The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Single-beat estimation of right ventricular end-systolic pressure-volume relationship
Abstract
Assessement of right ventricular (RV) contractility from end-systolic pressure-volume relationships (ESPVR) is difficult due to problems in measuring RV instantaneous volume and to effects of changes in RV preload or afterload. We therefore investigated in anesthetized dogs whether RV ESPVR and contractility can be determined without measuring RV volume and without changing RV preload or afterload. The maximal RV pressure of isovolumic beats (P max) was predicted from isovolumic portions of RV pressure during ejecting beats and compared with P max measured during the first beat after pulmonary artery clamping. In RV pressure-volume loops obtained from RV pressure and integrated pulmonary arterial flow, end-systolic elastance ( E es) was assessed as the slope of P max-derived ESPVR, pulmonary artery effective elastance ( E a) as the slope of end-diastolic to end-systolic relation, and coupling efficiency as the E es-to- E a ratio ( E es/ E a). Predicted P max correlated with observed P max( r = 0.98 ± 0.02). Dobutamine increased E es from 1.07 to 2.00 mmHg/ml and E es/ E a from 1.64 to 2.49, and propranolol decreased E es/ E a from 1.64 to 0.91 (all P < 0.05). After adrenergic blockade, preload reduction did not affect E es, whereas hypoxia and arterial constriction markedly increased E a and somewhat increased E es due to the Anrep effect. Low preload did not affect E es/ E a and high afterload decreased E es/ E a. In conclusion, in the right ventricle 1) P max can be calculated from normal beats, 2) P max can be used to determine ESPVR without change in load, and 3) P max-derived ESPVR can be used to assess ventricular contractility and ventricular-arterial coupling efficiency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
SUGA, H., SAGAWA, K., & SHOUKAS, A. A. (1973) · Circulation Research · doi:10.1161/01.res.32.3.314 · Cited by 1,502
Effective arterial elastance as index of arterial vascular load in humans.
Kelly, R. P., Ting, C. T., Yang, T. M., Liu, C. P., Maughan, W. L., Chang, M. S., & Kass, D. A. (1992) · Circulation · doi:10.1161/01.cir.86.2.513 · Cited by 829
Sagawa, K. (1981) · Circulation · doi:10.1161/01.cir.63.6.1223 · Cited by 585
Vogel, M., Schmidt, M. R., Kristiansen, S. B., Cheung, M., White, P. A., Sorensen, K., & Redington, A. N. (2002) · Circulation · doi:10.1161/01.cir.0000013773.67850.ba · Cited by 443
Ventricular efficiency predicted by an analytical model
Burkhoff, D., & Sagawa, K. (1986) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1986.250.6.r1021 · Cited by 405
Ventriculoarterial coupling in normal and failing heart in humans.
Asanoi, H., Sasayama, S., & Kameyama, T. (1989) · Circulation Research · doi:10.1161/01.res.65.2.483 · Cited by 344
From 'Emax' to pressure-volume relations: a broader view.
Kass, D. A., & Maughan, W. L. (1988) · Circulation · doi:10.1161/01.cir.77.6.1203 · Cited by 329
Instantaneous pressure-volume relationship of the canine right ventricle.
Maughan, W. L., Shoukas, A. A., Sagawa, K., & Weisfeldt, M. L. (1979) · Circulation Research · doi:10.1161/01.res.44.3.309 · Cited by 313
Influence of contractile state on curvilinearity of in situ end-systolic pressure-volume relations.
Kass, D. A., Beyar, R., Lankford, E., Heard, M., Maughan, W. L., & Sagawa, K. (1989) · Circulation · doi:10.1161/01.cir.79.1.167 · Cited by 268
Contractility-dependent curvilinearity of end-systolic pressure-volume relations
Burkhoff, D., Sugiura, S., Yue, D. T., & Sagawa, K. (1987) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1987.252.6.h1218 · Cited by 234
Takeuchi, M., Igarashi, Y., Tomimoto, S., Odake, M., Hayashi, T., Tsukamoto, T., Hata, K., Takaoka, H., & Fukuzaki, H. (1991) · Circulation · doi:10.1161/01.cir.83.1.202 · Cited by 202
Effect of arterial impedance changes on the end-systolic pressure-volume relation.
Maughan, W. L., Sunagawa, K., Burkhoff, D., & Sagawa, K. (1984) · Circulation Research · doi:10.1161/01.res.54.5.595 · Cited by 182
Ventriculo-arterial coupling: Concepts, assumptions, and applications
Kass, D. A., & Kelly, R. P. (1992) · Annals of Biomedical Engineering · doi:10.1007/bf02368505 · Cited by 177
Estimation of the Hydromotive Source Pressure from Ejecting Beats of the Left Ventricle
Sunagawa, K., Yamada, A., Senda, Y., Kikuchi, Y., Nakamura, M., Shibahara, T., & Nose, Y. (1980) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.1980.326737 · Cited by 176
van der Velde, E. T., Burkhoff, D., Paul Steendijk, A., Karsdon, J., SAGAWA, K., & Baan, J. (1991) · Circulation · doi:10.1161/01.cir.83.1.315 · Cited by 152
Little, W. C., Cheng, C. P., Peterson, T., & Vinten-Johansen, J. (1988) · Circulation · doi:10.1161/01.cir.78.3.736 · Cited by 143
Influence of contractile state on curvilinearity of in situ end-systolic pressure-volume relations.
AKass, D., RBeyar, ELankford, et al. (1989) · Circulation · Cited by 131
Assessment of right ventricular contractile state with the conductance catheter technique in the pig
Dickstein, M. L., Yano, O. J., Spotnitz, H. M., et al. (1995) · Cardiovascular Research · doi:10.1016/s0008-6363(96)88618-4 · Cited by 102
Effects of low flow on pulmonary vascular flow–pressure curves and pulmonary vascular impedance
Brimioulle, S. (1999) · Cardiovascular Research · doi:10.1016/s0008-6363(98)00301-0 · Cited by 51
Self-citationThe Anrep effect: an intrinsic myocardial mechanism
Nichols, C. G., Hanck, D. A., & Jewell, B. R. (1988) · Canadian Journal of Physiology and Pharmacology · doi:10.1139/y88-150 · Cited by 40
Cardozo, R. H. L., Paul Steendijk, A., Baan, J., BROUWERS, H. A. A., de Vroomen, M., & van Bel, F. (2000) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.162.2.9906114 · Cited by 26
Validation and utility of novel volume reduction technique for determination of parallel conductance
White, P. A., Brookes, C. I. O., Ravn, H. B., Hjortdal, V. E., Chaturvedi, R. R., & Redington, A. N. (2001) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2001.280.1.h475 · Cited by 10
Cited by
Haddad, F., Hunt, S. A., Rosenthal, D. N., & Murphy, D. J. (2008) · Circulation · doi:10.1161/circulationaha.107.653576 · Cited by 1,523
The Relationship Between the Right Ventricle and its Load in Pulmonary Hypertension
Vonk Noordegraaf, A., Westerhof, B. E., & Westerhof, N. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.10.047 · Cited by 780
Anatomy, Function, and Dysfunction of the Right Ventricle
Sanz, J., Sánchez-Quintana, D., Bossone, E., Bogaard, H. J., & Naeije, R. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.12.076 · Cited by 727
Self-citationTello, K., Wan, J., Dalmer, A., Vanderpool, R., Ghofrani, H. A., Naeije, R., Roller, F., Mohajerani, E., Seeger, W., Herberg, U., et al. (2019) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.119.009047 · Cited by 599
Self-citationVonk Noordegraaf, A., Chin, K. M., Haddad, F., Hassoun, P. M., Hemnes, A. R., Hopkins, S. R., Kawut, S. M., Langleben, D., Lumens, J., & Naeije, R. (2019) · European Respiratory Journal · doi:10.1183/13993003.01900-2018 · Cited by 569
Self-citation
Metadata
- Authors
- Brimioulle, S., Wauthy, P., Ewalenko, P., Rondelet, B., Vermeulen, F., Kerbaul, F., & Naeije, R.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2003-05-01
- Volume
- 284
- Issue
- 5
- Pages
- H1625-H1630
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2146971940
- Cited by
- 346
- References
- 23
- FWCI
- 3.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.