Perfusion CT of the brain: diagnostic approach for early detection of ischemic stroke.
The DOI matches its Crossref record.
Abstract
PURPOSE: To determine the value of perfusion computed tomography (CT) in a clinical study of patients with stroke and compare the results with single photon emission CT (SPECT) findings. MATERIALS AND METHODS: Perfusion CT was performed within 6 hours of symptom onset in 32 patients with possible stroke. Cerebral blood volume (CBV), cerebral blood flow (CBF), and time to peak contrast material enhancement were calculated on the basis of the CT results. Cerebral SPECT was also performed in a subgroup of 18 patients. Perfusion CT and SPECT findings were compared in a lesion-by-lesion analysis. Perfusion CT results were compared with follow-up CT and magnetic resonance imaging findings. RESULTS: Areas of reduced CBF were detected with the aid of perfusion CT in 25 of 28 patients with a proved infarct (sensitivity, 89%). The results of the CBF maps corresponded well to SPECT findings in 13 (81%) of 16 patients, but ischemia was located outside the scanning level in the other three patients and was therefore missed. Perfusion CT revealed various changes in CBF, CBV, and time to peak enhancement in ischemic territories. CONCLUSION: Perfusion CT not only allows early detection of cerebral ischemia but also yields valuable information about the extent of perfusion disturbances.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Higashida, R. T., & Furlan, A. J. (2003) · Stroke · doi:10.1161/01.str.0000082721.62796.09 · Cited by 1,543
Wintermark, M., Reichhart, M., Thiran, J., Maeder, P., Chalaron, M., Schnyder, P., Bogousslavsky, J., & Meuli, R. (2002) · Annals of Neurology · doi:10.1002/ana.10136 · Cited by 530
Latchaw, R. E., Alberts, M. J., Lev, M. H., Connors, J. J., Harbaugh, R. E., Higashida, R. T., Hobson, R., Kidwell, C. S., Koroshetz, W. J., Mathews, V., et al. (2009) · Stroke · doi:10.1161/strokeaha.108.192616 · Cited by 452
Perfusion CT: a worthwhile enhancement?
Miles, K. A., & Griffiths, M. R. (2003) · The British Journal of Radiology · doi:10.1259/bjr/13564625 · Cited by 392
Cerebral Perfusion CT: Technique and Clinical Applications
Hoeffner, E. G., Case, I., Jain, R., Gujar, S. K., Shah, G. V., Deveikis, J. P., Carlos, R. C., Thompson, B. G., Harrigan, M. R., & Mukherji, S. K. (2004) · Radiology · doi:10.1148/radiol.2313021488 · Cited by 384
Muir, K. W., Buchan, A., von Kummer, R., Rother, J., & Baron, J.-C. (2006) · The Lancet Neurology · doi:10.1016/s1474-4422(06)70545-2 · Cited by 361
Wintermark, M., Reichhart, M., Cuisenaire, O., Maeder, P., Thiran, J.-P., Schnyder, P., Bogousslavsky, J., & Meuli, R. (2002) · Stroke · doi:10.1161/01.str.0000023579.61630.ac · Cited by 345
State-of-the-Art Imaging of Acute Stroke
Srinivasan, A., Goyal, M., Azri, F. A., & Lum, C. (2006) · RadioGraphics · doi:10.1148/rg.26si065501 · Cited by 335
Latchaw, R. E., Yonas, H., Hunter, G. J., Yuh, W. T. C., Ueda, T., Sorensen, A. G., Sunshine, J. L., Biller, J., Wechsler, L., Higashida, R., et al. (2003) · Stroke · doi:10.1161/01.str.0000064840.99271.9e · Cited by 319
Lev, M. H., Segal, A. Z., Farkas, J., Hossain, S. T., Putman, C., Hunter, G. J., Budzik, R., Harris, G. J., Buonanno, F. S., Ezzeddine, M. A., et al. (2001) · Stroke · doi:10.1161/hs0901.095680 · Cited by 316
Schramm, P., Schellinger, P. D., Klotz, E., Kallenberg, K., Fiebach, J. B., Külkens, S., Heiland, S., Knauth, M., & Sartor, K. (2004) · Stroke · doi:10.1161/01.str.0000131271.54098.22 · Cited by 312
Self-citationKoenig, M., Kraus, M., Theek, C., Klotz, E., Gehlen, W., & Heuser, L. (2001) · Stroke · doi:10.1161/01.str.32.2.431 · Cited by 264
Self-citationKlotz, E., & König, M. (1999) · European Journal of Radiology · doi:10.1016/s0720-048x(99)00009-1 · Cited by 234
“1 ml/min per 100 ml for white matter [13].”
BackgroundMethodResultInfluentialSelf-citationComprehensive Imaging of Ischemic Stroke with Multisection CT
Tomandl, B. F., Klotz, E., Handschu, R., Stemper, B., Reinhardt, F., Huk, W. J., Eberhardt, K. E., & Fateh-Moghadam, S. (2003) · RadioGraphics · doi:10.1148/rg.233025036 · Cited by 217
Self-citationComputed Tomography: Revolutionizing the Practice of Medicine for 40 Years
Rubin, G. D. (2014) · Radiology · doi:10.1148/radiol.14141356 · Cited by 197
Radiation dose reduction in perfusion CT imaging of the brain: A review of the literature
Othman, A. E., Afat, S., Brockmann, M. A., Nikoubashman, O., Brockmann, C., Nikolaou, K., & Wiesmann, M. (2016) · Journal of Neuroradiology · doi:10.1016/j.neurad.2015.06.003 · Cited by 50
Metadata
- Authors
- Koenig, M., Klotz, E., Luka, B., Venderink, D. J., Spittler, J. F., & Heuser, L.
- Venue
- Radiology
- Published
- 1998-10
- Volume
- 209
- Issue
- 1
- Pages
- 85-93
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2128797504
- Cited by
- 320
- References
- 0
- FWCI
- 10.80
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.