques for Metal Artifact Reduction at CT: Practical Guide for Radiologists
Katsura, M., Sato, J., Akahane, M., Kunimatsu, A., & Abe, O. (2018) · RadioGraphics · doi:10.1148/rg.2018170102 · Cited by 343
Metadata
- Authors
- Kalender, W. A., Hebel, R., & Ebersberger, J.
- Venue
- Radiology
- Published
- 1987-08
- Volume
- 164
- Issue
- 2
- Pages
- 576-577
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2154129661
- Cited by
- 751
- References
- 2
- FWCI
- 0.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.