Intracranial hemorrhage: gradient-echo MR imaging at 1.5 T. Comparison with spin-echo imaging and clinical applications.
The DOI matches its Crossref record.
Abstract
Fifty-seven patients with hemorrhagic intracranial lesions were examined with magnetic resonance (MR) imaging at 1.5 T with use of both spin-echo (SE) and gradient-echo-acquisition (GEA) techniques to assess the clinical applications and limitations of GEA in evaluation of intracranial hemorrhage at high field strength. All GEA images were obtained with a long echo time and short flip angle to emphasize T2*-based contrast. In 30 of 61 cases, GEA images demonstrated more hemorrhagic lesions than SE images. In 14 of 61 cases, GEA images failed to depict the lesion or obscured the specific diagnosis (as depicted by SE MR imaging). The authors believe that GEA imaging in its current form has a limited but definite adjunctive role in the evaluation of intracranial hemorrhage at high field strength.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cerebral microbleeds: a guide to detection and interpretation
Greenberg, S. M., Vernooij, M. W., Cordonnier, C., Viswanathan, A., Al-Shahi Salman, R., Warach, S., Launer, L. J., Van Buchem, M. A., & Breteler, M. M. (2009) · The Lancet Neurology · doi:10.1016/s1474-4422(09)70013-4 · Cited by 1,798
Cordonnier, C., Al-Shahi Salman, R., & Wardlaw, J. (2007) · Brain · doi:10.1093/brain/awl387 · Cited by 703
“GRE T 2-weighted sequences are more sensitive to haemosiderin than T2-weighted spin echo sequences (Atlas et al., 1988).”
BackgroundMethodCerebral amyloid angiopathy in the elderly
Viswanathan, A., & Greenberg, S. M. (2011) · Annals of Neurology · doi:10.1002/ana.22516 · Cited by 643
(1994) · American Journal of Psychiatry · doi:10.1176/ajp.151.10.1430 · Cited by 556
Hemorrhage Burden Predicts Recurrent Intracerebral Hemorrhage After Lobar Hemorrhage
Greenberg, S. M., Eng, J. A., Ning, M., Smith, E. E., & Rosand, J. (2004) · Stroke · doi:10.1161/01.str.0000126807.69758.0e · Cited by 507
Tong, K. A., Ashwal, S., Holshouser, B. A., Shutter, L. A., Herigault, G., Haacke, E. M., & Kido, D. K. (2003) · Radiology · doi:10.1148/radiol.2272020176 · Cited by 429
Clinical applications of neuroimaging with susceptibility‐weighted imaging
Sehgal, V., Delproposto, Z., Haacke, E. M., Tong, K. A., Wycliffe, N., Kido, D. K., Xu, Y., Neelavalli, J., Haddar, D., & Reichenbach, J. R. (2005) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.20404 · Cited by 427
Charidimou, A., Linn, J., Vernooij, M. W., Opherk, C., Akoudad, S., Baron, J.-C., Greenberg, S. M., Jäger, H. R., & Werring, D. J. (2015) · Brain · doi:10.1093/brain/awv162 · Cited by 385
Cerebral microbleeds on MRI: Prevalence, associations, and potential clinical implications
Koennecke, H.-C. (2006) · Neurology · doi:10.1212/01.wnl.0000194266.55694.1e · Cited by 373
MRI evidence of past cerebral microbleeds in a healthy elderly population
Roob, G., Schmidt, R., Kapeller, P., Lechner, A., Hartung, H.-P., & Fazekas, F. (1999) · Neurology · doi:10.1212/wnl.52.5.991 · Cited by 370
Diffuse axonal injury in children: Clinical correlation with hemorrhagic lesions
Tong, K. A., Ashwal, S., Holshouser, B. A., Nickerson, J. P., Wall, C. J., Shutter, L. A., Osterdock, R. J., Haacke, E. M., & Kido, D. (2004) · Annals of Neurology · doi:10.1002/ana.20123 · Cited by 346
Viswanathan, A., & Chabriat, H. (2006) · Stroke · doi:10.1161/01.str.0000199847.96188.12 · Cited by 315
Amyloid Angiopathy–Related Vascular Cognitive Impairment
Greenberg, S. M., Gurol, M. E., Rosand, J., & Smith, E. E. (2004) · Stroke · doi:10.1161/01.str.0000143224.36527.44 · Cited by 298
MRI Features of Intracerebral Hemorrhage Within 2 Hours From Symptom Onset
Linfante, I., Llinas, R. H., Caplan, L. R., & Warach, S. (1999) · Stroke · doi:10.1161/01.str.30.11.2263 · Cited by 296
Tanaka, A., Ueno, Y., Nakayama, Y., Takano, K., & Takebayashi, S. (1999) · Stroke · doi:10.1161/01.str.30.8.1637 · Cited by 293
Cerebral Microbleeds in CADASIL: A Gradient-Echo Magnetic Resonance Imaging and Autopsy Study
Dichgans, M., Holtmannspötter, M., Herzog, J., Peters, N., Bergmann, M., & Yousry, T. A. (2002) · Stroke · doi:10.1161/hs0102.100885 · Cited by 293
Schrag, M., McAuley, G., Pomakian, J., Jiffry, A., Tung, S., Mueller, C., Vinters, H. V., Haacke, E. M., Holshouser, B., Kido, D., et al. (2010) · Acta Neuropathologica · doi:10.1007/s00401-009-0615-z · Cited by 289
Greenberg, S. M., Briggs, M. E., Hyman, B. T., Kokoris, G. J., Takis, C., Kanter, D. S., Kase, C. S., & Pessin, M. S. (1996) · Stroke · doi:10.1161/01.str.27.8.1333 · Cited by 259
Spatial clustering of hemorrhages in probable cerebral amyloid angiopathy
Rosand, J., Muzikansky, A., Kumar, A., Wisco, J. J., Smith, E. E., Betensky, R. A., & Greenberg, S. M. (2005) · Annals of Neurology · doi:10.1002/ana.20596 · Cited by 244
Detection of Hyperacute Primary Intraparenchymal Hemorrhage by Magnetic Resonance Imaging
Patel, M. R., Edelman, R. R., & Warach, S. (1996) · Stroke · doi:10.1161/01.str.27.12.2321 · Cited by 242
Cerebral Microbleeds: A Review of Clinical, Genetic, and Neuroimaging Associations
Yates, P. A., Villemagne, V. L., Ellis, K. A., Desmond, P. M., Masters, C. L., & Rowe, C. C. (2014) · Frontiers in Neurology · doi:10.3389/fneur.2013.00205 · Cited by 231
“These sequences provide high contrast between brain parenchyma and paramagnetic material, such as deoxyhemoglobin, superparamagnetic hemosiderin, and diamagnetic calcium (27, 28), and are capable of detecting bleeding from vessels as small as 200 μm in diameter (29).”
BackgroundFrequency and Location of Microbleeds in Patients With Primary Intracerebral Hemorrhage
Roob, G., Lechner, A., Schmidt, R., Flooh, E., Hartung, H.-P., & Fazekas, F. (2000) · Stroke · doi:10.1161/01.str.31.11.2665 · Cited by 210
Viswanathan, A. (2006) · Brain · doi:10.1093/brain/awl177 · Cited by 205
“…2003) Defined as rounded foci of <5 mm in size that appear hypointense and distinct from vascular flow voids, leptomeningeal haemosiderosis, or non-haemorrhagic subcortical mineralization (Fazekas et al., 1999; Greenberg et al., 2004), CM can be sensitively imaged by GE MR (Atlas et al., 1988).”
BackgroundClinical applications of susceptibility weighted MR imaging of the brain – a pictorial review
Thomas, B., Somasundaram, S., Thamburaj, K., Kesavadas, C., Gupta, A. K., Bodhey, N. K., & Kapilamoorthy, T. R. (2008) · Neuroradiology · doi:10.1007/s00234-007-0316-z · Cited by 180
“T2*GRE images enable a better detection of the hemorrhage than conventional MRI techniques [33].”
BackgroundDe Reuck, J., Auger, F., Cordonnier, C., Deramecourt, V., Durieux, N., Pasquier, F., Bordet, R., Maurage, C. A., & Leys, D. (2011) · Cerebrovascular Diseases · doi:10.1159/000324391 · Cited by 76
Metadata
- Authors
- Atlas, S. W., Mark, A. S., Grossman, R. I., & Gomori, J. M.
- Venue
- Radiology
- Published
- 1988-09
- Volume
- 168
- Issue
- 3
- Pages
- 803-807
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2061549913
- Cited by
- 259
- References
- 0
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.