The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Photon-counting Detector CT: System Design and Clinical Applications of an Emerging Technology
Open accessAbstract
Photon-counting detector (PCD) CT is an emerging technology that has shown tremendous progress in the last decade. Various types of PCD CT systems have been developed to investigate the benefits of this technology, which include reduced electronic noise, increased contrast-to-noise ratio with iodinated contrast material and radiation dose efficiency, reduced beam-hardening and metal artifacts, extremely high spatial resolution (33 line pairs per centimeter), simultaneous multienergy data acquisition, and the ability to image with and differentiate among multiple CT contrast agents. PCD technology is described and compared with conventional CT detector technology. With the use of a whole-body research PCD CT system as an example, PCD technology and its use for in vivo high-spatial-resolution multienergy CT imaging is discussed. The potential clinical applications, diagnostic benefits, and challenges associated with this technology are then discussed, and examples with phantom, animal, and patient studies are provided. ©RSNA, 2019
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dual- and Multi-Energy CT: Principles, Technical Approaches, and Clinical Applications
McCollough, C. H., Leng, S., Yu, L., & Fletcher, J. G. (2015) · Radiology · doi:10.1148/radiol.2015142631 · Cited by 1,598
Self-citationMaterial differentiation by dual energy CT: initial experience
Johnson, T. R. C., Krauß, B., Sedlmair, M., Grasruck, M., Bruder, H., Morhard, D., Fink, C., Weckbach, S., Lenhard, M., Schmidt, B., et al. (2007) · European Radiology · doi:10.1007/s00330-006-0517-6 · Cited by 1,510
Vision 20/20: Single photon counting x‐ray detectors in medical imaging
Taguchi, K., & Iwanczyk, J. S. (2013) · Medical Physics · doi:10.1118/1.4820371 · Cited by 948
Schlomka, J. P., Roessl, E., Dorscheid, R., Dill, S., Martens, G., Istel, T., Bäumer, C., Herrmann, C., Steadman, R., Zeitler, G., et al. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/15/002 · Cited by 801
Dual-Energy CT: General Principles
Johnson, T. R. C. (2012) · American Journal of Roentgenology · doi:10.2214/ajr.12.9116 · Cited by 631
K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors
Roessl, E., & Proksa, R. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/15/020 · Cited by 558
Atherosclerotic Plaque Composition: Analysis with Multicolor CT and Targeted Gold Nanoparticles
Cormode, D. P., Roessl, E., Thran, A., Skajaa, T., Gordon, R. E., Schlomka, J.-P., Fuster, V., Fisher, E. A., Mulder, W. J. M., Proksa, R., et al. (2010) · Radiology · doi:10.1148/radiol.10092473 · Cited by 479
Gutjahr, R., Halaweish, A. F., Yu, Z., Leng, S., Yu, L., Li, Z., Jorgensen, S. M., Ritman, E. L., Kappler, S., & McCollough, C. H. (2016) · Investigative Radiology · doi:10.1097/rli.0000000000000251 · Cited by 282
Self-citationMulti-Material Decomposition Using Statistical Image Reconstruction for Spectral CT
Long, Y. Q., & Fessler, J. A. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2320284 · Cited by 252
Leng, S., Rajendran, K., Gong, H., Zhou, W., Halaweish, A. F., Henning, A., Kappler, S., Baer, M., Fletcher, J. G., & McCollough, C. H. (2018) · Investigative Radiology · doi:10.1097/rli.0000000000000488 · Cited by 208
Self-citationAbdominal Imaging with Contrast-enhanced Photon-counting CT: First Human Experience
Pourmorteza, A., Symons, R., Sandfort, V., Mallek, M., Fuld, M. K., Henderson, G., Jones, E. C., Malayeri, A. A., Folio, L. R., & Bluemke, D. A. (2016) · Radiology · doi:10.1148/radiol.2016152601 · Cited by 207
Shikhaliev, P. M., & Fritz, S. G. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/7/001 · Cited by 190
Dual Energy CT in Clinical Practice
(2011) · Medical Radiology · doi:10.1007/978-3-642-01740-7 · Cited by 179
An algorithm for constrained one-step inversion of spectral CT data
Barber, R. F., Sidky, E. Y., Schmidt, T. G., & Pan, X. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/10/3784 · Cited by 176
Cormode, D. P., Si-Mohamed, S. A., Bar-Ness, D., Sigovan, M., Naha, P. C., Balegamire, J., Lavenne, F., Coulon, P., Roessl, E., Bartels, M.-B., et al. (2017) · Scientific Reports · doi:10.1038/s41598-017-04659-9 · Cited by 163
Spectroscopic (multi-energy) CT distinguishes iodine and barium contrast material in MICE
ANDERSON, N. G., Butler, A. P. H., Scott, N. J. A., Cook, N. J., Butzer, J. S., Schleich, N., Firsching, M., Grasset, R., de Ruiter, N., Campbell, M., et al. (2010) · European Radiology · doi:10.1007/s00330-010-1768-9 · Cited by 162
Pan, D., Schirra, C. O., Senpan, A., Schmieder, A. H., Stacy, A. J., Roessl, E., Thran, A., Wickline, S. A., Proska, R., & Lanza, G. M. (2012) · ACS Nano · doi:10.1021/nn300392x · Cited by 148
Spectral Photon-counting CT: Initial Experience with Dual–Contrast Agent K-Edge Colonography
Muenzel, D., Bar-Ness, D., Roessl, E., Blevis, I. M., Bartels, M., Fingerle, A. A., Ruschke, S., Coulon, P., Daerr, H., Kopp, F. K., et al. (2016) · Radiology · doi:10.1148/radiol.2016160890 · Cited by 143
Electronic Noise in CT Detectors: Impact on Image Noise and Artifacts
Duan, X., Wang, J., Leng, S., Schmidt, B. T., Allmendinger, T., Grant, K. L. R., Flohr, T. G., & McCollough, C. H. (2013) · American Journal of Roentgenology · doi:10.2214/ajr.12.10234 · Cited by 132
Self-citationSi-Mohamed, S. A., Bar-Ness, D., Sigovan, M., Cormode, D. P., Coulon, P., Coche, E., Vlassenbroek, A., Normand, G., Boussel, L., & Douek, P. (2017) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2017.04.014 · Cited by 128
Low-dose lung cancer screening with photon-counting CT: a feasibility study
Symons, R., Cork, T. E., Sahbaee, P., Fuld, M. K., Kappler, S. G., Folio, L. R., Bluemke, D. A., & Pourmorteza, A. (2016) · Physics in Medicine and Biology · doi:10.1088/1361-6560/62/1/202 · Cited by 120
Spectral CT Reconstruction With Image Sparsity and Spectral Mean
Zhang, Y., Xi, Y., Yang, Q., Cong, W., Zhou, J., & Wang, G. (2016) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2016.2609414 · Cited by 119
Image Reconstruction for Hybrid True-Color Micro-CT
Xu, Q., Yu, H., Bennett, J., He, P., Zainon, R., Doesburg, R., Opie, A. M. T., Walsh, M., Shen, H., Butler, A. P. H., et al. (2012) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2012.2192119 · Cited by 108
Charge sharing in common-grid pixelated CdZnTe detectors
Kim, J. C., Anderson, S. E., Kaye, W., Zhang, F., Zhu, Y., Kaye, S. J., & He, Z. J. (2011) · Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment · doi:10.1016/j.nima.2011.06.038 · Cited by 108
Dangelmaier, J., Bar-Ness, D., Daerr, H., Muenzel, D., Si-Mohamed, S. A., Ehn, S., Fingerle, A. A., Kimm, M. A., Kopp, F. K., Boussel, L., et al. (2018) · European Radiology · doi:10.1007/s00330-017-5252-7 · Cited by 100
Yu, Z., Leng, S., Li, Z., & McCollough, C. H. (2016) · Physics in Medicine and Biology · doi:10.1088/0031-9155/61/18/6707 · Cited by 94
Self-citationToward quantifying the composition of soft tissues by spectral CT with Medipix3
Ronaldson, J. P., Zainon, R., Scott, N. J. A., Gieseg, S. P., Butler, A. P. H., Butler, P. H., & ANDERSON, N. G. (2012) · Medical Physics · doi:10.1118/1.4760773 · Cited by 74
Cai, C., Rodet, T., Legoupil, S., et al. (2013) · Medical Physics · doi:10.1118/1.4820478 · Cited by 69
Weidinger, T., Buzug, T. M., Flohr, T. G., Kappler, S. G., & Stierstorfer, K. (2016) · International Journal of Biomedical Imaging · doi:10.1155/2016/5871604 · Cited by 48
Ghaghada, K. B., Sato, A. F., Starosolski, Z. A., Berg, J., & Vail, D. M. (2016) · PLoS ONE · doi:10.1371/journal.pone.0152718 · Cited by 39
Three dimensional mapping of strontium in bone by dual energy K-edge subtraction imaging
Cooper, D. M. L., Chapman, D., Carter, Y., Wu, Y., Panahifar, A., Britz, H. M., Bewer, B., Zhouping, W., Duke, M. J. M., & Doschak, M. R. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/18/5777 · Cited by 37
High-Resolution CT Vascular Imaging Using Blood Pool Contrast Agents
Annapragada, A., Hoffman, E. A., Divekar, A. A., Karathanasis, E., & Ghaghada, K. B. (2012) · Methodist DeBakey Cardiovascular Journal · doi:10.14797/mdcj-8-1-18 · Cited by 28
Spectral imaging of iodine and gadolinium nanoparticles using dual-energy CT
Badea, C. T., Ghaghada, K. B., Clark, D. P., & Holbrook, M. (2018) · SPIE Medical Imaging: Physics of Medical Imaging · doi:10.1117/12.2293625 · Cited by 11
Cited by
Flohr, T., Petersilka, M., Henning, A., Ulzheimer, S., Ferda, J., & Schmidt, B. (2020) · Physica Medica · doi:10.1016/j.ejmp.2020.10.030 · Cited by 581
Nowak, T., Eberhard, M., Schmidt, B., Frey, D., Distler, O., Saltybaeva, N., Alkadhi, H., & Euler, A. (2021) · Radiology · doi:10.1148/radiol.2020202767 · Cited by 41
Metadata
- Authors
- Leng, S., Bruesewitz, M., Tao, S., Rajendran, K., Halaweish, A. F., Campeau, N. G., Fletcher, J. G., & McCollough, C. H.
- Venue
- RadioGraphics
- Published
- 2019-05
- Volume
- 39
- Issue
- 3
- Pages
- 729-743
- ISSN
- 0271-5333 (ISSN-L)
- 1527-1323
- OpenAlex
- W2943602527
- Cited by
- 545
- References
- 33
- FWCI
- 12.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.