The DOI matches its Crossref record.
Quantification of regional cerebral blood flow and volume with dynamic susceptibility contrast-enhanced MR imaging.
Abstract
PURPOSE: Quantification of regional cerebral blood flow (rCBF) and volume (rCBV) with dynamic magnetic resonance (MR) imaging. MATERIALS AND METHODS: After bolus administration of a paramagnetic contrast medium, rapid T2*-weighted gradient-echo images of two sections were acquired for the simultaneous creation of concentration-time curves in the brain-feeding arteries and in brain tissue. Absolute rCBF and rCBV values were determined for gray and white brain matter in 12 subjects with use of principles of the indicator dilution theory. RESULTS: The mean rCBF value in gray matter was 69.7 mL/min +/- 29.7 per 100 g tissue and in white matter, 33.6 mL/min +/- 11.5 per 100 g tissue; the average rCBV was 8.0 mL +/- 3.1 per 100 g tissue and 4.2 mL +/- 1.0 per 100 g tissue, respectively. An age-related decrease in rCBF and rCBV for gray and white matter was observed. CONCLUSION: Preliminary data demonstrate that the proposed technique allows the quantification of rCBF and rCBV. Although the results are in good agreement with data from positron emission tomography studies, further evaluation is needed to establish the validity of method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Neuroimaging and Early Diagnosis of Alzheimer Disease: A Look to the Future
Petrella, J. R., Coleman, R. E., & Doraiswamy, P. M. (2003) · Radiology · doi:10.1148/radiol.2262011600 · Cited by 427
Methodology of brain perfusion imaging
Barbier, E. L., Lamalle, L., & Décorps, M. (2001) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1073 · Cited by 404
Yarkoni, T., Barch, D. M., Gray, J. R., Conturo, T. E., & Braver, T. S. (2009) · PLoS ONE · doi:10.1371/journal.pone.0004257 · Cited by 312
Law, M., Saindane, A. M., Ge, Y., Babb, J. S., Johnson, G., Mannon, L. J., Herbert, J., & Grossman, R. I. (2004) · Radiology · doi:10.1148/radiol.2313030996 · Cited by 242
Wenz, F., Rempp, K., Brix, G., Knopp, M. V., Gückel, F., Heß, T., & van Kaick, G. (1996) · Magnetic Resonance Imaging · doi:10.1016/0730-725x(95)02058-2 · Cited by 57
Microbubbles as a novel contrast agent for brain MRI
Cheung, J. S., Chow, A. M., Guo, H., & Wu, E. X. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.037 · Cited by 36
Neonatal hemodynamics: Monitoring, data acquisition and analysis
Soleymani, S., Borzage, M., Noori, S., & Seri, I. (2012) · Expert Review of Medical Devices · doi:10.1586/erd.12.32 · Cited by 23
Metadata
- Authors
- Rempp, K. A., Brix, G., Wenz, F., Becker, C. R., Gückel, F., & Lorenz, W. J.
- Venue
- Radiology
- Published
- 1994-12
- Volume
- 193
- Issue
- 3
- Pages
- 637-641
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2140464965
- Cited by
- 639
- References
- 0
- FWCI
- 12.25
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.