Comparison of simultaneous measurement of mouse systolic arterial blood pressure by radiotelemetry and tail-cuff methods
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Radiotelemetry of mouse blood pressure accurately monitors systolic pressure, diastolic pressure, heart rate, and locomotor activity but requires surgical implantation. Noninvasive measurements of indirect systolic blood pressure have long been available for larger rodents and now are being reported more frequently for mice. This study compared mouse systolic arterial blood pressure measurements using implanted radiotelemetry pressure transducer with simultaneous tail-cuff measurements in the same unanesthetized mice. The pressure range for comparison was extended by inducing experimental hypertension or by observations of circadian elevations between 3 AM and 6 AM. Both trained and untrained tail-cuff operators used both instruments. Every effort was made to follow recommended manufacturer's instructions. With the initial flow-based tail-cuff instrument, we made 671 comparisons (89 sessions) and found the slope of the linear regression to be 0.118, suggesting poor agreement. In an independent assessment, 277 comparisons (35 sessions) of radiotelemetry measurements with the pulse based tail-cuff instrument were made. The slope of the linear regression of the simultaneous measurements of systolic pressures was 0.98, suggesting agreement. Bland-Altman analysis also supported our interpretation of the linear regression. Thus although reliable systolic pressure measurements are possible with either tail-cuff or radiotelemetry techniques, in our hands some tail-cuff instruments fail to accurately detect elevated blood pressures. These data, however, do not distinguish whether this instrument-specific tail-cuff failure was due to operator or instrument inadequacies. We strongly advise investigators to obtain an independent and simultaneous validation of tail-cuff determinations of mouse blood pressure before making critical genotyping determinations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Measurement in Medicine: The Analysis of Method Comparison Studies
Altman, D. G., & Bland, J. M. (1983) · The Statistician · doi:10.2307/2987937 · Cited by 4,300
A Noninvasive Computerized Tail-Cuff System for Measuring Blood Pressure in Mice
Krege, J. H., Hodgin, J. B., Hagaman, J. R., & Smithies, O. (1995) · Hypertension · doi:10.1161/01.hyp.25.5.1111 · Cited by 587 · cited 10×
“Krege (11) reported the measurement of mouse pressures by tail-cuff and intravascular catheter and concluded there was an acceptable agreement.”
BackgroundMethodInfluentialBUTZ, G. M., & DAVISSON, R. L. (2001) · Physiological Genomics · doi:10.1152/physiolgenomics.2001.5.2.89 · Cited by 279 · cited 1×
“Butz and Davisson (4) reported success with radiotelemetry on mice as small as 17 g (average 22 g) and female mice instrumented before and monitored during and after pregnancy.”
BackgroundEvaluation and applications of radiotelemetry in small laboratory animals
Kramer, K., & Kinter, L. B. (2003) · Physiological Genomics · doi:10.1152/physiolgenomics.00164.2002 · Cited by 221
Mills, P. A., Huetteman, D. A., Brockway, B. P., Zwiers, L. M., Gelsema, A. J. M., Schwartz, R. S., & Kramer, K. (2000) · Journal of Applied Physiology · doi:10.1152/jappl.2000.88.5.1537 · Cited by 173 · cited 5×
“(16), and they concluded it to be more efficient, reliable, and less labor intensive than either tail-cuff or exteriorized methods for mouse blood pressure.”
BackgroundMethodInfluentialModels of Experimental Hypertension in Mice
Johns, C., Gavras, I., Handy, D. E., Salomao, A., & Gavras, H. (1996) · Hypertension · doi:10.1161/01.hyp.28.6.1064 · Cited by 172 · cited 3×
“Much of the previous arterial pressure data obtained for the mouse used tail-cuff procedures or carotid artery cannulation in anesthetized or restrained animals (7, 11, 17).”
BackgroundMethodCircadian blood pressure and heart rate rhythms in mice
Li, P., Sur, S. H., Mistlberger, R. E., & Morris, M. (1999) · American Journal of Physiology-Regulatory, Integrative and Comparative Physiology · doi:10.1152/ajpregu.1999.276.2.r500 · Cited by 117 · cited 1×
“Additionally, because parameters are sampled continuously, changes in circadian rhythm (12) associated with specific pathologies or pharmacological manipulations can be more readily determined.”
Background
Cited by
Adiponectin Replenishment Ameliorates Obesity-Related Hypertension
Ohashi, K., Kihara, S., Ouchi, N., Kumada, M., Fujita, K., Hiuge, A., Hibuse, T., Ryo, M., Nishizawa, H., Maeda, N., et al. (2006) · Hypertension · doi:10.1161/01.hyp.0000222368.43759.a1 · Cited by 400
Validation of Volume-Pressure Recording Tail-Cuff Blood Pressure Measurements
Feng, M., Whitesall, S., Zhang, Y., Beibel, M., Alecy, L. D., & DiPetrillo, K. (2008) · American Journal of Hypertension · doi:10.1038/ajh.2008.301 · Cited by 327
Self-citationCong, P., Chaimanonart, N., Ko, W. H., & Young, D. J. (2009) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2009.2035551 · Cited by 190
“The most common technique for monitoring blood pressure in small laboratory animals relies on using an invasive catheter-tip transducer inserted into an artery [3] or a tail cuff device [ 4 ].”
MethodLeelahavanichkul, A., Yan, Q., Hu, X., Eisner, C., Huang, Y., Chen, R., Mizel, D., Zhou, H., Wright, E. C., Kopp, J. B., et al. (2010) · Kidney International · doi:10.1038/ki.2010.287 · Cited by 167
Dolinsky, V. W., Rogan, K. J., Sung, M. M., Zordoky, B. N., Haykowsky, M. J., Young, M. E., Jones, L. W., & Dyck, J. R. B. (2013) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.00044.2013 · Cited by 133
Szalai, G., Romero, R., Chaiworapongsa, T., Xu, Y., Wang, B., Ahn, H., Xu, Z., Chiang, P. J., Sundell, B., Wang, R., et al. (2015) · PLoS ONE · doi:10.1371/journal.pone.0119547 · Cited by 46
“Among blood pressure monitoring systems utilized in previous rodent preeclampsia models, the telemetric blood pressure monitoring system offers several advantages over non-invasive systems, including the tail-cuff method [197,199,224].”
MethodMotor and cognitive deficits in mice bred to have low or high blood pressure
Hartman, R. E., Kamper, J. E., Goyal, R., Stewart, J. M., & Longo, L. D. (2012) · Physiology & Behavior · doi:10.1016/j.physbeh.2011.11.022 · Cited by 25
Shah, A., Coburn, C. G., Watson-Siriboe, A., Whitley, R., Shahidzadeh, A., Gillard, E. R., Nichol, R., Leon-Olea, M., Gaertner, M., Kodavanti, P. R. S., et al. (2011) · Toxicology and Applied Pharmacology · doi:10.1016/j.taap.2011.07.014 · Cited by 24
Sofer, Y., Nevo, N., Vechoropoulos, M., Shefer, G., Osher, E., Landis, N., Tordjman, K., Hammond, G. L., & Stern, N. (2018) · Endocrine Connections · doi:10.1530/ec-17-0240 · Cited by 6
Metadata
- Authors
- Whitesall, S. E., Hoff, J. B., Vollmer, A. P., & D'Alecy, L. G.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 2004-06
- Volume
- 286
- Issue
- 6
- Pages
- H2408-H2415
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W2106475006
- Cited by
- 217
- References
- 18
- FWCI
- 5.37
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.