Validation of a patient-specific one-dimensional model of the systemic arterial tree
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
The aim of this study is to develop and validate a patient-specific distributed model of the systemic arterial tree. This model is built using geometric and hemodynamic data measured on a specific person and validated with noninvasive measurements of flow and pressure on the same person, providing thus a patient-specific model and validation. The systemic arterial tree geometry was obtained from MR angiographic measurements. A nonlinear viscoelastic constitutive law for the arterial wall is considered. Arterial wall distensibility is based on literature data and adapted to match the wave propagation velocity of the main arteries of the specific subject, which were estimated by pressure waves traveling time. The intimal shear stress is modeled using the Witzig-Womersley theory. Blood pressure is measured using applanation tonometry and flow rate using transcranial ultrasound and phase-contrast-MRI. The model predicts pressure and flow waveforms in good qualitative and quantitative agreement with the in vivo measurements, in terms of wave shape and specific wave features. Comparison with a generic one-dimensional model shows that the patient-specific model better predicts pressure and flow at specific arterial sites. These results obtained let us conclude that a patient-specific one-dimensional model of the arterial tree is able to predict well pressure and flow waveforms in the main systemic circulation, whereas this is not always the case for a generic one-dimensional model.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chen, C.-H., Nevo, E., Fetics, B., Pak, P. H., Yin, F. C. P., Maughan, W. L., & Kass, D. A. (1997) · Circulation · doi:10.1161/01.cir.95.7.1827 · Cited by 1,307
Aortic input impedance in normal man: relationship to pressure wave forms.
Murgo, J. P., Westerhof, N., Giolma, J. P., & Altobelli, S. A. (1980) · Circulation · doi:10.1161/01.cir.62.1.105 · Cited by 1,014
The dynamic elastic properties of the arterial wall
Bergel, D. H. (1961) · The Journal of Physiology · doi:10.1113/jphysiol.1961.sp006687 · Cited by 904 · cited 8×
“Furthermore, based on Bergel’s (4) data for the thoracic aorta, abdominal aorta, and femoral artery, we assumed that the viscoelastic coefficient, ã, increased linearly as the diameter decreased from the heart to the periphery given by”
BackgroundMethodInfluentialKARAMANOGLU, M., O'ROURKE, M. F., AVOLIO, A. P., & KELLY, R. P. (1993) · European Heart Journal · doi:10.1093/eurheartj/14.2.160 · Cited by 873 · cited 1×
“Sex and age can also be taken into account in a statistical manner, as was done previously for the generalized transfer function (6, 12, 29).”
BackgroundOlufsen, M. S., Peskin, C. S., Kim, W. Y., Pedersen, E. M., Nadim, A., & Larsen, J. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.1326031 · Cited by 862 · cited 1×
“(20), although the study by Olufsen et al.”
BackgroundAnalog studies of the human systemic arterial tree
Westerhof, N., Bosman, F., De Vries, C. J., & Noordergraaf, A. (1969) · Journal of Biomechanics · doi:10.1016/0021-9290(69)90024-4 · Cited by 684 · cited 1×
“(30, 31), arteriosclerosis by Raines et al.”
Validation of a one-dimensional model of the systemic arterial tree
Reymond, P., Merenda, F., Perren, F., Rüfenacht, D., & Stergiopulos, N. (2009) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00037.2009 · Cited by 638 · cited 5×
“Reymond et al. 2009 (23) suggested that future work should be focused on a quantitative validation of the model on a specific subject with the arterial tree constructed based on geometry and elasticity data derived from measurements on the specific person.”
BackgroundResultInfluentialSelf-citationMulti-branched model of the human arterial system
Avolio, A. P. (1980) · Medical & Biological Engineering & Computing · doi:10.1007/bf02441895 · Cited by 517 · cited 1×
“(22), stenoses by many authors (2, 5, 7, 10, 13, 17, 21, 25, 26, 32), anatomical variations of cerebral arteries, arterial occlusion by Alastruey et al.”
BackgroundComputer simulation of arterial flow with applications to arterial and aortic stenoses
Stergiopulos, N., Young, D. F., & Rogge, T. R. (1992) · Journal of Biomechanics · doi:10.1016/0021-9290(92)90060-e · Cited by 511 · cited 1×
“(22), stenoses by many authors (2, 5, 7, 10, 13, 17, 21, 25, 26, 32), anatomical variations of cerebral arteries, arterial occlusion by Alastruey et al.”
BackgroundSelf-citationLatham, R. D., Westerhof, N., Sipkema, P., Rubal, B. J., Reuderink, P., & Murgo, J. P. (1985) · Circulation · doi:10.1161/01.cir.72.6.1257 · Cited by 454 · cited 1×
“Values of PWV reported in the literature (3, 8, 9, 15, 16, 18) for different arteries as a function of the mean arterial lumen diameter were presented.”
Method
Cited by
Kissas, G., Yang, Y., Hwuang, E., Witschey, W. R., Detre, J. A., & Perdikaris, P. (2020) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/j.cma.2019.112623 · Cited by 647
A benchmark study of numerical schemes for one‐dimensional arterial blood flow modelling
Boileau, E., Nithiarasu, P., Blanco, P. J., Müller, L. O., Fossan, F. E., Hellevik, L. R., Donders, W. P., Huberts, W., Willemet, M., & Alastruey, J. (2015) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.2732 · Cited by 209
“An increasing number of recent studies have shown the ability of the 1D formulation to capture the main features of pressure, flow and area waveforms in large human arteries, using in vivo measurements [6, 8, 9, 26, 27], in vitro experiments [28–32] or 3D numerical data [16, 33].”
BackgroundBlanco, P. J., Müller, L. O., & Spence, J. D. (2017) · Stroke and Vascular Neurology · doi:10.1136/svn-2017-000087 · Cited by 202
An Anatomically Detailed Arterial Network Model for One-Dimensional Computational Hemodynamics
Blanco, P. J., Watanabe, S. M., Passos, M. A. R. F., Lemos, P. A., & Feijoo, R. A. (2015) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2364522 · Cited by 163
“From pioneer works studying the basic theoretical ingredients [15]–[19], going through the early developments of topological descriptions of the CVS [20]–[25], subsequent improvements and alternatives [26]–[30], and finally, reaching incontestable in vitro validations and in vivo verifications [31]–[35], as well as in…”
BackgroundMethodA practical approach to parameter estimation applied to model predicting heart rate regulation
Olufsen, M. S., & Ottesen, J. T. (2013) · Journal of Mathematical Biology · doi:10.1007/s00285-012-0535-8 · Cited by 106
Metadata
- Authors
- Reymond, P., Bohraus, Y., Perren, F., Lazeyras, F., & Stergiopulos, N.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2011-09
- Volume
- 301
- Issue
- 3
- Pages
- H1173-H1182
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2104821869
- Cited by
- 210
- References
- 28
- FWCI
- 11.07
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.