Focal Liver Lesions: Evaluation of the Efficacy of Gadobenate Dimeglumine in MR Imaging—A Multicenter Phase III Clinical Study
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
PURPOSE: To evaluate gadobenate dimeglumine (Gd-BOPTA) for dynamic and delayed magnetic resonance (MR) imaging of focal liver lesions. MATERIALS AND METHODS: In 126 of 214 patients, MR imaging was performed before Gd-BOPTA administration, immediately after bolus administration of a 0.05- mmol/kg dose of Gd-BOPTA, and 60-120 minutes after an additional intravenously infused 0.05-mmol/kg dose. In 88 patients, imaging was performed before and 60-120 minutes after a single, intravenously infused 0.1-mmol/kg dose. T1- and T2-weighted spin-echo and T1-weighted gradient-echo images were acquired. On-site and blinded off-site reviewers prospectively evaluated all images. Intraoperative ultrasonography, computed tomography (CT) during arterial portography, and/or CT with iodized oil served as the reference methods in 110 patients. RESULTS: Significantly more lesions were detected on combined pre- and postcontrast images compared with on precontrast images alone (P <. 01). All reviewers reported a decreased mean size of the smallest detected lesion and improved lesion conspicuity on postcontrast images. All on-site reviewers and two off-site reviewers reported increased overall diagnostic confidence (P <.01). Additional lesion characterization information was provided on up to 109 (59%) of 184 delayed images and for up to 50 (42%) of 118 patients in whom dynamic images were assessed. Gd-BOPTA would have helped change the diagnosis in 99 (47%) of 209 cases and affected patient treatment in 408 (23%) of 209 cases. CONCLUSION: Gd-BOPTA increases liver lesion conspicuity and detectability and aids in the characterization of lesions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Surgical anatomy and anatomical surgery of the liver
Bismuth, H. (1982) · World Journal of Surgery · doi:10.1007/bf01656368 · Cited by 791
Hamm, B., Staks, T., Mühler, A., Bollow, M., Taupitz, M., Frenzel, T., Wolf, K. J., Weinmann, H. J., & Lange, L. (1995) · Radiology · doi:10.1148/radiology.195.3.7754011 · Cited by 575
Self-citationHeiken, J. P., Weyman, P. J., Lee, J. K., Balfe, D. M., Picus, D., Brunt, E. M., & Flye, M. W. (1989) · Radiology · doi:10.1148/radiology.171.1.2538862 · Cited by 315
Phase II clinical evaluation of Gd-EOB-DTPA: dose, safety aspects, and pulse sequence.
Reimer, P., Rummeny, E. J., Shamsi, K., Balzer, T., Daldrup, H. E., Tombach, B., Hesse, T., Berns, T., & Peters, P. E. (1996) · Radiology · doi:10.1148/radiology.199.1.8633143 · Cited by 309
Self-citationClinical Features and Long-term Prognosis
Nagao, T., GOTO, S., Kawano, N., Inoue, S., MIZUTA, T., Morioka, Y., & Omori, Y. (1987) · Annals of Surgery · doi:10.1097/00000658-198701000-00006 · Cited by 300
Iron oxide-enhanced MR imaging of the liver and spleen: review of the first 5 years
Ferrucci, J. T., & Stark, D. D. (1990) · American Journal of Roentgenology · doi:10.2214/ajr.155.5.2120963 · Cited by 279
Takayasu, K., Moriyama, N., Muramatsu, Y., Makuuchi, M., Hasegawa, H., Okazaki, N., & Hirohashi, S. (1990) · American Journal of Roentgenology · doi:10.2214/ajr.155.1.1693808 · Cited by 266
Spinazzi, A., Lorusso, V., Pirovano, G., & Kirchin, M. (1999) · Academic Radiology · doi:10.1016/s1076-6332(99)80451-6 · Cited by 204
Self-citationHamm, B., Thoeni, R. F., Gould, R. G., Bernardino, M. E., Lüning, M., Saini, S., Mahfouz, A. E., Taupitz, M., & Wolf, K. J. (1994) · Radiology · doi:10.1148/radiology.190.2.8284392 · Cited by 204
Self-citationFocal liver lesions: MR imaging with Mn-DPDP--initial clinical results in 40 patients.
Hamm, B., Vogl, T. J., Branding, G., Schnell, B., Taupitz, M., Wolf, K. J., & Lissner, J. (1992) · Radiology · doi:10.1148/radiology.182.1.1309218 · Cited by 175
Self-citationMultiHance clinical pharmacology: Biodistribution and MR enhancement of the liver
Spinazzi, A., Lorusso, V., Pirovano, G., Taroni, P., Kirchin, M. A., & Davies, A. (1998) · Academic Radiology · doi:10.1016/s1076-6332(98)80069-x · Cited by 80
Self-citationRummeny, E., Wernecke, K., Saini, S., Vassallo, P., Wiesmann, W., Oestmann, J. W., Kivelitz, D. E., Reers, B., Reiser, M., & Peters, P. E. (1992) · Radiology · doi:10.1148/radiology.182.3.1535912 · Cited by 69
Self-citationMergo, P. J., Engelken, J. D., Helmberger, T. K., & Ros, P. R. (1998) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.1880080511 · Cited by 45
Ferrucci, J. T. (1994) · Radiologic Clinics of North America · doi:10.1016/s0033-8389(22)00336-0 · Cited by 43
Reimer, P., Tombach, B., Daldrup-Link, H. E., Hesse, T., Sander, G., Balzer, T., Shamsi, K., Berns, T., Rummeny, E. J., & Peters, P. E. (1996) · Der Radiologe · doi:10.1007/s001170050049 · Cited by 31
Self-citationRockette, H. E., King, J. L., Thaete, F. L., Fuhrman, C. R., Slifko, R. M., & Gur, D. (1998) · Academic Radiology · doi:10.1016/s1076-6332(98)80127-x · Cited by 18
Cited by
Quaia, E., Calliada, F., Bertolotto, M., Rossi, S., Garioni, L., Rosa, L., & Pozzi-Mucelli, R. (2004) · Radiology · doi:10.1148/radiol.2322031401 · Cited by 479
Huppertz, A., Balzer, T., Blakeborough, A., Breuer, J., Giovagnoni, A., Heinz-Peer, G., Laniado, M., Manfredi, R. M., Mathieu, D. G., Mueller, D., et al. (2004) · Radiology · doi:10.1148/radiol.2301020269 · Cited by 396
Self-citationHepatobiliary-specific MR Contrast Agents: Role in Imaging the Liver and Biliary Tree
Seale, M. K., Catalano, O. A., Saini, S., Hahn, P. F., & Sahani, D. V. (2009) · RadioGraphics · doi:10.1148/rg.296095515 · Cited by 388
For the European EOB-study group, Hammerstingl, R., Huppertz, A., Breuer, J., Balzer, T., Blakeborough, A., Carter, R., Fusté, L. C., Heinz-Peer, G., Judmaier, W., et al. (2008) · European Radiology · doi:10.1007/s00330-007-0716-9 · Cited by 384
Self-citationGrazioli, L., Morana, G., Kirchin, M. A., & Schneider, G. (2005) · Radiology · doi:10.1148/radiol.2361040338 · Cited by 354
Self-citation
Metadata
- Authors
- Petersein, J., Spinazzi, A., Giovagnoni, A., Soyer, P., Terrier, F., Lencioni, R., Bartolozzi, C., Grazioli, L., Chiesa, A., Manfredi, R., Marano, P., Van Persijn van Meerten, E. L., Bloem, J. L., Petre, C., Marchal, G., Greco, A., McNamara, M. T., Heuck, A., Reiser, M., Laniado, M., Claussen, C., Daldrup, H. E., Rummeny, E., Kirchin, M. A., Pirovano, G., & Hamm, B.
- Venue
- Radiology
- Published
- 2000-06
- Volume
- 215
- Issue
- 3
- Pages
- 727-736
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2137815374
- Cited by
- 187
- References
- 16
- FWCI
- 9.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.