The DOI matches its Crossref record.
Transfer function analysis of autonomic regulation. I. Canine atrial rate response
Abstract
We present a useful technique for analyzing the various functional components that comprise the cardiovascular control network. Our approach entails the imposition of a signal with broad frequency content as an input excitation and the computation of a system transfer function using spectral estimation techniques. In this paper, we outline the analytical methods involved and demonstrate the utility of our approach in studying the dynamic behavior of the canine cardiac pacemaker. In particular, we applied frequency-modulated pulse trains to either the right vagus or the cardiac sympathetic nerve and computed transfer functions between nerve stimulation rate and the resulting atrial rate. We found that the sinoatrial node (and associated automatic tissue) responds as a low-pass filter to fluctuations in either sympathetic or parasympathetic tone. For sympathetic fluctuations, however, the filter has a much lower corner frequency than for vagal fluctuations and is coupled with a roughly 1.7-s pure delay. We further found that the filter characteristics, including the location of the corner frequency and rate of roll-off, depend significantly on the mean level of sympathetic or vagal tone imposed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Heart rate variability: Standards of measurement, physiological interpretation, and clinical use
Malik, M., Bigger, J. T., Camm, A. J., Kleiger, R. E., Malliani, A., Moss, A. J., & Schwartz, P. J. (1996) · European Heart Journal · doi:10.1093/oxfordjournals.eurheartj.a014868 · Cited by 15,289
Heart rate variability: origins, methods, and interpretive caveats
BERNTSON, G. G., THOMAS BIGGER, J., ECKBERG, D. L., GROSSMAN, P., KAUFMANN, P. G., MALIK, M., NAGARAJA, H. N., PORGES, S. W., SAUL, J. P., STONE, P. H., et al. (1997) · Psychophysiology · doi:10.1111/j.1469-8986.1997.tb02140.x · Cited by 3,962
Self-citationGrossman, P., & Taylor, E. W. (2007) · Biological Psychology · doi:10.1016/j.biopsycho.2005.11.014 · Cited by 1,133
BERNTSON, G. G., CACIOPPO, J. T., & QUIGLEY, K. S. (1993) · Psychophysiology · doi:10.1111/j.1469-8986.1993.tb01731.x · Cited by 998
Parati, G., Saul, J. P., Di Rienzo, M., & Mancia, G. (1995) · Hypertension · doi:10.1161/01.hyp.25.6.1276 · Cited by 849
Self-citationBerntson, G. G., Cacioppo, J. T., & Quigley, K. S. (1991) · Psychological Review · doi:10.1037/0033-295x.98.4.459 · Cited by 819
Accuracy of assessment of cardiac vagal tone by heart rate variability in normal subjects.
Hayano, J., Sakakibara, Y., Yamada, A., Yamada, M., Mukai, S., Fujinami, T., Yokoyama, K., Watanabe, Y., & Takata, K. (1991) · The American Journal of Cardiology · doi:10.1016/0002-9149(91)90445-q · Cited by 746
Heart Rate Turbulence: Standards of Measurement, Physiological Interpretation, and Clinical Use
Bauer, A., Malik, M., Schmidt, G., Barthel, P., Bonnemeier, H., Cygankiewicz, I., Guzik, P., Lombardi, F., Müller, A., Oto, A., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2008.07.041 · Cited by 462
Berntson, G. G., Cacioppo, J. T., & Quigley, K. S. (1993) · Psychological Bulletin · doi:10.1037/0033-2909.114.2.296 · Cited by 430
Neural influences on cardiovascular variability: possibilities and pitfalls.
Malpas, S. C. (2002) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2002.282.1.h6 · Cited by 408
Quintana, D. S., Guastella, A. J., Outhred, T., Hickie, I. B., & Kemp, A. H. (2012) · International Journal of Psychophysiology · doi:10.1016/j.ijpsycho.2012.08.012 · Cited by 367
Pitfalls of assessment of autonomic function by heart rate variability
Hayano, J., & Yuda, E. (2019) · Journal of Physiological Anthropology · doi:10.1186/s40101-019-0193-2 · Cited by 349
Parati, G., Mancia, G., Rienzo, M. D., & Castiglioni, P. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00446.2006 · Cited by 325
Autonomic space and psychophysiological response
BERNTSON, G. G., CACIOPPO, J. T., QUIGLEY, K. S., & FABRO, V. T. (1994) · Psychophysiology · doi:10.1111/j.1469-8986.1994.tb01024.x · Cited by 289
Taylor, J. A., Myers, C. W., Halliwill, J. R., Seidel, H., & Eckberg, D. L. (2001) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.2001.280.6.h2804 · Cited by 249
Dynamic coupling between the central and autonomic nervous systems during sleep: a review
de Zambotti, M., Trinder, J., Silvani, A., Colrain, I. M., & Baker, F. C. (2018) · Neuroscience & Biobehavioral Reviews · doi:10.1016/j.neubiorev.2018.03.027 · Cited by 194
Dynamic nonlinear vago-sympathetic interaction in regulating heart rate
Sunagawa, K., Kawada, T., & Nakahara, T. (1998) · Heart and Vessels · doi:10.1007/bf01745040 · Cited by 119
Entrainment of Blood Pressure and Heart Rate Oscillations by Periodic Breathing
LORENZI-FILHO, G., DAJANI, H. R., LEUNG, R. S. T., FLORAS, J. S., & BRADLEY, T. D. (1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.4.9806081 · Cited by 105
Sympathetic control of short-term heart rate variability and its pharmacological modulation.
Elghozi, J., & Julien, C. (2007) · Fundamental & Clinical Pharmacology · doi:10.1111/j.1472-8206.2007.00502.x · Cited by 97
Perceiving blocks of emotional pictures and sounds: effects on physiological variables.
Brouwer, A.-M., van Wouwe, N., Mühl, C., van Erp, J., & Toet, A. (2013) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2013.00295 · Cited by 85
Yeragani, V. K., Krishnan, S., Engels, H. J., & Gretebeck, R. (2005) · Depression and Anxiety · doi:10.1002/da.20061 · Cited by 74
Effects of respiratory time ratio on heart rate variability and spontaneous baroreflex sensitivity
Wang, Y.-P., Kuo, T. B. J., Lai, C.-T., Chu, J.-W., & Yang, C. C. H. (2013) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00163.2013 · Cited by 56
Robert, J. J. T., Orr, W. C., & Elsenbruch, S. (2004) · Digestive Diseases and Sciences · doi:10.1023/b:ddas.0000037820.54069.6c · Cited by 51
Relationship between cardiac cycle and the timing of actions during action execution and observation
Palser, E. R., Glass, J., Fotopoulou, A., & Kilner, J. M. (2021) · Cognition · doi:10.1016/j.cognition.2021.104907 · Cited by 37
Introduction to Heart Rate Variability
Hayano, J. (2017) · Clinical Assessment of the Autonomic Nervous System · doi:10.1007/978-4-431-56012-8_7 · Cited by 20
Chen, C.-L., Tang, J.-S., Li, P.-C., & Chou, P.-L. (2015) · Frontiers in Physiology · doi:10.3389/fphys.2015.00376 · Cited by 20
Metadata
- Authors
- Berger, R. D., Saul, J. P., & Cohen, R. J.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1989-01-01
- Volume
- 256
- Issue
- 1
- Pages
- H142-H152
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W1829725583
- Cited by
- 501
- References
- 0
- FWCI
- 4.90
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.