Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 180

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Multiple Sclerosis: Magnetization Transfer MR Imaging of White Matter before Lesion Appearance on T2-weighted Images

Pike, G. Bruce, De Stefano, Nicola, Narayanan, Sridar, Worsley, Keith J., Pelletier, Daniel, Francis, Gordon S., Antel, Jack P., Arnold, Douglas L.·2000·Radiology

Abstract

PURPOSE: To determine the evolution of magnetization transfer (MT) in white matter regions before and after plaque development in patients with multiple sclerosis (MS). MATERIALS AND METHODS: In a 5-year longitudinal evaluation, 30 patients with MS underwent conventional magnetic resonance (MR) imaging, MT MR imaging, and clinical assessment. Cross-sectional data in 12 healthy subjects were also collected. Semiautomated lesion classification with use of T2-weighted MR images was used to measure the time course of the MT ratio (calculated with MR data acquired without and with MT saturation) in every voxel and to help analyze the relationship with the status of lesions depicted on T2-weighted images. RESULTS: There was a significant (P <.001) temporal decline in lesion MT ratio after lesion appearance on T2-weighted images. A significant (P <. 001) progressive decline in MT ratio was also present in voxels that later became lesions, prior to initial detection on T2-weighted images. Even 1(1/2) years prior to lesion appearance, the MT ratio (33.3%) in regions destined to become such lesions was significantly (P <.001) lower than that in both white matter in healthy subjects (41.3%) and other normal-appearing white matter in patients with MS (38.1%). CONCLUSION: The MT ratio reveals progressive focal abnormalities in MS that antedate by up to 2 years the appearance of lesions on T2-weighted MR images.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1148/radiology.215.3.r00jn02824

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 180

Metadata

Authors
Pike, G. B., De Stefano, N., Narayanan, S., Worsley, K. J., Pelletier, D., Francis, G. S., Antel, J. P., & Arnold, D. L.
Venue
Radiology
Published
2000-06
Volume
215
Issue
3
Pages
824-830
ISSN
  • 0033-8419 (ISSN-L)
  • 1527-1315
OpenAlex
W2151048095
Cited by
180
References
4
FWCI
6.65
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Multiple Sclerosis: Magnetization Transfer MR Imaging of White Matter before Lesion Appearance on T2-weighted Images. https://app.cochat.ai/papers/10.1148/radiology.215.3.r00jn02824
The paper
Pike, G. B., De Stefano, N., Narayanan, S., Worsley, K. J., Pelletier, D., Francis, G. S., Antel, J. P., & Arnold, D. L. (2000). Multiple Sclerosis: Magnetization Transfer MR Imaging of White Matter before Lesion Appearance on T2-weighted Images. Radiology. https://doi.org/10.1148/radiology.215.3.r00jn02824

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.