CoChat

Complications of Total Hip Arthroplasty: MR Imaging—Initial Experience

White, Lawrence M., Kim, Jae K., Mehta, Mitesh, Merchant, Naeem, Schweitzer, Mark E., Morrison, William B., Hutchison, Carol R., Gross, Allan E. · 2000 · Radiology
Cited by 226

The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.

Abstract

PURPOSE: To investigate the use of standard magnetic resonance (MR) imaging sequences with simple parameter modifications for the detection and characterization of total hip arthroplasty (THA) complications. MATERIALS AND METHODS: An initial phantom study was performed with cobalt-chrome and titanium prostheses to establish the imaging parameters for a subsequent clinical study. In the clinical study, coronal and transverse MR imaging of 14 THA prostheses was performed before and after intravenous contrast material administration in 12 patients who were being considered for revision arthroplasty. The images were reviewed for evidence of juxtaarticular or periprosthetic abnormalities, patterns of contrast enhancement, and quality of periprosthetic tissue depiction. RESULTS: Phantom study results showed improved periprosthetic tissue depiction with use of thin sections, increased frequency-encoding gradient strength, and fast spin-echo sequences. The clinical study results demonstrated periprosthetic abnormalities in 11 cases: mechanical loosening in two cases (including one case with an associated periprosthetic fracture); granulomatosis, eight; and infection, one. In 100% of cases, tissue depiction around the femoral component was judged to be of "diagnostic quality." Tissue depiction around the acetabular component was of diagnostic quality in five (36%) cases. In all seven surgically confirmed cases, a correct diagnosis was made preoperatively with MR imaging. CONCLUSION: By using simple modifications to standard MR imaging sequences, diagnostic-quality MR imaging of THA complications can be performed, particularly around the femoral prosthetic stem.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.215.1.r00ap11254

Cites

10 of 10 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 10 references

Cited by

Metadata

Authors
White, L. M., Kim, J. K., Mehta, M., Merchant, N., Schweitzer, M. E., Morrison, W. B., Hutchison, C. R., & Gross, A. E.
Venue
Radiology
Published
2000-04
Volume
215
Issue
1
Pages
254-262
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2009034192
Cited by
226
References
10
FWCI
6.15
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.