Reduction of CT artifacts caused by metallic implants.
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A technique to reduce metallic implant artifacts on computed tomography scans is presented. The implant boundaries are determined semiautomatically; the missing projection data are replaced by linear interpolation. The complete procedure requires 1-2 minutes per scan. Images with greatly improved quality were obtained in the presence of surgical clips and pelvic implants; success is limited in highly structured regions, such as the facial skull.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image Reconstruction from Projections
(2004) · Biomedical Engineering · doi:10.1201/9780203492543.ch9 · Cited by 915
Row-Action Methods for Huge and Sparse Systems and Their Applications
Censor, Y. (1981) · SIAM Review · doi:10.1137/1023097 · Cited by 484
Cited by
Schulze, R., Heil, U., Groβ, D., Bruellmann, D., Dranischnikow, E., Schwanecke, U., & Schoemer, E. (2011) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/30642039 · Cited by 999
CT artifacts: causes and reduction techniques
Boas, F. E., & Fleischmann, D. (2012) · Imaging in Medicine · doi:10.2217/iim.12.13 · Cited by 848
Convolutional Neural Network Based Metal Artifact Reduction in X-Ray Computed Tomography
Zhang, Y., & Yu, H. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2823083 · Cited by 493
Iterative deblurring for CT metal artifact reduction
Wang, G., Snyder, D. L., O'Sullivan, J. A., & Vannier, M. W. (1996) · IEEE Transactions on Medical Imaging · doi:10.1109/42.538943 · Cited by 409
Current and Novel Techniques for Metal Artifact Reduction at CT: Practical Guide for Radiologists
Katsura, M., Sato, J., Akahane, M., Kunimatsu, A., & Abe, O. (2018) · RadioGraphics · doi:10.1148/rg.2018170102 · Cited by 343
Metal streak artifacts in X-ray computed tomography: a simulation study
De Man, B., Nuyts, J., Dupont, P., Marchal, G., & Suetens, P. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.775600 · Cited by 311
Improved total variation-based CT image reconstruction applied to clinical data
Ritschl, L., Bergner, F., Fleischmann, C., & Kachelrieß, M. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/6/003 · Cited by 306
Evaluation of Two Iterative Techniques for Reducing Metal Artifacts in Computed Tomography
Boas, F. E., & Fleischmann, D. (2011) · Radiology · doi:10.1148/radiol.11101782 · Cited by 303
Metal Artifact Reduction in CT: Where Are We After Four Decades?
Gjesteby, L., De Man, B., Jin, Y., Paganetti, H., Verburg, J., Giantsoudi, D., & Wang, G. (2016) · IEEE Access · doi:10.1109/access.2016.2608621 · Cited by 290
Multiscale X-ray tomography of cementitious materials: A review
Brisard, S., Serdar, M., & Monteiro, P. J. M. (2020) · Cement and Concrete Research · doi:10.1016/j.cemconres.2019.105824 · Cited by 260
DuDoNet: Dual Domain Network for CT Metal Artifact Reduction
Lin, W.-A., Liao, H., Peng, C., Sun, X., Zhang, J., Luo, J., Chellappa, R., & Zhou, S. K. (2019) · 2019 IEEE/CVF Conference on Computer Vision and Pattern Recognition (CVPR) · doi:10.1109/cvpr.2019.01076 · Cited by 254
X-ray CT metal artifact reduction using wavelets: an application for imaging total hip prostheses
Zhao, S., Robeltson, D. D., Wang, G., Whiting, B., & Bae, K. T. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.897816 · Cited by 244
Dual-Energy CT for the Musculoskeletal System
Mallinson, P. I., Coupal, T. M., McLaughlin, P. D., Nicolaou, S., Munk, P. L., & Ouellette, H. A. (2016) · Radiology · doi:10.1148/radiol.2016151109 · Cited by 242
Metal artifact reduction in CT using tissue-class modeling and adaptive prefiltering
Bal, M., & Spies, L. (2006) · Medical Physics · doi:10.1118/1.2218062 · Cited by 234
Mahnken, A. H., Raupach, R., Wildberger, J. E., Jung, B., Heussen, N., Flohr, T. G., Günther, R. W., & Schaller, S. (2003) · Investigative Radiology · doi:10.1097/01.rli.0000086495.96457.54 · Cited by 227
“A relevant problem of projection interpolation algorithms is the creation of extra artifacts, typically arising if other high attenuation objects like bone are present in the field of view.(9) Depending on the precision for the detection of metal components, osseous structures are sometimes detected and treated like m…”
BackgroundA pragmatic approach to metal artifact reduction in CT: merging of metal artifact reduced images
Kalender, W. A., & Watzke, O. (2004) · European Radiology · doi:10.1007/s00330-004-2263-y · Cited by 209
“Despite good results for some applications, only one of these methods was temporarily implemented in a commercial scanner (namely [9] in the Siemens SOMATOM from 1987 to 1990).”
MethodSelf-citationADN: Artifact Disentanglement Network for Unsupervised Metal Artifact Reduction
Liao, H., Lin, W.-A., Zhou, S. K., & Luo, J. (2020) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2019.2933425 · Cited by 206
“Two of the compared methods are conventional methods: LI [2] and NMAR [3].”
BackgroundMethodLemmens, C., Faul, D., & Nuyts, J. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.929103 · Cited by 194
Metal artifact reduction in x‐ray computed tomography (CT) by constrained optimization
Zhang, X., Wang, J., & Xing, L. (2011) · Medical Physics · doi:10.1118/1.3533711 · Cited by 165
Zhou, C., Zhao, Y. E., Luo, S., Shi, H., li, L., Zheng, L., Zhang, L. J., & Lu, G. (2011) · Academic Radiology · doi:10.1016/j.acra.2011.05.009 · Cited by 161
Metadata
- Authors
- Kalender, W. A., Hebel, R., & Ebersberger, J.
- Venue
- Radiology
- Published
- 1987-08
- Volume
- 164
- Issue
- 2
- Pages
- 576-577
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2154129661
- Cited by
- 751
- References
- 2
- FWCI
- 0.93
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.