An Improved MR Imaging Technique for the Visualization of Myocardial Infarction
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
PURPOSE: To design a segmented inversion-recovery turbo fast low-angle shot (turboFLASH) magnetic resonance (MR) imaging pulse sequence for the visualization of myocardial infarction, compare this technique with other MR imaging approaches in a canine model of ischemic injury, and evaluate its utility in patients with coronary artery disease. MATERIALS AND METHODS: Six dogs and 18 patients were examined. In dogs, infarction was produced and images were acquired by using 10 different pulse sequences. In patients, the segmented turboFLASH technique was used to acquire contrast material-enhanced images 19 days +/- 7 (SD) after myocardial infarction. RESULTS: Myocardial regions of increased signal intensity were observed in all animals and patients at imaging. With the postcontrast segmented turboFLASH sequence, the signal intensity of the infarcted myocardium was 1,080% +/- 214 higher than that of the normal myocardium in dogs-nearly twice that of the next best sequence tested and approximately 10-fold greater than that in previous reports. All 18 patients with myocardial infarction demonstrated high signal intensity at imaging. On average, the signal intensity of the high-signal-intensity regions in patients was 485% +/- 43 higher than that of the normal myocardium. CONCLUSION: The segmented inversion-recovery turboFLASH sequence produced the greatest differences in regional myocardial signal intensity in animals. Application of this technique in patients with infarction substantially improved differentiation between injured and normal regions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Design and Analysis of Clinical Experiments
Fleiss, J. L. (1999) · Wiley eBooks · doi:10.1002/9781118032923 · Cited by 4,819
Kim, R. J., Fieno, D. S., Parrish, T. B., Harris, K., Chen, E.-L., Simonetti, O., Bundy, J., Finn, J. P., Klocke, F. J., & Judd, R. M. (1999) · Circulation · doi:10.1161/01.cir.100.19.1992 · Cited by 2,581
Self-citation"Black blood" T2-weighted inversion-recovery MR imaging of the heart.
Simonetti, O. P., Finn, J. P., White, R. D., Laub, G., & Henry, D. A. (1996) · Radiology · doi:10.1148/radiology.199.1.8633172 · Cited by 560
Self-citationRochitte, C. E., Lima, J. A. C., Bluemke, D. A., Reeder, S. B., McVeigh, E. R., Furuta, T., Becker, L. C., & Melin, J. A. (1998) · Circulation · doi:10.1161/01.cir.98.10.1006 · Cited by 494
Lima, J. A. C., Judd, R. M., Bazille, A., Schulman, S. P., Atalar, E., & Zerhouni, E. A. (1995) · Circulation · doi:10.1161/01.cir.92.5.1117 · Cited by 474
Self-citationJudd, R. M., Lugo-Olivieri, C. H., Arai, M., Kondo, T., Croisille, P., Lima, J. A. C., Mohan, V., Becker, L. C., & Zerhouni, E. A. (1995) · Circulation · doi:10.1161/01.cir.92.7.1902 · Cited by 463
Self-citationFirst-pass cardiac perfusion: evaluation with ultrafast MR imaging.
Atkinson, D. J., Burstein, D., & Edelman, R. R. (1990) · Radiology · doi:10.1148/radiology.174.3.2305058 · Cited by 359
Early Contrast-Enhanced MRI Predicts Late Functional Recovery After Reperfused Myocardial Infarction
Rogers, W. J., Kramer, C. M., Geskin, G., Hu, Y.-L., Theobald, T. M., Vido, D. A., Petruolo, S., & Reichek, N. (1999) · Circulation · doi:10.1161/01.cir.99.6.744 · Cited by 244
Roos, A., van Rossum, A. C., van der Wall, E. E., Postema, S., Doornbos, J., Matheijssen, N. A. A., van Dijkman, P. R. M., Visser, F. C., & van Voorthuisen, A. E. (1989) · Radiology · doi:10.1148/radiology.172.3.2772179 · Cited by 152
Segmented turboFLASH: method for breath-hold MR imaging of the liver with flexible contrast.
Edelman, R. R., Wallner, B., Singer, A., Atkinson, D. J., & Saini, S. (1990) · Radiology · doi:10.1148/radiology.177.2.2171014 · Cited by 142
Noninvasive Measurements of Infarct Size After Thrombolysis With a Necrosis-Avid MRI Contrast Agent
Pislaru, S. V., Ni, Y., Pislaru, C., Bosmans, H., Miao, Y., Bogaert, J. G., Dymarkowski, S., Semmler, W., Marchal, G., & de Werf, F. V. (1999) · Circulation · doi:10.1161/01.cir.99.5.690 · Cited by 87
Occlusive and reperfused myocardial infarcts: effect of Gd-DTPA on ECG-gated MR imaging.
Tscholakoff, D., Higgins, C. B., Sechtem, U., & McNamara, M. T. (1986) · Radiology · doi:10.1148/radiology.160.2.3726135 · Cited by 76
Cited by
Kim, R. J., Wu, E., Rafael, A., Chen, E.-L., Parker, M. A., Simonetti, O., Klocke, F. J., Bonow, R. O., & Judd, R. M. (2000) · New England Journal of Medicine · doi:10.1056/nejm200011163432003 · Cited by 3,306
Self-citationCardiovascular Magnetic Resonance in Myocarditis: A JACC White Paper
Friedrich, M. G., Sechtem, U., Schulz-Menger, J., Holmvang, G., Alakija, P., Cooper, L. T., White, J. A., Abdel-Aty, H., Gutberlet, M., Prasad, S., et al. (2009) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2009.02.007 · Cited by 2,509
Makkar, R. R., Smith, R. R., Cheng, K., Malliaras, K., Thomson, L. E., Berman, D., Czer, L. S., Marbán, L., Mendizabal, A., Johnston, P. V., et al. (2012) · The Lancet · doi:10.1016/s0140-6736(12)60195-0 · Cited by 1,422
Modified Look‐Locker inversion recovery (MOLLI) for high‐resolution T1 mapping of the heart
Messroghli, D. R., Radjenovic, A., Kozerke, S., Higgins, D. M., Sivananthan, M. U., & Ridgway, J. P. (2004) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20110 · Cited by 1,349
Wagner, A., Mahrholdt, H., Holly, T. A., Elliott, M. D., Regenfus, M., Parker, M., Klocke, F. J., Bonow, R. O., Kim, R. J., & Judd, R. M. (2003) · The Lancet · doi:10.1016/s0140-6736(03)12389-6 · Cited by 1,307
Self-citation
Metadata
- Authors
- Simonetti, O. P., Kim, R. J., Fieno, D. S., Hillenbrand, H. B., Wu, E., Bundy, J. M., Finn, J. P., & Judd, R. M.
- Venue
- Radiology
- Published
- 2001-01
- Volume
- 218
- Issue
- 1
- Pages
- 215-223
- ISSN
- 0033-8419 (ISSN-L)
- 1527-1315
- OpenAlex
- W2171700197
- Cited by
- 1,358
- References
- 12
- FWCI
- 42.64
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.