Subcellular distribution of shear stress at the surface of flow-aligned and nonaligned endothelial monolayers
The DOI matches its Crossref record.
Abstract
The stresses acting on the luminal surface of endothelial cells due to shear flow were determined on a subcellular scale. Atomic force microscopy was used to measure the surface topography of confluent endothelial monolayers cultured under no-flow conditions or exposed to steady shear stress (12 dyn/cm2 for 24 h). Flow over these surface geometries was simulated by computational fluid dynamics, and the distribution of shear stress on the cell surface was calculated. Flow perturbations due to the undulating surface produced cell-scale variations of shear stress magnitude and hence large shear stress gradients. Reorganization of the endothelial surface in response to prolonged exposure to steady flow resulted in significant reductions in the peak shear stresses and shear stress gradients. From the relationship between surface geometry and the resulting shear stress distribution, we have defined a hydrodynamic shape factor that characterizes the three-dimensional morphological response of endothelial cells to flow. The analysis provides a complete description of the spatial distribution of stresses on individual endothelial cells within a confluent monolayer on a scale relevant to the study of physical mechanisms of mechanotransduction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Flow-mediated endothelial mechanotransduction
Davies, P. F. (1995) · Physiological Reviews · doi:10.1152/physrev.1995.75.3.519 · Cited by 2,802
Self-citationChiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280
“(134) demonstrate by DNA microarray studies that ECs isolated from disturbed flow regions exhibit a greater degree of heterogeneity in gene expression than those from laminar flow regions and that the heterogeneity in disturbed flow regions may contribute to the focal initiation of atherosclerotic lesions (27, 130, 13…”
BackgroundHemodynamic shear stress and the endothelium in cardiovascular pathophysiology
Davies, P. F. (2009) · Nature Clinical Practice Cardiovascular Medicine · doi:10.1038/ncpcardio1397 · Cited by 1,209
Self-citationThe role of shear stress in the pathogenesis of atherosclerosis
Cunningham, K. S., & Gotlieb, A. I. (2005) · Laboratory Investigation · doi:10.1038/labinvest.3700215 · Cited by 1,151
Laminar Shear Stress: Mechanisms by Which Endothelial Cells Transduce an Atheroprotective Force
Traub, O., & Berk, B. C. (1998) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.18.5.677 · Cited by 1,085
Cytoskeletal regulation of pulmonary vascular permeability
Dudek, S. M., & Garcia, J. G. N. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.4.1487 · Cited by 985
Molecular basis of the effects of shear stress on vascular endothelial cells
Li, Y.-S. J., Haga, J. H., & Chien, S. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.030 · Cited by 904
Endothelial Dysfunction: Does It Matter? Is It Reversible?
Celermajer, D. S. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00189-7 · Cited by 681
Fluid shear stress and the vascular endothelium: for better and for worse
Resnick, N., Yahav, H., Shay-Salit, A., Shushy, M., Schubert, S., Zilberman, L. C. M., & Wofovitz, E. (2003) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(02)00052-4 · Cited by 577
Shear stress and the endothelium
Ballermann, B. J., Dardik, A., Eng, E., & Liu, A. (1998) · Kidney International · doi:10.1046/j.1523-1755.1998.06720.x · Cited by 439
Reneman, R. S., Arts, T., & Hoeks, A. P. G. (2006) · Journal of Vascular Research · doi:10.1159/000091648 · Cited by 431
Biomechanical activation: an emerging paradigm in endothelial adhesion biology.
Gimbrone, M. A., Nagel, T., & Topper, J. N. (1997) · Journal of Clinical Investigation · doi:10.1172/jci119346 · Cited by 347
SPATIAL RELATIONSHIPS IN EARLY SIGNALING EVENTS OF FLOW-MEDIATED ENDOTHELIAL MECHANOTRANSDUCTION
Davies, P. F., Barbee, K. A., Volin, M. V., Robotewskyj, A., Chen, J., Joseph, L., Griem, M. L., Wernick, M. N., Jacobs, E., Polacek, D. C., et al. (1997) · Annual Review of Physiology · doi:10.1146/annurev.physiol.59.1.527 · Cited by 322
Self-citationEndothelial Cell Sensing of Flow Direction
Wang, C., Baker, B. M., Chen, C. S., & Schwartz, M. A. (2013) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/atvbaha.113.301826 · Cited by 294
Structural adaptation and stability of microvascular networks: theory and simulations
Pries, A. R., Secomb, T. W., & Gaehtgens, P. (1998) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1998.275.2.h349 · Cited by 275
The shear stress of it all: the cell membrane and mechanochemical transduction
White, C. R., & Frangos, J. A. (2007) · Philosophical Transactions of the Royal Society B: Biological Sciences · doi:10.1098/rstb.2007.2128 · Cited by 255
Transient and Steady-State Effects of Shear Stress on Endothelial Cell Adherens Junctions
Noria, S., Cowan, D. B., Gotlieb, A. I., & Langille, B. L. (1999) · Circulation Research · doi:10.1161/01.res.85.6.504 · Cited by 252
Integration of substrate- and flow-derived stresses in endothelial cell mechanobiology
Dessalles, C. A., Leclech, C., Castagnino, A., & Barakat, A. I. (2021) · Communications Biology · doi:10.1038/s42003-021-02285-w · Cited by 230
Shear stress induces a time- and position-dependent increase in endothelial cell membrane fluidity
Butler, P. J., Norwich, G., Weinbaum, S., & Chien, S. (2001) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.2001.280.4.c962 · Cited by 229
“(5), but not with the absolute shear stress distributions.”
BackgroundIntimal Hyperplasia in Vascular Grafts
Lemson, M. S., Tordoir, J. H. M., Daemen, M. J. A. P., & Kitslaar, P. J. E. H. M. (2000) · European Journal of Vascular and Endovascular Surgery · doi:10.1053/ejvs.1999.1040 · Cited by 227
Bhatia, R., Lin, H., & Lal, R. (2000) · The FASEB Journal · doi:10.1096/fasebj.14.9.1233 · Cited by 226
Self-citationRecruitment of endothelial caveolae into mechanotransduction pathways by flow conditioning in vitro
Rizzo, V., Morton, C., DePaola, N., Schnitzer, J. E., & Davies, P. F. (2003) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00344.2002 · Cited by 218
Self-citationThe Role of Mechanical Stresses in Microvascular Remodeling
Skalak, T. C., & Price, R. J. (1996) · Microcirculation · doi:10.3109/10739689609148284 · Cited by 206
“(6) have applied atomic force microscopy in order to obtain local details of the endothelial cell surface topography with the goal of understanding possible shear stress response mechanisms.”
MethodMacromolecules at surfaces: Research challenges and opportunities from tribology to biology
Granick, S., Kumar, S. K., Amis, E. J., Antonietti, M., Balazs, A. C., Chakraborty, A. K., Grest, G. S., Hawker, C., Janmey, P., Kramer, E. J., et al. (2003) · Journal of Polymer Science Part B: Polymer Physics · doi:10.1002/polb.10669 · Cited by 184
Gaver, D. P., & Kute, S. M. (1998) · Biophysical Journal · doi:10.1016/s0006-3495(98)77562-9 · Cited by 171
“This aspect has been recognized and studied by Barbee and colleagues (Barbee et al., 1995), who used computational fluid dynamics tools to investigate how endothelial cell remodeling influences the subcellular shear stress distribution.”
BackgroundMechanotransduction in the renal tubule
Weinbaum, S., Duan, Y., Satlin, L. M., Wang, T., & Weinstein, A. M. (2010) · American Journal of Physiology-Renal Physiology · doi:10.1152/ajprenal.00453.2010 · Cited by 158
Metadata
- Authors
- Barbee, K. A., Mundel, T., Lal, R., & Davies, P. F.
- Venue
- American Journal of Physiology-Heart and Circulatory Physiology
- Publisher
- American Physiological Society
- Published
- 1995-04-01
- Volume
- 268
- Issue
- 4
- Pages
- H1765-H1772
- ISSN
- 0363-6135 (ISSN-L)
- 1522-1539
- OpenAlex
- W95733417
- Cited by
- 209
- References
- 0
- FWCI
- 3.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.